Technical data

Index Protocols and Communication Data List
B-30
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Data
index
Data designation Channel
number
Setting range,
resolution
Pressure
82 Motor control data 1 Bit field
Bit 0 Value: 1 Pressure build-up feature motor 1
enabled
0 Pressure build-up feature motor 1
not enabled
0
Bit 1 1 Pressure build-up feature motor 2
enabled
0 Pressure build-up feature motor 2
not enabled
0
Bit 2 1 Pressure build-up feature motor 3
enabled
0 Pressure build-up feature motor 3
not enabled
0
Bit 3 1 Pressure build-up feature motor 4
enabled
0 Pressure build-up feature motor 4
not enabled
0
Bit 4 1 Pressure build-up feature motor 5
enabled
0 Pressure build-up feature motor 5
not enabled
0
Bit 5 1 Pressure build-up feature motor 6
enabled
0 Pressure build-up feature motor 6
not enabled
0
Bit 6 1 Pressure build-up feature motor 7
enabled
0 Pressure build-up feature motor 7
not enabled
0
Bit 7 1 Pressure build-up feature motor 8
enabled
0 Pressure build-up feature motor 8
not enabled
0
Bit 8 1 Pressure build-up feature motor 9
enabled
0 Pressure build-up feature motor 9
not enabled
0
Bit 9 1 Pressure build-up feature motor 10
enabled
0 Pressure build-up feature motor 10
not enabled
0
Bit 10 1 Pressure build-up feature motor 11
enabled
0 Pressure build-up feature motor 11
not enabled
0