UPG Data Sheet

Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction
allows safe operation in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certied.
U.L. recognized under le number MH 20567.
L: 6.57 in (167 mm)
W: 6.89 in (175 mm)
H: 5.04 in (128 mm)
TH: 5.04 in (128 mm)
Tolerances are +/- 0.04 in. (+/- 1mm)
and +/- 0.08 in. (+/- 2mm) for height
dimensions. All data subject to
change without notice.
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com
www.upgi.com
Nominal Voltage
Nominal Capacity
20-hr. (1.30A)
10-hr. (2.42A)
5-hr. (4.42A)
1-hr. (15.60A)
Approximate Weight
Internal Resistance (approx.)
Shelf Life (% of normal capacity at 68º F (20º C)
3 Months 6 Months 12 Months
12 volts
26.0 Ah
7.8 A or smaller
14.6 - 14.8 V
77º F (25º C)
24.2 Ah
22.1 Ah
15.6 Ah
18.1 lbs (8.2 kgs)
14m
91% 83% 64%
102% 100% 85%
Charge Method
65%
(Constant Voltage)
Cycle Use
Float Use
Initial Current
Control Voltage
13.6 - 13.8 V
Control Voltage
(Repeating Use)
Specification
Physical Dimensions: in (mm)
Terminals
L1713-1
Sealed Lead-Acid Battery
UPG No. 45501
Maintenance-Free
UB12260FR
AGM Operational Temperature
AGM Storage Temperature
(0 C to 40 C)32 F to 104 F
5 F to 113 F
5 F to 104 F
(-15 C to 45 C)
Charge
Discharge
(-15 C to 40 C)
FR=Flame Retardant, ABS, UL 94V-0
Characteristics
6.57 (167)
5.04 (128)
6.89 (175)
Discharge Characteristics
(Minute) (Hour)
Discharge time
Cell voltage (V/Cell)
Discharge Time vs. Discharge Current
Discharge Current = CA X Nominal Capacity
(Minute)
(Hour)
Duration of Discharge
Copyright 2017 Universal Power Group Inc. All rights reserved.
Due to continuous improvements to our products, product may vary slightly from depiction.
All specifications are subject to change without notice.
Temperature Dependency of Capacity
104 F (40 C) 77 F (25 C)
(20 hour rate)
32 F (0 C) 5 F (-15 C)

Summary of content (2 pages)