Overview of Primary Product

Radiant Ready 30E Installation Guide
31
Section 11
Customization Options
Hard-plumb Port
This is a radiant system which includes a boiler. Some
jurisdictions may require adding a fill to the system.
The fill can be attached to the hard-plumb port
located behind the return manifold (see Figure 11-1).
All fills (automatic or manual, as dictated by code)
must be purchased separately.
Manual Fill
This can be as simple as hooking the domestic
water to a ball valve and then the hard-plumb port.
Generally, manual fills include a pressure-reducing
valve and may include a check valve or backflow
preventer (check local code requirements).
Automatic Fill
This connects to the domestic water and the hard-
plumb port. Generally, auto fills include a pressure-
reducing valve and may include a check valve or
backflow preventer (check local code requirements).
Zoning/Control Options
When zoning with the Radiant Ready 30E, there are
multiple options available, including:
• Using alternative thermostats
Using a Zone Control Module to support up to
12 zones (with customization, Radiant Ready 30E
supports a maximum of 12 loops)
Using the Climate Co˘ntrol™ Zoning System
to support up to 12 zones through a wireless
connection
• Using the Climate Co˘ntrol Multifunction Controller
Using the Climate Co˘ntrol Network System to
integrate the Radiant Ready 30E with other
heating and cooling appliances (capable of
supporting up to 99 zones)
Alternative Thermostats
Some applications require slab sensing or thermostats
that can read heating and cooling temperatures.
Uponor offers a comprehensive array of thermostats
including the following.
• Uponor Heat and Cool Thermostat (A3030102)
Uponor SetPoint 501, Single-stage Setpoint
Controller (A3040501)
Uponor SetPoint 501s, Single-stage Setpoint
Controller with floor sensor (A3041501)
Uponor SetPoint 511s, Single-stage Programmable
Controller with floor sensor (A3041511)
Uponor SetPoint 512, Two-stage Programmable
Controller (A3040512)
• Climate Co˘ntrol Zoning System Thermostats
(A3600075, A3600275 and A3600054)
Note: Only use Zoning System thermostats with
the Climate Co˘ntrol Zoning System.
Important! The 50VA transformer inside
the boiler may be used to power the Uponor
Heat-only Thermostat (included with the
unit). However, the alternative thermostats
listed above or advanced configurations
with more than one device must use an
external transformer.
Zone Control Module
To create separate heat zones, connect Uponor
Thermal Actuators (A3010522) to the Engineered
Plastic (EP) Heating Manifold in the Radiant Ready
30E using EP Heating Manifold Actuator Adapters
(A2671300). Install an Uponor Zone Control Module
(ZCM) (A3030003 or A3030004) to control the boiler
and thermal actuators. ZCMs must be powered by
an external transformer. They may also be ganged
together to accommodate the desired number of
zones. A two- or three-wire thermostat may be
installed for each heat zone. Each thermostat must be
wired to the terminal block located directly above the
Figure 11-1: Hard-plumb Port