7.4  Hydraulic connection 
Mechanical  Maintenance  Technician:  the  qualified  technician  who  has  been 
trained to operate the equipment in normal working condition and to operate on 
mechanical  -  hydraulic  -  pneumatic  gears  in  order  to  make  adjustments, 
maintenance  interventions  or  repairs  according  to  the  instructions  outlined  in 
this manual. 
NOTE:  INSTALLATION  MUST  CONFORM  WITH  LOCAL  CODES,  OR  IN  THE 
ABSENCE  OF  LOCAL  CODES,  WITH  THE  NATIONAL  FUEL  GAS  CODE,  ANSI 
Z223.1/NFPA  54,  OR  THE  NATURAL  GAS  AND  PROPANE  INSTALLATION  CODE, 
CSA B149.1, AS APPLICABLE, INCLUDING: 
1. The  appliance  and  its  individual  shutoff  valve  must  be  disconnected  from  the  gas
supply piping system during any pressure testing of that system at test pressures in
excess of 1/2 psi (3.5 kPa).
2. The  appliance  must  be  isolated  from  the  gas  supply  piping  system  by  closing  its
individual manual shutoff valve during any pressure testing of the gas supply piping
system at test pressure equal to or less than 1/2 psi (3.5 kPa).
Connect the equipment to the gas distribution system with pipes and accessories to the 
oven's input valve (standard coupling ½”). 
Before turning on the burner: 
- Check that the gas pressure entering the electrovalve is not higher than
the rated value.
- Verify that the connecting tubes are tightly sealed.
- Install  a  gas  flow  stop  cock  near  the  oven  for  possible  emergency
operations and for a better regular management of the oven.
- Check  the  compatibility  of  the  available  fuel  with  the  type  of  nozzles
mounted on the burner.
The  type  of nozzles,  the  fuel  and the  maximum  operating  pressure 
are indicated in the plate on the oven. The flame minimum is factory 
adjusted. Univex accepts  no responsibility  for  any damage  caused  to 
the equipment or to third parties as a result of an incorrect installation. 