User's Manual

8
MONO82_USR_MAN_REV_A
This document was created to provide intended recipient documentation of requested device for technician purposes only. Any other usage of this document is an illegal and unlawful act. This document is a confidential and proprietary
document of Universal Surveillance Systems and consist of i nformation what can be protected by copyrights or the others intellectual property protection instruments of the others subjects. All other informa tion, what are not generally
known ones, is an intellectual property of Universal Surveillance Systems. This document including any and all attachments hereto is intended solely to be used by individual or entity to which it is addressed. If the reader of this
document is not the intended recipient, or an employee or agent responsible for delivering this document to its intended recipient, you are herewith notified that any dissemination, distribution, copying or retention of this document
or the informa tion contained her ein is strictly prohibited. If you have received this document in error, please notify us at service@un ivser aleas.c om i mmediately and permanentl y delete or/and destroy the original and any copy or
printout thereof.
Duration of alarm light - Number specifies the time (in seconds) of how long will be the
light alarm running after the
trigger.
Blink frequency
-
Sets
how fast will
be
the light alarm
blink.
Duration of alarm sound - Number specifies the time (in seconds) of how long will be the
sound alarm
running after the
trigger.
Beeper frequency
-
Changes the
speed interval of
beeps.
Type of beeps - You can choose between four types of beep intervals and assign them to
different types
of
alarms.
Test buttons
-
Serves for testing
of correct run of light and sound
alarms.
Watchdog - This counter may be very important as the device will automatically reboot
itself from time to time when it encounters an error. High number in short period of time
may indicate a problem with the
device. In that case contact
manufacturer.
6.4 MONO 8,2MHz
6.4.1 SYNCHRONIZATION
Synchro - Type of synchronization - Mains frequency - Follows the moment of zero
crossing from falling or rising edge based upon which transmit the signal. This option
allows you to make simple synchronization with other systems to avoid them from the
interference, that transmitting signal
is
delayed at the
desired time
(in microseconds).
Type of synchronization - Slave - System waits for synchronization pulses from "Master
unit". Set of Slave delay measurement of
synchronization
depending on cable length. In
case
of longer cable reduce
the
value.
Type of synchronization - Individual synchro - Manual settings of system transmitting
period. Use only in case of high interference from mains
power.