3. QUICK TUNING
3.1. QUICK INSTALLATION
3.1.1. PREVIOUS
Always connect the system to clean power lines (No other electrical devices connected)
In order to avoid damaging the electronics, do not place any TURNED OFF antenna near a TURNED ON
Transceiver antenna. Please keep the minimum distance, not less than 50cm
Do not fix the system to the floor before testing its performance FIRST!
Do not place Receiver and Power line (220Vac/110Vac) cables along the same route.
Please Read this manual BEFORE installing systems!
3.1.2. SYSTEM INSTALLATION
Check cabling / connection needs according to the kind of installation. (See Section 4. CONFIGURATION).
Check all the material is ready.
Place the system in the installation area. (DO NOT fix the system to the floor).
Turn the system ON, and connect to the system (Follow Section 5. SOFTWARE)
Check Electrical Noise, Synchro, TX Status, etc.… check everything is normal.
Stabilize external electrical noise to the minimum.
Check Section 1.3. TABLE: SYSTEM / DETECTION / NOISE to define the maximum detection distance.
If any modifications, save parameters.
Disconnect your laptop and observe the system during some time making several detection tests (buzzer
can be disabled to not cause disturbance).
If OK, fix the system to the floor , if not OK, see Section 3.2. TROUBLESHOOTING
You are done!
3.2. TROUBLESHOOTING
3.2.1. NO DETECTION
Try with other tag
Rise Gain (Up to 2-3 LEDS)
Lower Threshold
See Section 3.4. NOISE PROBLEM
See Section 3.3. SYNCHRONIZATION PROBLEM
See Section 3.5. DEAD TRANSMITTER
See Section 3.6. DEAD RECEIVER
3.2.2. TOO MUCH DETECTION
Lower Gain
Rise Threshold
3.2.3. FALSE ALARM
Look for TAGS near the antennas
See Section 3.7. FALSE ALARM (OR UNKNOWN ALARM)
3.2.4. MAKES OTHER SYSTEMS FALSE ALARM
See Section 3.3. SYNCHRONIZATION PROBLEM