User Manual

Dell
PowerEdge R710 Technical Guide 25
Operating See Fresh Air for temperature information
Storage
-40° to 65°C (-40° to 149°F) with a maximum temperature gradation of 20°C per hour
Relative Humidity
Operating
See Fresh Air for humidity information
Storage
5% to 95% at a maximum wet bulb temperature of 33°C (91°F); atmosphere must be
condensing at all times
Maximum Vibration
Operating
0.26 Grms at 5350Hz for 5 minutes in operational orientations
Storage
1.54 Grms at 10250Hz for 10 minutes in all orientations
Maximum Shock
Operating Half sine shock in all operational orientations of 31 G 5% with a pulse duration of 2.6ms 10%
Storage
Half sine shock on all six sides of 71G 5% with a pulse duration of 2ms 10% Square wave shock
on all six sides of 27G with velocity change @ 235 in/sec or greater
Altitude
Operating
-16 to 3048m (-50 to 10,000ft) Note: For altitudes above 2950 feet, the maximum operating
temperature is de-rated 1°F/550ft
Storage
-16 to 10,600m (-50 to 35,000ft)
Airborne contaminant level
Class G1 or lower as defined by ISA-S71.04-1985 (G1 maximum corrosive contaminant levels measured at ≤ 50%
relative humidity)
Power Consumption Testing
Power Consumption Testing Table 6.
Feature
Energy Smart Power Supply
High-Output Power Supply
Dimensions
L-206.4 mm
1
x W-67.5 mm x H-76.5 mm
Status Indicators
1 x bi-color Light Emitting Diode
Integrated Fans
1 x 60 mm
Fixed Input Plug
IEC-C14
AC Cord Rating
15 Amps @ 120 VAC, 10 Amps @ 240 VAC
Input Voltage
90264 VAC
Auto-ranging
Yes
Line Frequency
47 63 Hertz
Maximum Inrush Current
55 Amps per supply for 10 ms or less
Hot-Swap Capability
Yes
Output Power
570 Watts
870 Watts
Maximum Heat Dissipation
1944.9 BTU per hour
2968.6 BTU per hour
Efficiency (20% - 100% Load)
86.990.5% @ 115 VAC
8892% @ 230 VAC
8588% @ 115 VAC
8790% @ 230 VAC
1
Does not include the power supply handle or ejection tab
Maximum Input Amps
Maximum input current (High Output870W):
12 A @ 90 VAC
6 A @ 180 VAC
Maximum input current (Energy Smart570W):