7.2  Positioning of the oven 
The equipment should be installed in a well-ventilated place, and possibly 
located under a smoke extraction panel in order to ensure the complete 
evacuation of exhaust gases, or directly connected to the flue pipe according 
to the construction type. The flue outlets for combustion smoke should be 
sized and engineered according to the applicable provisions. 
Make sure that the air inflow needed for combustion is guaranteed by a minimum surface 
of 5,4 ft
2
 (oven's lower area) and with an adequate air recirculation in the upper area 
through a minimum aeration zone of one squared meter. 
The oven should be positioned in such a way that it can be accessed during 
maintenance interventions. Once it has been positioned, please check the 
vent outlets. The combustion air amount for a correct combustion is 1907 ft
3
/h 
for 47 serie, while it's 2013 ft
3
/h for 59 serie. Minimum distances to be kept 
between the equipment and adjacent walls should not be less than 1 inch on 
each side. 
The figures below show the assembling operations to mount the oven's standing support 
and then to position the oven. 
The oven's standing support is 
made of 4 metal tubular elements 
that are respectively made of two 
sides with four verticals, a rear 
part and a front part. 
Arrange the standing support in 
the desired area and assemble 
the various parts as illustrated. 
Position the rear support on the sides, align the 4 
holes and connect the parts with nut and bolt 
including the washers on both sides. Repeat the 
operation for the front support (n. 2 holes) 
Lifting and Handling Equipment Operator: the operator who has been trained 
to use equipments for lifting and handling materials and machines. Handling 
operations should be carried out according to the instructions described in this 
manual and in compliance with the applicable laws in the country where the 
equipment is used. 
Rear 
support 
Vertical 