Specifications

ACCESSORIES
Section 5-13
Power on the VersaLASER. Load some scrap
material of the same type you intend to process
and set focus using the Focus Tool. Adjust the
angle of the nozzle by loosening the thumbscrew
(1), rotating the bracket, and re-tightening the
thumbscrew. You can also adjust the height (2) by
loosening the mounting thumbscrew, making the
adjustment and re-tightening the thumbscrew. Use
the Red Dot pointer as your guide to where the
laser beam will strike the material.
WARNING: Since the Back Sweep hangs
downwards toward the surface of your material
and the surface of the table, ensure that the
motion of the Focus Carriage will not cause the
Back Sweep to mechanically interfere with your
material or components of the VersaLASER
otherwise serious damage may occur.
Usage
If this is the first time using the Back Sweep, open the needle valve all the way, counter clockwise. This
will result in maximum airflow. To lock the adjustment in place, rotate the round locking nut clockwise
until it seats.
Load and run a job. Make sure that the CCAC unit turns on (if purchased) or your compressed air source
is operating when the job starts processing. Observe how the smoke is being pushed away. If you would
like to reduce the flow or to change the angle or height of the airflow, pause the job and adjust as
necessary.
Removal
Remove the height adjustment thumbscrew and detach the Back Sweep from the mount. Re-attach the
thumbscrew to the mount so that it doesn’t get lost. Either detach the accessory by unscrewing the
needle valve and reinstalling the plug (the same way you installed it), or by the preferred method of un-
attaching the hose from the needle valve by either using a wrench to loosen the nut at the end of the hose
or by simply using the cone as your wrench and turning it counter clockwise. This way, the needle valve
remains attached to the Focus Carriage for the next time you install the accessory. The same needle
valve is also used for the Air Assist Cone accessory.