UPG Data Sheet
Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation
in any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certied. U.L. recognized under le number
MH 20567.
Sealed Lead-Acid Battery
L: 6.57 in (167 mm)
W: 6.89 in (175 mm)
H: 5.04 in (128 mm)
TH: 5.04 in (128 mm)
Tolerances are +/- 0.04 in. (+/- 1mm)
and +/- 0.08 in. (+/- 2mm) for height
dimensions. All data subject to
change without notice.
Nominal Voltage
Nominal Capacity
20-hr. (1.30A)
10-hr. (2.42A)
5-hr. (4.42A)
1-hr. (15.6A)
Approximate Weight
Internal Resistance (approx.)
Shelf Life (% of normal capacity at 68º F (20º C)
3 Months 6 Months 12 Months
12 volts
26.0 Ah
7.8 A or smaller
14.6 - 14.8 V
77º F (25º C)
24.2 Ah
22.1 Ah
15.6 Ah
17.0 lbs (7.7 kgs)
14m
91% 83% 64%
Charge Method (Constant Voltage)
Cycle Use
Float Use
Initial Current
Control Voltage
13.6 - 13.8 V
Control Voltage
(Repeating Use)
Specification
Physical Dimensions: in (mm)
Terminals (T3)
UPG No. D5747
Maintenance-Free
UB12260
6.57 (167)
5.04 (128)
6.89 (175)
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com
www.upgi.com
All specifications subject to change without notice.
J2030-1
Temperature Dependency of Capacity
104 F (40 C) 77 F (25 C)
(20 hour rate)
102% 100% 85%
32 F (0 C) 5 F (-15 C)
65%
AGM Operational Temperature
AGM Storage Temperature
(0 C to 40 C)32 F to 104 F
5 F to 113 F
5 F to 104 F
(-15 C to 45 C)
Charge
Discharge
(-15 C to 40 C)
Due to continuous improvements to our products, product may vary slightly from depiction.
Copyright 2020 Universal Power Group, Inc. All rights reserved.
C
Discharge Characteristics
(Minute) (Hour)
Discharge time
Cell voltage (V/Cell)
Discharge Time vs. Discharge Current
Discharge Current = CA X Nominal Capacity
(Minute)
(Hour)
Duration of Discharge