SECTION 3  SETUP AND OPERATION 
ADJUSTING PEELER PLATE TO CONTAINER 
The peeler plate of the applicator needs to be adjusted square to the 
conveyor in both the flow direction as well as across the conveyor. To adjust 
in the flow direction, there is a knob under the applicator. Turning the knob 
clockwise will cause the applicator to tip forward. Turning the knob counter 
clockwise will cause the applicator to tip backwards. (See Fig.3 & 3a) 
To adjust across the conveyor, there is a knob in front of the applicator. 
Turning the knob clockwise will cause the applicator to tip inward. Turning the 
knob counter clockwise will cause the applicator to tip outward. 
 (See Fig.4 & 4a) 
Fig.3 
Knob 
Square Peeler Plate 
Fig.4 
Knob Applicator 
Fig.3a 
Conveyor 
Fig.4a 
Conveyor 