Climate Control Zoning System II instruction sheet A3800165 A3801160 A3800167 A3801165
Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety measures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Technical constraints. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 .
Overview This instruction sheet is intended for experienced installers. Uponor strongly recommends reading the full installation and operation manual before installing the control system. Safety symbols The following symbols are used in this document to indicate special precautions when installing and operating any Uponor equipment. Warning! Ignoring warnings can cause injury or damage to components. Caution! Ignoring cautions can cause equipment malfunctions.
Installation System components Part no. Description A3800165 Wireless Dial Thermostat (T-165) A3800167 Wireless Digital Thermostat (T-167) A3801165 Wireless Base Unit, 6 zones (X-165) A3801160 Wireless Base Unit Expansion Module, 6 zones (M-160) System example 1 2 1 4 | uponorpro.
Wiring diagram Important! This instruction sheet serves as a reminder for experienced installers. Uponor strongly recommends using the full installation and operation manual for complete installation details. Pump relay Boiler/heat source > 15.
1 2 b 3 A3801165 A3801160 4 A3800167 A3800165 5 A3800167 c b 1 d a 3 24 V AC 2 a 6 ON DIP 7 1 2 3 4 A3801165 A3801160 A3800167 9 10 C VA 24 Hz 60 A3800167 6 | uponorpro.
System setup Important! Connect only one actuator for each channel. Channels 01 and 02 have double outputs (a and b) for two actuators. Caution! Ensure that each actuator is connected to the correct channel so that the thermostats are controlling the correct loops. 1. Attach the full assembly, or parts of it, to the wall either with a DIN rail or by using wall screws and plugs. If installing the controller inside a metal cabinet, locate the antenna outside the cabinet. 2.
1 2b 2a 2c 2a 3s 2b ec on ds 3 A3800165 4 2 5 3 A3800167 on ec 5s ds ds on ec 3s ds on ec 5s 8 | uponorpro.
Register thermostat and/or system device to a controller Enter registration mode 1. P ress and hold the OK button on the controller for about 3 seconds until the LED for channel 1 (or the first unregistered channel) flashes red. 2. To register a thermostat, select a thermostat channel. a. U se buttons < or > to move the pointer (LED flashes red) to a preferred channel. b. P ress the OK button to select the channel for registration. The LED for the selected channel starts flashing green. c.
Technical data General IP Maximum ambient RH (relative humidity) IP20 (IP: degree of inaccessibility to active parts of the product and degree of water) 85% at 68°F (20°C) Antenna Power supply Radio frequency Transmitter duty cycle Receiver class From controller 912 MHz <1% 2 Thermostats ERP Low-voltage tests EMC (electromagnetic compatibility requirements) tests ERM (electromagnetic compatibility and radio spectrum matters) tests Power supply Voltage Operating temperature Storage temperature Radio freq
Climate Control Zoning System II instruction sheet l 11
Uponor Inc. 5925 148th Street West Apple Valley, MN 55124 USA Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA T 800.321.4739 F 952.891.2008 T 888.994.7726 F 800.638.9517 CCZII_InstructionSheet_69569_1216, Copyright © 2016 Uponor. Printed in the United States. MKT10059_AB uponorpro.