UPG Data Sheet

Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe
operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certied. U.L. recognized
under le number MH 20567.
Sealed Lead-Acid Battery
L: 10.13 in (257 mm)
W: 6.63 in (168 mm)
H: 6.89 in (175 mm)
TH: 7.00 in (178 mm)
Tolerances are +/- 0.04 in. (+/- 1mm)
and +/- 0.08 in. (+/- 2mm) for height
dimensions. All data subject to
change without notice.
Nominal Voltage
Nominal Capacity
20-hr. (3.00 A)
10-hr. (5.58 A)
5-hr. (10.2 A)
1-hr. (36.0 A)
Approximate Weight
Internal Resistance (approx.)
Shelf Life (% of normal capacity at 68º F (20º C)
3 Months 6 Months 12 Months
Temperature Dependancy of Capacity
104º F 77º F
12 volts
60.0 Ah
18.0 A or smaller
14.6 - 14.8 V
77º F (25º C)
(20 hour rate)
55.8 Ah
51.0 Ah
36.0 Ah
38.1 lbs (17.3 kgs)
6 m1
91% 83% 64%
102% 100% 85%
32º F 5º F
Charge Method
65%
(Constant Voltage)
Cycle Use
Float Use
Initial Current
Control Voltage
13.6 - 13.8 V
Control Voltage
(Repeating Use)
Specification
Physical Dimensions: in (mm)
Terminals
UPG No. 40503
Maintenance-Free
Group 34
10.13 (257)
6.63 (168)
6.89 (175)
7.00 (178)
5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 5HR 8HR 10HR 20HRF.V/Time
169.9 140.2 110.12 66.98 37.05 22.27 16.78 10.76 6.94 5.786 3.0379.60V
164.8 136.0 107.92 65.64 36.31 22.16 16.70 10.71 6.91 5.757 3.0229.90V
161.4 133.2 105.72 64.30 35.57 21.95 16.53 10.60 6.88 5.734 3.01010.2V
152.0 129.0 102.42 62.29 34.46 21.73 16.36 10.50 6.86 5.717 3.00110.5V
139.3 125.2 100.43 61.08 33.79 21.51 16.20 10.39 6.84 5.700 2.99310.8V
Constant Current Discharge Characteristics Unit:A (25°C, 77°F)
5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 5HR 8HR 10HR 20HRF.V/Time
1834 1531 1222 751 422.4 257.9 197.3 127.2 83.3 69.1 36.459.60V
1779 1485 1185 736 413.9 256.7 196.3 126.6 82.9 68.7 36.279.90V
1743 1455 1161 721 405.5 254.1 194.4 125.3 82.6 68.5 36.1310.2V
1642 1409 1125 699 392.8 251.6 192.4 124.1 82.3 68.3 36.0210.5V
1504 1367 1103 685 385.2 249.0 190.5 122.8 82.1 68.1 35.9110.8V
Constant Power Discharge Characteristics Unit:W (25°C, 77°F)
AGM Operational Temperature
AGM Storage Temperature
(0 C to 40 C)32 F to 104 F
5 F to 113 F
5 F to 104 F
(-15 C to 45 C)
Charge
Discharge
(-15 C to 40 C)
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com
www.upgi.com
All specifications subject to change without notice.
A1503-1
Due to continuous improvements to our products, product may vary slightly from depiction.
Copyright 2016 Universal Power Group Inc. All rights reserved.

Summary of content (2 pages)