Overview of Primary Product

Radiant Ready 30E Installation Guide
9
Section 5
Piping Connections
Note: If your jurisdiction code requires a hard-
plumb port, see the Hard-plumb Port instructions
in Section 11: Customization Options.
Tubing Types
For radiant installations, the tubing must be one
of the following.
Crosslinked polyethylene (PEX) tubing with an
oxygen barrier that meets or exceeds DIN 4726
(such as Wirsbo hePEX™) in sizes
5
16",
3
8",
½",
5
8" or ¾"
Multi-layer Composite (MLC) tubing (PEX-AL-PEX)
in sizes ½" or
5
8"
Fitting Types
Connect the radiant tubing via one of the
following options.
• For PEX tubing connections, use either
º
ProPEX® expansion (for
3
8", ½",
5
8" and ¾") or
º
QS20 compression (for
5
16",
3
8", ½" and
5
8")
For MLC (PEX-AL-PEX) tubing connections,
use either
º
MLC press (for ½" and
5
8") or
º
MLC compression (for ½" and
5
8")
Refer to the image below for an example of the
four fitting options.
EP Heating Manifold,
4 loops (A2670401)
QS-style Compression Fitting Assemblies
(
5
16" A4020313,
3
4" A4020375,
1
2" A4020500,
5
8" A4020625)
MLC Tubing Compression Fitting Assemblies
(
1
2" D4120500,
5
8" D4120625)
ProPEX Fitting Assemblies
(
3
8" Q4020375,
1
2" Q4020500,
5
8" Q4020625,
3
4" Q4020750)
MLC Press Fitting Assemblies
(
1
2" D4020500,
5
8" D4020625)
Figure 5-1: Engineered Plastic (EP) Heating Manifold Fitting Types