Safety
Description of Appropriate Use
This device is designed for laser cutting and engraving of the materials listed in the VersaLASER printer
driver. Materials to be processed must fit completely inside the system for proper operation. Use of the
equipment in a manner other than that described in this manual may result in injury to yourself and others
and may cause severe damage to the equipment and your facility.
General Safety
• Exposure to the laser beam may cause physical burns and can cause severe eye damage.
Proper use and care of this system are essential to safe operation.
• Never operate the laser system without constant supervision of the cutting and engraving
process. Exposure to the laser beam may cause ignition of combustible materials and start a fire. A
properly maintained fire extinguisher should be kept on hand at all times.
• A properly configured, installed, maintained, and operating particulate/fume exhaust system is
mandatory when operating the laser system. Fumes and smoke from the engraving process must
be extracted from the laser system and either filtered through the Integrated Exhaust Filtration
Module (an optional accessory) or exhausted outside through a user supplied exhaust system.
• Some materials, during and after laser processing, may produce toxic fumes. We suggest that
you obtain the Material Safety Data Sheet (MSDS) from the materials manufacturer. The MSDS
discloses all of the hazards when handling or processing that material. Some materials continue
emitting fumes for several minutes after laser processing and may pose a health hazard. Avoid using
this device in small, enclosed, or non-ventilated areas.
• Some materials, during and after laser processing, may produce corrosive fumes.
DISCONTINUE processing any material that produces signs of chemical deterioration in the laser
system such as rust, metal etching or pitting, peeling paint, etc. Damage to the laser system from
corrosive materials is NOT covered under warranty.
• Care should be taken when moving or lifting this device. Obtain assistance from 1 or 2 additional
people when lifting or carrying (secure motion system and access door). Severe bodily injury may
occur if improper lifting techniques are applied or the system is dropped.
• Dangerous voltages are present within the electronics and laser enclosures of this system.
Although access to these areas is not necessary during normal use, if it becomes necessary to open
one of these enclosures for service reasons, please remember to disconnect the power cord from
your electrical supply.
• This device is specifically designed to comply with CDRH performance requirements under 21
CFR 1040.10 and 1040.11. CDRH is the Center for the Devices of Radiological Health division of the
Food and Drug Administration (FDA) in the USA. It also complies with CE (European Community)
safety regulations. No guarantees of suitability or safety are provided for any use other than those
specified by Universal Laser Systems, Inc.