Technical data

Index Protocols and Communication Data List
B-26
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Data
index
Data designation Channel
number
Setting range,
resolution
Motor
48 Reserved
49 Flow control
Pump speed when parent machine is stopped
1 14 1.0 100.0 min
-1
5.0
50-59 Reserved
Pressure
15 Melter status and alarms (Also refer to melter) 0 Bit field
[R] Bit 14 Value: 1 Pressure buildup completed
0 Pressure build-up not completed
60 Pressure unit for all values 0 0 1 0
0: bar
1: psi
61
[R]
Actual pressure value (pressure sensor A) 1 16 0 100 bar
(0 1450 psi)
(0 10000 kPa)
62
[R]
Actual pressure value (pressure sensor B) 1 16 0 100 bar
(0 1450 psi)
(0 10000 kPa)
63
[R]
Actual pressure value (pressure sensor C) 1 16 0 100 bar
(0 1450 psi)
(0 10000 kPa)
64 Pressure setpoint (only pressure sensor A) 1 16 1 80 % of pres-
sure measuring
range end value
5
65 PID pressure control parameter Xp (gain P) 1 16 0.00 300.00 0.80
66 PID pressure control parameter Ti (integral action
time I)
1 16 10 65000 ms 600
67 PID pressure control parameter Kd
(differential portion D)
1 16 0.0 5.0 0.0
68 Reserved
69 Activate/deactivate pressure alarm monitoring 0 0 / 1 0
0: Deactivate