Installation
Lower the table down far enough so that you can
attach the cone. Power off the VersaLASER. By
hand, move the X-axis arm and Focus Carriage to
a comfortable working position in the field. Remove
(if present) the plug (1) with a screwdriver.
Using a 3/16 socket tool or 5mm wrench, attach the
needle valve to the port where you removed the
plug. Be careful not to cross-thread the small
device when installing and do not over tighten it.
Loosen the thumbscrew (1) on the side of the
Focus Carriage (if already attached). Insert the
cone (2) by pushing it straight up into the bottom of
the Focus Carriage ensuring that it is up all the way
and is seated properly, and gently tighten the
thumbscrew. If this is the first time using the cone,
open the needle valve (3) all the way, counter
clockwise. This will result in maximum airflow
through the cone. To lock the adjustment in place,
rotate the round locking nut (4) clockwise until it
seats.
Usage
Power on the VersaLASER and run a job. Make sure that the CCAC unit turns on (if purchased) or your
compressed air source is operating when the job starts processing. Observe how the smoke is pushed
away from the tip of the cone. If you would like to reduce the flow, pause the job and adjust the needle
valve as necessary.
NEVER install the Air Assist Cone without having the Computer Controlled Air
Compressor Unit installed and operating, and NEVER shut off the needle valve
completely. The lack of pressurized air present in the cone, during processing, will allow
smoke to contaminate the lens and can destroy it within seconds.
WARNING