Use and Care Manual

Page 12
GAS
BLUE LED
AUDIBLE & VISUAL SIGNALS
POWER
GREEN LEDHORN
OPERATIONAL SUMMARY
CONDITION / RECOMMENDATION
Silent
Off
On and Blinks
Off approx
every 20
seconds
Off Condition: AC power is present. DC power is present.
Recommendation: None
CO
RED LED
Silent
(alarmed
previously)
On and Blinks
Off approx
every 20
seconds
Off and Blinks
On approx.
every 5
seconds until
reset
Condition: Previous alarm condition at unidentified source.
Recommendation: QUICK FIND
®
Alarm Origination - In an interconnected
system, it is difficult to determine which alarm initiated the alarms to sound.
The QUICK FIND
®
feature will allow you to immediately locate the originating
alarm (once the alarms have stopped sounding). To initiate QUICK FIND
®
,
press the Test/Silence button on any alarm. After releasing the button, the
originating alarm will continue to sound for approx 60 seconds. In a non-
interconnected installation, it is necessary to test each alarm to determine
the originating alarm. Reset the originating alarm.
Silent
OffOff and Blinks
On approx
every 40
seconds
Off Condition: Alarm is powered by battery backup. AC Power is not present.
Recommendation: Check the breaker or fuse box for power. If the breaker
or fuse box looks normal, call a licensed electrician for assistance.
4 Beeps,
5 second pause,
1 beep
Blinks On in
sync with
the 1 beep
Turns off
when the
3 beeps start
Blinks On in sync
with the cycle of
4 beeps and
turns off
Condition: The test/silence button has been pressed. The test sequence
lasts for approx. 7 seconds.
Recommendation: None
Off*See below Off Condition: One or more units are not responding to interconnected alarm.
Recommendation: Turn off AC power at the circuit breaker or fuse box
and disconnect the alarm from the mounting bracket and make sure the
connector plug is securely attached on units that did not alarm. If still no
alarm, have a licensed electrician check to see if yellow wire is connected
properly.
Horn does not
sound when
other alarms
are active
or when
interconnected
alarm’s
test/reset
button is
pressed
4 Beeps,
5 second pause,
repeat
Off Blinks On in
sync with
4 beeps
Condition: Originating CO Alarm.
Recommendation: If hazard is identified, take all precautions if an alarm
sounds by calling an Emergency Service and getting out of the home.
4 Beeps,
5 second pause,
repeat
OffTurns off
when the
4 beeps start
Off
Condition: Non-originating CO Alarm.
Recommendation: An interconnected CO alarm has sensed CO, causing
all interconnected units to sound. If hazard is identified, take all precautions
if an alarm sounds by calling an Emergency Service and getting out of the
home.
Turns off
when the
4 beeps start
1 Beep,
2 second pause,
repeat
OffBlinks On
in sync
with the
1 beep
Condition: Originating GAS Alarm.
Recommendation: If hazard is identified, take all precautions if an alarm
sounds by calling an Emergency Service and getting out of the home.
1 Beep,
2 second pause,
repeat
OffTurns off
when the
1 beeps starts
Off
Condition: Non-originating GAS Alarm.
Recommendation: An interconnected GAS alarm has sensed GAS, causing
all interconnected units to sound. If hazard is identified, take all precautions
if an alarm sounds by calling an Emergency Service and getting out of the
home.
Turns off
when the
1 beeps starts
Off or Blinks
On in
sync with
the 1 beep
Condition: Nuisance Alarm.
Recommendation: If there is no hazard present, verify the alarm is mounted
in the correct location (see User’s Manual). Reset alarm as instructed below.
Horn sounds
when no
hazard is
present
Off or Blinks
On in sync
with 4 beeps
Turns off
when the
4 beeps start
4 Beeps,
5 second pause,
repeat
Blinks
On in sync
with 4 beeps
OffOn and Blinks
Off approx.
every 20
seconds
Condition: CO alarm when cause of alarm is known and poses no threat.
Recommendation: The CO alarm Silence Feature can be activated by pressing
and releasing the Test/CO Silence button on the initiating alarm while in alarm
condition. The alarm will remain silent for approx. 5 minutes (with the red LED
blinking on approx. every 10 seconds), depending on the level of CO detected.
If CO levels drop below alarm levels, the alarm will remain silent and return to
normal operation. If CO levels remain constant or increase, this indicates a
potentially dangerous situation and the horn will sound again. Ventilate area.
Off and
Blinks On
approx.
every 5
seconds
until reset