5.10.3. ALARM TYPES
Standard alarm for a 58 kHz tag. Click on the icon to enable or disable sound alarm.
Relay:
When an alarm occurs, the alarm
closes a relay and triggers anything
connected to it.
RELAY SPECIFICATIONS: 240V &
250mA.
Normal Open(NO) & Normal
Close(NC) contacts
Light Options:
Select the number of flashes. This feature is available for each antenna.
Select 'Change all at once' to apply changes in all antennas
This alarm occurs when system finds an inhibitor of 58 kHz
Check ON/OFF to enable or disable alarm detection. (Disable by default)
Enable / disable alarm sound.
Select threshold level when activating this alarm (>7 recommended).
This alarm occurs when a 58kHz label/tag is located near the antennas
Check ON/OFF to enable or disable alarm detection. (Disable by default)
Enable / disable alarm sound.
Synchro Signal: It is used to synchronize transmission blocks with zero crossing power line.
The signal comes out from the Power Supply and goes to the Transceiver Board Supply.
Enabled by default. When Power Synchro Signal fails, system would not run properly and alarm event
occurs.
This alarm occurs on entrance people detection
Disable by default. Click on the icon to enable or disable In-counting sound
This alarm occurs on exit people detection
Disable by default. Click on the icon to enable or disable Out-counting sound