Specifications
SAFETY
Section 1-2
Laser Safety
The device contains a sealed carbon dioxide (CO2) laser in a Class I enclosure that produces intense
invisible and visible laser radiation at a wavelength of 10.6 microns in the infrared spectrum. For your
protection, this enclosure is designed to completely contain the CO2 laser beam.
CAUTION – Use of controls or adjustments or performance of procedures other than those
specified herein may result in hazardous radiation exposure.
• The intense light that appears during the engraving or cutting process is the product of material
combustion or vaporization. DO NOT STARE AT THIS LIGHT FOR EXTENDED PERIODS OR
ATTEMPT TO VIEW IT WITH OPTICAL INSTRUMENTS.
• This device contains a visible Red Dot Pointer (Class IIIa, 5mw maximum output, 630-680 nm). DO
NOT STARE AT THIS RED LIGHT FOR EXTENDED PERIODS OR ATTEMPT TO VIEW IT WITH
OPTICAL INSTRUMENTS.
• The user access door of this device is safety interlocked and will disable the CO2 laser beam when
the access door is opened. The Red Dot Pointer is NOT safety interlocked and is activated when the
user access door is open.
• DO NOT OPERATE THE LASER SYSTEM IF ITS SAFETY FEATURES HAVE BEEN MODIFIED,
DISABLED OR REMOVED. This may lead to exposure to invisible and visible CO2 laser radiation
which may cause permanent blindness and/or severe burns to the skin.
Safety Labels
CDRH and CE regulations require that all laser manufacturers affix warning labels in specific locations
throughout the equipment. The following warning labels are placed on the laser system for your safety.
DO NOT remove them for any reason. If the labels become damaged or are removed for any reason, DO
NOT OPERATE the laser system and immediately contact Universal Laser Systems, Inc. for free
replacements. Labels are NOT to scale.
Model No:
Serial No:
Made in USA
Manufactured:
Scottsdale, Arizona
WARNING
NEVER OPERATE THE LASER SYSTEM
WITHOUT CONSTANT SUPERVISION
EXPOSURE TO THE LASER BEAM MAY
CAUSE IGNITION OF COMBUSTIBLE
MATERIALS WHICH CAN CAUSE SEVERE
DAMAGE TO THE EQUIPMENT
THIS EQUIPMENT CONFORMS
TO PROVISIONS OF
US 21 CFR 1040.10
AND 1040.11
221-0002-0 221-0012-0 221-0015-0
DANGER
INVISIBLE AND VISIBLE LASER RADIATION
AND INTERLOCK FAILED OR
AVOID EYE OR SKIN EXPOSURE
DIRECT OR SCATTERED RADIATION
WHEN OPEN
DEFEATED
TO
DANGER
INVISIBLE AND VISIBLE LASER
RADIATION WHEN OPEN
AVOID EYE OR SKIN EXPOSURE TO
DIRECT OR SCATTERED RADIATION
AVOID EXPOSURE
INVISIBLE LASER RADIATION IS
EMITTED FROM THIS APERTURE
221-0016-0 221-0017-0 221-0018-0
WARNING
TO AVOID RISK OF ELECTRIC SHOCK
ALWAYS DISCONNECT POWER CORD
BEFORE REMOVING THIS COVER
INPUT POWER:
110 VAC; 50/60 Hz; 10 A