Technical data

1
32
MXHH002S033A0295
Installation
3-7
P/N 7135049A
E 2007 Nordson Corporation
VBC_Siemens
Connecting Hose
Also refer to the hose manual.
Connecting Electrically
1. First connect the hose (3) electrically to the unit.
Use hose receptacles XS10 to XS17 (Fig. 3-7, bottom row) for the plugs of
the hoses.
If there are more than eight hoses, use the hose receptacles XS 26(a) to
XS 35(a) on the electrical cabinet.
NOTE: For more than one hose: Every hose connection is allocated to a
corresponding receptacle. Do not mistakenly exchange!
Refer to wiring diagram for connecting arrangement.
Fig. 3-6
-XS10
-XS17
Ni 120
Pt 100
-XS17
-XS10
Melter Electrical cabinet
-XS 26.a
...
-XS 35.a
-XS 26
...
-XS 35
Fig. 3-7
Connecting
Second Open-jawed Wrench
Use a second open-jawed wrench when connecting and disconnecting the
hose. This prevents the unit’s hose connection from turning.
Fig. 3-8