XAV-905P-240 Spec Sheet

We reserve the right to make technical improvements.
XAV905P-240
CAPACITY, DIMENSIONS, WEIGHT
Capacity
Pan Spacing / Pitch
Dimensions WxDxH
Net Weight
16 each - 18"x26" Full Size Sheet Pans
3-3/8 (85,5 mm)
34-1/8” x 39-5/16” x 73-5/16 (866 mm x 997 mm x 1862 mm)
403 lbs (183 kg)
POWER SUPPLY
VOLTAGE
PH
Hz
MAXIMUM AMP DRAW
REQUIRED BREAKER SIZE
kW
AWG
CORD & PLUG
240
3
60
119 A
150 A
38.4
AWG 1
NO SUPPLIED BY FACTORY
WATER REQUIREMENTS
Water inlet:
three (3) cold water inlets - drinking quality:
- one (1) treated water inlet: 3/4" NPT*, line pressure: 20 to 60 psi 2.0 to 6.2 bar * Can manifold off of one 3/4" line.
- two (2) untreated water inlet: 3/4" NPT*, line pressure: 20 to 60 psi 2.0 to 6.2 bar
Water drain:
1-3/16’’ (30 mm) connection with a 2’’ (25 mm) minimum air gap installed at least 1 feet (300 mm) far away from the oven
Water quality minimum
standards:
USING A WATER SUPPLY NOT MEETING UNOX’s MINIMUM WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. It is the responsibility of
the purchaser to ensure that incoming water supply is compliant with the specifications listed through adequate treatment measures.
Contaminant Inlet Water Requirements (untreated water): Free Chlorine: less than 0.1 ppm (mg/L); Hardness: less than 3 gpg (52 ppm);
Chloride: less than 30 ppm (mg/L); ph: 7.0 to 8.5; Alkalinity: less than 50 ppm (mg/L); Silica: less than 12 ppm (mg/L);
Total Dissolved Solids (tds): less than 60 ppm
INSTALLATION REQUIREMENTS
Oven must be installed level. Back-flow preventer integrated in the unit.
Installations must comply with all local electrical, plumbing and ventilation codes.
UNOX INC. 105 Terry Drive - Suite 119 Newtown, Pennsylvania 18940 Toll Free: 1-800-489-UNOX (8669) infousa@unox.com
www.unox.com
DIMENSIONS
A (B)
A: mm
B: (in)
DRAWING LEGEND
1
TERMINAL BOARD COVER BOX
6
TECHNICAL DATA PLATE
8
3/4" THREAD WATER INLET
10
Rotor.KLEAN™ CONNECTION
11
OUTLET
12
CHIMNEY
13
ACCESSORIES CONNECTION
23
COOLING WATER INLET
27
COOLING AIR OUTLET