Specifications
Specifications
System Operating Environment Requirements (user provided)
Model VL-200 VL-300
Operating Environment Well-ventilated office (recommended)
or clean, light-duty manufacturing area
Operating Temperature 50ºF (10ºC) to 95ºF (35º C) capable
73ºF (22ºC) to 77ºF (25º C) for best performance
Storage Temperature 50ºF (10ºC) to 95ºF (35º C)
Operating Humidity Non-condensing
Electrical Power 110/220 VAC, 10/5A, Grounded 110/220 VAC, 10/5A, Grounded
Particulate/Odor Outside
Ventilated Exhaust System
High-pressure vacuum blower capable of
150 CFM (cubic feet per minute) @ 6 inches static pressure
(255m3/hr at 1.5kPa)
Computer Requirement Windows XP Home or Professional Editions
Available USB 1.1 port or higher
Software Requirement Any Windows based Graphics or CAD application
System Specifications
Laser Safety CO2 Laser, Interlocked Safety Enclosure = Class I
Red Diode Pointer = Class IIIa
Laser Source 25 or 30 watt CO2 Laser 30,40, or 50 watt CO2 Laser
Cooling Air Cooled
Work Area 16” x 12” (406.4 x 304.8 mm) 24” x 12” (609.6 x 304.8 mm)
Printer Driver Windows XP
Hardware Interface USB 1.1
Dimensions 26”Wide x 25” Deep x 14”Height
(660.4mm x 635mm x 355.6)
34”Wide x 25” Deep x 14”Height
(863.6mm x 635mm x 355.6)
System Weight System = 85 lbs. (38 kg) System = 100–106 lbs. (45-48 kg)
Laser Cartridge Weight 25/30 Watt = 20 lbs (9 kg)
40 Watt = 23 lbs (10 kg)
50 Watt = 26 lbs (12 kg)
Available Options Cart, Integrated Air Cleaner, Rotary Fixture, Air Assist, Compressed Air,
Cutting Table, Focus Lens Kits
Specifications subject to change without notice