SERIES 4000X Div.2 HAZARDOUS LOCATION STROBES
by Tomar Electronics 
Tomar Electronics introduces the Model 4000X family of Hazard-
ous Location Div. 2 Strobe Lights engineered to perform in the 
harshest environments. Constructed of 30% glass-lled thermo- 
set polyester, it is particulary well suited for installations in 
corrosive, wet NEMA 4X harsh environments, and hazardous 
locations. The high strength FRP material is resistant to the  
corrosive effects of most chemicals, hydrocarbons and solvents. 
Typical applications include manufacturing plants, chemical and 
petrochemical processing facilities, sewage treatment plants, off- 
shore and dockside installations, agricultural, commercial, 
industrial, mining and marine facilities. 
Totally non-metallic, these warning lights are fully potted in 
urethane material with no exposure to high voltage possible. 
NEMA 4X rated in any mounting configuration - base up, down or 
side positions.
 Flange Mount     Pendant Mount
    Wall Mount           
   With Optional Guard       With Optional Guard     With Optional Guard
 SPECIFICATIONS
Model No.  Description    Voltage
4024X    Xenon Strobe Body Only  12-80 VDC
4120X    Xenon Strobe Body Only  120 VAC
4240X    Xenon Strobe Body Only  240 VAC
Available Mounts & Guard Options
NVP    Pendant Mount
NVF    Flange/Ceiling Mount
NVW    Wall Mount
NVG    Dome Guard
Unique mounts allow for Pendant, Flange or Wall mount installa-
tions. Buy just the mounting style you need. Optional dome 
guard is also available.
• Class I, div. 2 groups A, B, C & D 
• Class 1, Zone 2, groups IIC, IIB, IIA
• Class II Div. 2 groups F & G, Class III 
• CSA Enclosure Type 4X, IP66
• NEMA 4X, Marine Rated
• 10 year warranty on Power Supply 
• 10,000 hour strobe tube
• Sealed construction
• 6 Lens Colors: Amber, Blue, Clear, Green, Purple & Red.
• 5001 Xenon Strobe Tube, 80 Flashes per Minute
• Temperature Range: -40C to +85C, Temp Code: T12
• Voltage/Amps: 400mA @ 12 VDC, 200mA @ 24 VDC,
 040mA @ 120 VAC, 020mA @ 240 VAC
 to the following standards
 ORDERING INFORMATION 
 12.6"         11.19"       11.35"   
        4.38"       4.38"        4.38" 
• UL 1598 Standard for luminaires
• UL 1598A Marine luminaires
• UL 844 Standard for lighting xtures for hazardous locations
• UL 1638 Standard for visual signalling applications
• CSA C22.2 no. 137-M1981 electric luminaires for use in  
hazardous locations
• Enclosed and gasketed, NEMA 3, 4X, IP66
144534_Body r7.indd 11 11/8/11 1:53 PM