UPG Specification sheet

20-hr. (0.45A)
10-hr. (0.83A)
5-hr. (1.54A)
1-hr. (5.40A)
Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe
operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certied. U.L. recognized under le
number MH 20567.
Sealed Lead-Acid Battery
L: 5.94 in (151 mm)
W: 2.56 in (65.0 mm)
H: 3.78 in (96.0 mm)
TH: 4.06 in (103 mm)
Tolerances are +/- 0.04 in. (+/- 1mm)
and +/- 0.08 in. (+/- 2mm) for height
dimensions. All data subject to
change without notice.
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com
www.upgi.com
Nominal Voltage
Nominal Capacity
Approximate Weight
Internal Resistance (approx.)
Shelf Life (% of normal capacity at 68º F (20º C)
3 Months 6 Months 12 Months
12 volts
9.00 Ah
77º F (25º C)
8.30 Ah
7.69 Ah
5.40 Ah
5.17 lbs (2.35 kgs)
19m
91% 83% 64%
2.7 A or smaller
14.6 - 14.8 V
Charge Method (Constant Voltage)
Cycle Use
Float Use
Initial Current
Control Voltage
13.6 - 13.8 V
Control Voltage
(Repeating Use)
Specification
Physical Dimensions: in (mm)
Terminals
J2021-1
All specifications are subject to change without notice.
UPG No. 40749
Maintenance-Free
UB1290
2.56 (65.0)
5.94 (151)
3.78 (96.0)
4.06 ( 103)
Temperature Dependancy of Capacity
104 F (40 C) 77 F (25 C)
(20 hour rate)
102% 100% 85%
32 F (0 C) 5 F (-15 C)
65%
AGM Operational Temperature
AGM Storage Temperature
(0 C to 40 C)32 F to 104 F
5 F to 113 F
5 F to 104 F
(-15 C to 45 C)
Charge
Discharge
(-15 C to 40 C)
Copyright 2020 Universal Power Group. All rights reserved.
Due to continuous improvements to our products, product may vary slightly from depiction.
Discharge Characteristics
(Minute) (Hour)
Discharge time
Cell voltage (V/Cell)
Discharge Time vs. Discharge Current
Discharge Current = CA X Nominal Capacity
(Minute)
(Hour)
Duration of Discharge

Summary of content (2 pages)