Product Manual

Absorbant Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation i
n any position. Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certied. U.L. recognized under le number
MH 20567.
L: 2.61in (66mm)
W: 1.30in (33mm)
H: 3.82in (97mm)
TH: 4.03in (102mm)
Tolerances are +/- 0.04 in. (+/- 1mm)
and +/- 0.08 in. (+/- 2mm) for height
dimensions. All data subject to
change without notice.
488 S. Royal Lane Coppell, Texas 75019 P 469.892.1122 T 866.892.1122 F 469.892.1123 sales@upgi.com
www.upgi.com
Nominal Voltage
Nominal Capacity
20-hr. (0.16A)
10-hr. (0.30A)
5-hr. (0.54A)
1-hr. (1.92A)
Approximate Weight
Internal Resistance (approx.)
Shelf Life (% of normal capacity at 68º F (20º C))
3 Months 6 Months 12 Months
Temperature Dependancy of Capacity
104º F 77º F
6 volts
3.20 Ah
.96 A or smaller
7.3 - 7.4 V
77º F (25º C)
(20 hour rate)
2.98 Ah
2.72 Ah
1.92 Ah
1.28 lbs (0.58 kgs)
30 m
91% 83% 64%
102% 100% 85%
32º F 5º F
Charge Method
65%
(Constant Voltage)
Cycle Use
Float Use
Initial Current
Control Voltage
6.8 - 6.9 V
Control Voltage
(Repeating Use)
Specification
Physical Dimensions: in (mm)
Terminals
J2913-1
Sealed Lead-Acid Battery
UPG No. D5695
Maintenance-Free
UB632
6.35 4.45
2.61 (66)
1.30 (33)
3.82 (97)
4.03 (102)
All specifications are subject to change without notice.
AGM Operational Temperature
AGM Storage Temperature
(0 C to 40 C)32 F to 104 F
5 F to 113 F
5 F to 104 F
(-15 C to 45 C)
Charge
Discharge
(-15 C to 40 C)
Discharge Characteristics
(Minute) (Hour)
Discharge time
Cell voltage (V/Cell)
Discharge Time vs. Discharge Current
Discharge Current = CA X Nominal Capacity
(Minute)
(Hour)
Duration of Discharge
Due to continuous improvements to our products, product may vary slightly from depiction.
Copyright 2020 Universal Power Group, Inc. All rights reserved.