User's Manual

OWNERS INSTRUCTIONS
The USI-2413 has been assembled for the purpose of meeting the American
Disabilities Act requirements for visual signaling devices for the hearing impaired.
This kit contains (1) Model USI-1213 AC Smoke Alarm, (1) Model USI-960 Relay
Module and (1) Model USI-2177 177 Candela Strobe light.
INSTALLATION
The following wiring diagram can be used as a reference when installing this kit
and wiring the three units together.
IMPORTANT
Prior to installation, you must thoroughly read and understand each individual
component manual.
288-3272-00
INSTALLATION
Installation of this unit must conform to the electrical codes in
your area; Article 760 of the National Electrical Code, NFPA 72,
101; SBC (SBCCI); UBC (ICBO); NBC (BOCA): OTFDC (CABO),
and any other local or building codes that may apply. Wiring and
installation must be performed by a licensed electrician. Failure
to follow these guidelines may result in injury or property damage.
This unit must be powered by a 24-hour, 120V AC 60Hz circuit. Be
sure the circuit cannot be turned off by a switch, dimmer or ground
fault circuit interrupter. Failure to connect this unit to a 24-hour
circuit may prevent it from providing constant protection.
Smoke & Fire Alarm
Signaling Device Kit for
Hearing Impaired
MODEL USI-2413
©2000 UNIVERSAL SECURITY INSTRUMENTS, INC.
Printed in China
11407 Cronhill Drive, Suite A
Owings Mills, Maryland 21117 USA
Visit Us on the Web! www.SmokeAlarms.com

Summary of content (1 pages)