Operator`s manual
30
TROUBLESHOOTING CONTINUED 
PROBLEM WITH WRINKLE OR SKEWED LABEL 
The turning unit must be adjusted properly to the top of the conveyor. If the 
turning unit is tilted up, the container will want to rise up off the conveyor, which 
will wrinkle the label. Same problem, if the turning unit is tilted to far down it will 
wrinkle the label or cause the label to be skewed. (See Fig.8a) 
The backing plate must be adjusted properly. Too much pressure will squish the 
bottle and cause wrinkles. Not enough pressure and the label will not be wiped 
down properly. (See Fig.7) 
If the label is skewed one way or the other way (running up hill or down hill) and it 
is doing it consistently, use the skew adjustment to get the label on properly. 
(See Fig.24) 
The applicator should be square to the container. If the container has a taper to it 
then the applicator angle needs to match that taper. If the container is at 90° 
angle to the conveyor then the applicator peeler plate needs to be at a 90° angle. 
(See Fig.25) 
CONTAINERS NOT ALL GETTING LABELED 
If containers are going threw and all containers are not getting labeled, you need 
to check to make sure the product sensor is working correctly. (See Fig.11) Also, 
product spacing may be too close together. A label has to be completely 
dispensed before the product sensor can send another signal to get another label 
to dispense. (See Fig.12) 
LABEL NOT DISPENSING FROM APPLICATOR 
Make sure that the applicator switch on the control enclosure is “On”. Make sure 
that the motor switch on the applicator is “On” and running. If motor is “On” and 
not running, check to make sure that the motor is getting DC voltage. If motor is 
running and the labels are not dispensing, check that there is DC voltage to the 
clutch brake. If there is no DC voltage to the clutch brake, re-seat the circuit 
board behind the front panel of the applicator. If there is still no DC voltage to the 
clutch brake, check for AC voltage at the transformer behind the front panel of 
the applicator. If there is AC voltage at the transformer, the circuit board is bad. 
Make sure that the web lock link is disengaged. Check to see if setscrews are 
tight on the drive roll. 