Installation and Operation Manual

Connect external sensor to thermostat
1
2
3
SI0000046
Note
For accurate temperature: attach the outdoor sensor to
the north side of the building where it is unlikely to be
exposed to direct sunlight. Do not place it close to doors,
windows, or air outlets.
1. Remove the breakout plastic on the back of the thermostat.
2. Press the push buttons on the connection terminals.
3. While pressing the push buttons, insert the two wires from the
sensor cable (non polarized) into the connection terminal.
The external temperature sensor input can be used for either a floor,
outdoor or remote temperature sensor. Use the software on the
thermostat to select a control mode which corresponds to the use of
the sensor and thermostat.
Start the thermostat
SI0000105
Remove the plastic transportation strip from the battery to start the
thermostat.
The thermostat use a single CR2032 3V button cell lithium battery
which provides about 2 years of battery life, as long as it is positioned
within radio range of the room controller. Ensure that the battery is
correctly inserted in the thermostat.
The thermostat will perform a self test, for about 10 seconds, when
the battery have been inserted. The system will be blocked for input
during this period.
CD0000015
Current software version is displayed during power up.
Select thermostat control mode
SI0000113
Note
If no button on the thermostat is pressed for about
8 seconds, while in a submenu, the current values will be
saved and the software exits to the settings menu. About
about 60 seconds later, it exits to run mode.
If an external sensor is connected to the thermostat, a control mode
must be selected to accommodate the extra functionality of the
sensor.
See 04 Control mode, Page 93, for how to change the setting.