Users Manual

Wiring for magnetic door Wiring for automatic door Installation notes
1. Cables inside of the touch switch board shall keep far away from the center area of the board back.
2. When arrange the wires, if the 12V power supply cable of the host does not adopt the “Special power
strip” and is in long distance, resulting in large resistance, then abnormal phenomena may occur easily such
as insufficient voltage (≤11V), repeat restart, system crash and so on. Wiring connection of voltage
metering is shown as follow.
3. The power adapter with the device is shown as follow, 1m in total length, with 40cm low voltage power
cable and 40cm high voltage power cable.
V
1m
40cm 40cm
Total length of the power adapter with device
Power cable (weak current) 12-16V, 2A Power cable (strong current) 220V
System installation schematic
drawing for magnetic door
Wiring schematic drawing for touching
switch of magnetic door
System installation schematic
drawing for automatic door
Wiring schematic drawing for mechanical
switch of magnetic door
Host
Power
GND
12V
Cable equivalent
resistance1
Cable equivalent
resistance
Voltage meter
Wiring schematic drawing for
sensor switch of automatic door
12V
Controller of auto-door (only used terminals will be listed)
DC+
DC-
NO
COM
Sensor
DC+
DC-
NO
COM
12V
GND
RJ45-1
232 TXD
232 RXD
GND
WD0
WD1
NC
NO
COM
Host
RJ45-2
RJ45-2
RJ45-3
Ethernet
Host
Auto-door controller
+ assembly units
Sensor (inside)
DC12V
Wired or
Wi-Fi
~220V
Door exit
(inside)
Magnetic lock
Power
(access control)
Host
Wired or
Wi-Fi
~220V
PUSH
GND
12V
COM
NC
NO
12V
GND
NO
NC
COM
12V
12V
Power
(access control)
Door exit
Magnetic lock
12V
GND
RJ45-1
232 TXD
232 RXD
GND
WD0
WD1
NC
NO
COM
Host
RJ45-2
RJ45-2
RJ45-3
Ethernet
NO
NC
COM
Door exit
PUSH
GND
12V
COM
NC
NO
12V
GND
RJ45-1
232 TXD
232 RXD
GND
WD0
WD1
NC
NO
COM
12V
12V
Host
Power
(access control)
Magnetic lock
RJ45-2
RJ45-2
RJ45-3
Ethernet
7 / 8
Wiring connection
Opening signal PUSH
Public end GND
Extension of power cable (weak current) cannot exceed 2m, otherwise, it may cause insufficient
power supply for the host end, and abnormal phenomena like repeat restart, system crash may
occur. If the power is far away from the device, the power cable can be extended (strong current).
If use other power adapter, 9V 1A as an example, then insufficient voltage and too weak current
may cause repeat restart.
The cable cannot be too fine (such as network cable and fine line), it is suggested to connect
multi-strand cable in parallel or use copper core bold cable, to ensure voltage >11V.
Attention: If use network cable, the extension cable use 4-strand cable as positive pole and 4-strand cable as negative pole.
If not clear with how to extend, please contact the provider to change “Special power strip”.
Right
Wrong