Technical data

Index Protocols and Communication Data List
B-24
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Data
index
Data designation Channel
number
Setting range,
resolution
Motor
15 Melter status and alarms (Also refer to melter) 0 Bit field
[R] Bit 15 Value: 1 Motor circuit switch open
0 Motor circuit switch closed
25 General control data 0 Bit field
Bit 0 Reserved
Bit 1 Reserved
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Value: 1 Line started *
0 Line stopped *
* Applies to the features pressure build-up and flow control,
variation 1 (box:14, code:T) in the standard index protocol. In
the extended index protocol, via Melter control 1.
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Value: 1 Enable flow control mode
(for all motors)
0 Do not enable flow control mode
Bit
1015
Reserved
30 Motor mode 1 14 0 11 0
0: Speed control
1: Pressure control
[R] 10: Pressure build-up feature
[R] 11: Flow control
31 Switch motor to manual mode / key-to-line 1 14 0 / 1 0
0: Manual mode
1: Key-to-line
32 Speed setpoint, in manual mode 1 14 1.0 100.0 min
-1
5.0
33 Key-to-line
Line speed for max. pump speed (index 34) or for
max. pressure (index 80).
1 14 0.0 100.0 % 100.0
34 Key-to-line
Max. speed
1 14 1.0 100.0 min
-1
80.0
35 Key-to-line
Min. speed
1 14 0.0 100.0 min
-1
0.0
36
[R]
Actual speed 1 14 0.0 100.0 min
-1