7. ASSEMBLING INSTRUCTIONS
7.1  Clearances 
WARNING:  If this oven is not properly installed a fire may result. 
To reduce the risk of fire, follow this installation instructions. A major cause of oven related 
fire is failure to maintain required clearances (air spaces) to combustible materials. It is of 
utmost importance that this oven be installed only in accordance with these instructions. 
Please read this entire manual before you install the oven. Failure to follow instructions 
may result in property damage bodily injury or even death. Contact your local building or 
fire officials about restrictions and installation inspection in your area. 
CLEARANCES 
I) The Univex oven must have a minimum 1" clearance to combustibles from all 
size and 16" from combustibles from the top.
If  building  a  facade  that  will  contact  the  oven,  use  completely  non-combustible 
materials (when non-combustible building materials contact the body of the oven, 
the clearances to combustibles are transferred to those non combustibles). Please 
note that standard dry-wall (or sheet rock) is considered a combustible.
II) Any  facade  above  and/or  6  inches  to  either  side  of  the  oven  doorway,  must  be 
constructed of non combustible building materials
III) Install this oven only on non combustible floors. The non combustible floor surface 
should extend 40 inches out in front of the oven and extend 32 inches to either side 
of the oven doorway.
IV) Leave a clearance of at least 200cm
2
 under the oven
V) Leave a clearance for servicing and proper operation in case you are covering the 
iron stand
WARNING:  installation  and  servicing  of  this  product  could  expose  you  to 
glass wool/ceramic fibres and dust.
ALWAYS WEAR RESPIRATORY AND EYE PROTECTION WHEN INSTALLING OR 
SERVICING THIS APPLIANCE 