Operating instructions
8 
o  If the fog is wet this is usually caused by turning up the volume too high. Only operate 
at 100% (below blast on the remote control) or below 75% on the DMX fog. 
o  If the fog rises this is usually caused by turning up the volume too high, or not enough 
refrigeration (see section 3.7). Only operate at 100% (below blast on the remote control) 
or below 75% on the DMX fog.  For short periods you can blast higher amounts of fog, 
but continuous use will cause residue accumulation (see section 4.3) and raise the 
temperature in the chiller causing rising fog. A 30-minute shutdown may be necessary to 
cool the compressor. Shut off the refrigeration switch (left side) for 30 minutes and wait. 
o  If the fogger or chiller circuit breaker blows you most likely have one of the following 
three fault conditions: 
1.  Low Line Voltage: occasionally the power company will be providing a voltage at 
the lower end of the acceptable range, but most likely, this fault is caused by using 
extension cords that are too long and of inadequate wire gauge. The 120V Polar 
Controller
TM
 requires a 20 amp circuit, so the extension cord should be at least 12 
awg (14 awg is too small). The 230V Polar Controller
TM
 requires a 10 amp circuit, so 
the extension cord should be at least 14 awg (16 awg is too small). 
2.  Running too long in continuous operation:  refer to section 3.7 to learn about the 
Polar Controller’s
TM
 duty cycle limitations. The Rest Period is important to avoid 
overheating the compressor in the chiller. You may pop the breaker on the 
compressor or activate the over-temp breaker on the compressor motor by running 
the unit too long. In either case the unit needs to be shut down for about 30 minutes 
to cool off. Then you can try resetting the chiller circuit breaker. The over-temp 
breaker auto-resets. 
3.  Internal short: If you are sure the voltage is adequate (90% of nominal) and you 
have let the unit cool off, then resetting the breaker should get it running again.  If the 
breaker immediately pops again, then you probably have an internal short, which will 
require factory service. See the section at the end of this booklet on service returns.  
5.10 Notes on DMX Operation 
1.  Polar Controller
TM
 and DMX 
CITC’s Polar Controller
TM
 Fog Unit has one DMX channel with 5-pin XLR to control on/off 
and volume output of fog (there is no timer on this DMX). 
The refrigeration unit has DMX. You may plug in the 5 pin XLR connector to the DMX 
function and set the address for the correct address. This will turn on/off the cooling 
portion (chiller) of the low-ground fogger when DMX control is above 50%. This unit uses 
5-pin XLR connectors. 










