UPG Data Sheet
Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe
operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certied. U.L. recognized under
le number MH 20567.
Sealed Lead-Acid Battery
Nominal Voltage
Nominal Capacity
20-hr. (0.75A)
10-hr. (1.40A)
5-hr. (2.55A)
1-hr. (9.00A)
Approximate Weight
12 volts (6 cells)
15.0 Ah
14.0 Ah
12.8 Ah
9.00 Ah
9.2 lbs. (4.2 kg)
www.upgi.com
Specification
Physical Dimensions: in (mm)
Terminals
J2030-1
UPG No. 40658
Maintenance-Free
UB12150
Shelf Life (% of normal capacity at 68º F (20º C)
3 Months 6 Months 12 Months
91% 83% 64%
12.8
0.31 inch tab with a
hole for a 4mm screw
7.8 5.00 4.00
D
TP
(Thread Pitch)
D
0.70
TP
Internal Resistance (approx.)
4.5 A or smaller
14.6 - 14.8 V
18m1
102% 100% 85%
Charge Method
65%
(Constant Voltage)
Cycle Use
Float Use
Initial Current
Control Voltage
13.6 - 13.8 V
Control Voltage
(Repeating Use)
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com
All specications are subject to change without notice.
AGM Operational Temperature
AGM Storage Temperature
(0 C to 40 C)32 F to 104 F
5 F to 113 F
5 F to 104 F
(-15 C to 45 C)
Charge
Discharge
(-15 C to 40 C)
Discharge Characteristics
(Minute) (Hour)
Discharge time
Cell voltage (V/Cell)
Discharge Time vs. Discharge Current
Discharge Current = CA X Nominal Capacity
(Minute)
(Hour)
Duration of Discharge
Due to continuous improvements to our products, product may vary slightly from depiction.
Copyright 2020 Universal Power Group. All rights reserved.
Temperature Dependency of Capacity
104 F (40 C) 77 F (25 C)
(20 hour rate)
32 F (0 C) 5 F (-15 C)
L: 6.00 in (152 mm)
W: 3.90 in (99.0 mm)
H: 3.80 in (96.0 mm)
TH: 4.10 in (104 mm)
Tolerances are +/- 0.04 in. (+/- 1mm)
and +/- 0.08 in. (+/- 2mm) for height
dimensions. All data subject to
change without notice.
6.00 (152)
3.80 (96.0)
4.10 (104)
3.90 (99.0)