UPG Data Sheet
Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe
operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certied. U.L. recognized
under le number MH 20567.
Sealed Lead-Acid Battery
Nominal Voltage
Nominal Capacity
20-hr. (0.75A)
10-hr. (1.40A)
5-hr. (2.55A)
1-hr. (9.00A)
Approximate Weight
12 volts (6 cells)
15.0 Ah
13.9 Ah
12.8 Ah
9.00 Ah
8.5 lbs. (3.85 kg)
L: 6.00 in (152 mm)
W: 3.90 in (99.0 mm)
H: 3.80 in (96.0 mm)
TH: 4.10 in (104 mm)
Tolerances are +/- 0.04 in. (+/- 1mm)
and +/- 0.08 in. (+/- 2mm) for height
dimensions. All data subject to
change without notice.
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com
www.upgi.com
Specification
Physical Dimensions: in (mm)
Terminals
D1927-1
UPG No. 40672
Maintenance-Free
UB12150
Shelf Life (% of normal capacity at 68º F (20º C)
3 Months 6 Months 12 Months
91% 83% 64%
6.00 (152)
3.80 (96.0)
4.10 (104)
3.90 (99.0)
4.5 A or smaller
14.6 - 14.8 V
13.6 - 13.8 V
All specifications are subject to change without notice.
Temperature Dependancy of Capacity
104 F (40 C) 77 F (25 C)
(20 hour rate)
102% 100% 85%
32 F (0 C) 5 F (-15 C)
65%
AGM Operational Temperature
AGM Storage Temperature
(0 C to 40 C)32 F to 104 F
5 F to 113 F
5 F to 104 F
(-15 C to 45 C)
Charge
Discharge
(-15 C to 40 C)
Discharge Characteristics
(Minute) (Hour)
Discharge time
Cell voltage (V/Cell)
Discharge Time vs. Discharge Current
Discharge Current = CA X Nominal Capacity
(Minute)
(Hour)
Duration of Discharge
Copyright 2019 Universal Power Group, Inc. All rights reserved.
Due to continuous improvements to our products, product may vary slightly from depiction.
6.4 mm
0.25 in
8.2 mm
0.32 in
.8 mm
0.03 in
7.9 mm
0.31in