Specifications

PROBLEM SOLUTION
The heating system will
not activate.
Heating system seems to
cycle too often.
- Check the thermostat LCD display to see if there has been a power failure.
- If a lock appears on the LCD when you raise the temperature, the “HIGH-LIMIT FUNCTION”
is activated.
- Check heating device to see if it is disabled or if the circuit breaker is open.
- Check the wiring installation with a certified electrician.
Check and ensure that you have selected a Cycle Rate that matches your particular
heating system.
27
The temperature display is
incorrect.
- Ensure thermostat is not installed near a draft, in direct sunlight or near any devices
such are air conditioners or heaters.
The thermostat feels HOT
to the touch.
- In normal operation, the thermostat may range in temperature from 113° to 131°F
(45° to 55 °C) This is perfectly normal, because this thermostat is rated to operate
safely at these temperatures. However, it is recommended that the thermostat not be
installed near heat sensitive / flammable material such as exposed wood, wallpaper
or other fire hazards.
The heating system is
running constantly.
- Check the temperature is not set too high.
- Check the wiring installation with a certified electrician.