Users Manual

Wiring for magnetic door Wiring for automatic door Installation notes
Wiring connection
7 / 8
1. When arrange the wires, if the 12V power supply cable of the host does not adopt the “Special power strip”
and is in long distance, resulting in large resistance, then abnormal phenomena may occur easily such as
insufficient voltage (≤11V), repeat restart, system crash and so on. Wiring connection of voltage metering is
shown as follow.
2. The power adapter with the device is shown as follow, 1m in total length, with 40cm low voltage power
cable and 40cm high voltage power cable.
1m
40cm 40cm
Total length of the power adapter with device
Power cable (weak current) 12-16V, 2A Power cable (strong current) 220V
Extension of power cable (weak current) cannot exceed 2m, otherwise, it may cause insufficient
power supply for the host end, and abnormal phenomena like repeat restart, system crash may
occur. If the power is far away from the device, the power cable can be extended (strong current).
If use other power adapter, 9V 1A as an example, then insufficient voltage and too weak current
may cause repeat restart.
The cable cannot be too fine (such as network cable and fine line), it is suggested to connect
multi-strand cable in parallel or use copper core bold cable, to ensure voltage >11V.
Attention: If use network cable, the extension cable use 4-strand cable as positive pole and 4-strand cable as negative pole.
If not clear with how to extend, please contact the provider to change “Special power strip”.
System installation schematic
drawing for magnetic door
Wiring schematic drawing for touching
switch of magnetic door
System installation schematic
drawing for automatic door
Wiring schematic drawing for mechanical
switch of magnetic door
Wiring schematic drawing for
sensor switch of automatic door
Auto-door controller
+ assembly units
Relay interface
Sensor (inside)
~220V
DC12V Ethernet
Host
Power
(access control)
Door exit
(inside)
Magnetic lock
Host
Relay interface
~220V
Ethernet
PUSH
GND
12V
COM
NC
NO
12V
GND
NO
NC
COM
12V
12V
Power
(access control)
Door exit
Magnetic lock
Ethernet
NO
COM
Host
12V
GND
Power
Relay
Opening signal PUSH
Public end GND
12V
Controller of auto-door (only used terminals will be listed)
Ethernet
DC+
DC-
NO
COM
Sensor
DC+
DC-
NO
COM
NO
COM
Host
12V
GND
Power
Relay
NO
NC
COM
Door exit
PUSH
GND
12V
COM
NC
NO
NO
COM
12V
12V
Host
Power
(access control)
Magnetic lock
12V
GND
Ethernet
Power
Relay
Power
GND
12V
Cable equivalent
resistance1
Cable equivalent
resistance2
Voltage meter
V
Host