Technical data
Index Protocols and Communication Data List
B-26
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Data
index
Data designation Channel
number
Setting range,
resolution
Motor
48 Reserved
49 Flow control
Pump speed when parent machine is stopped
1 − 14 1.0 − 100.0 min
-1
5.0
50-59 Reserved
Pressure
15 Melter status and alarms (Also refer to melter) 0 Bit field −
[R] Bit 14 Value: 1 Pressure buildup completed
0 Pressure build-up not completed
60 Pressure unit for all values 0 0 − 1 0
0: bar
1: psi
61
[R]
Actual pressure value (pressure sensor A) 1 − 16 0 − 100 bar
(0 − 1450 psi)
(0 − 10000 kPa)
−
62
[R]
Actual pressure value (pressure sensor B) 1 − 16 0 − 100 bar
(0 − 1450 psi)
(0 − 10000 kPa)
−
63
[R]
Actual pressure value (pressure sensor C) 1 − 16 0 − 100 bar
(0 − 1450 psi)
(0 − 10000 kPa)
−
64 Pressure setpoint (only pressure sensor A) 1 − 16 1 − 80 % of pres-
sure measuring
range end value
5
65 PID pressure control parameter Xp (gain P) 1 − 16 0.00 − 300.00 0.80
66 PID pressure control parameter Ti (integral action
time I)
1 − 16 10 − 65000 ms 600
67 PID pressure control parameter Kd
(differential portion D)
1 − 16 0.0 − 5.0 0.0
68 Reserved
69 Activate/deactivate pressure alarm monitoring 0 0 / 1 0
0: Deactivate
1: Activate