Installation manual

Uponor Control System
Technical data
General
IP: IP30 (IP: degree of non-accessibility to the active parts of the product and degree of non-accessibility of water)
Max ambient RH (relative humidity): 95% max at 20°C.
Thermostat
CE marking:
- Low Voltage Tests: EN 60730-1* and EN 60730-2-9***
- EMC (Electromagnetic compatibility requirements) Tests: EN 60730-1 and EN 301-489-3
- ERM (Electromagnetic compatibility and radio spectrum Matters) Tests: EN 300 220-3
Approval and certification:
- KNX: Konnex approval and certification
Power supply: 2x Alkaline AAA 1.5V
Voltage:2.2 V to 3.6 V
Operating temperature: 0°C to +45°C
Storage temperature: -10°C to +65°C
Radio Frequency: 868.3 MHz
Transmitter Duty Cycle: 1%
Interface
CE marking:
- Low Voltage Tests: EN 60730-1 and EN 60730-2-1
- EMC Tests: EN 60730-1
Power supply: 11VDC ±10% from Controller
Operating temperature: 0°C to +55°C
Storage temperature: -20°C to +70°C
Consumption: 1W max
Antenna
Power supply: 11VDC ±10% from Controller
Consumption: << 1W
Radio Frequency: 868.3 MHz
Transmitter Duty Cycle: 1%
Receiver Class: 2
Controller
CE marking:
- Low Voltage Tests: EN 60730-1* and EN 60730-2-1**
- EMC Tests: EN 60730-1 and EN 301-489-3
- ERM Tests: EN 300 220-3
Power supply: 230VAC +10/-15% 50Hz
Operating temperature: 0°C to +55°C
Storage temperature: -20°C to +70°C
Consumption: 70 W in full charge max
Pump relay output: 230VAC +10%/-15%, 250VAC μ 2A max
Heating/cooling input: Only Dry contact
Valve outputs: 24VDC ±10%, 436 mA max per output 1 and 2
24VDC ±10%, 218 mA max per output 3 to 12
Supply connection: EU - Plug 1 m cable, pre-mounted
Pump connection: wires 1.5mm² max
Heating / cooling connection: wires 1.5mm² max
* EN 60730-1 "Automatic electrical control to domestic use"
** EN 60730-2-1 "Particular Requirements for Electrical Controls for Electrical Household Appliances"
***EN 60730-2-9 "Specific rules for devices of thermo sensitive control"
Use of quick connectors:
Press, without turning, with a thin screwdriver on
the white button of the terminal to insert or
remove a wire
Insert a wire in the quick connector
Remove the screwdriver from the white button
Run the cable in the cable guides to block it in
secure
Screw clamp to secure the cable of antenna or/and
extension
1
2
3
4
5
Mark
Description
Terminal block for connection of antenna and
extensions
Interface RJ 9 connector
Push-button and LED from 01 to 12 for channel
registration
Test push-button and LED
Quick connectors for the actuators
Socket for the connection of the data stick
Power LED
230VAC 50Hz compartment - Pump
1
2
3
4
5
6
7
8
Usable in all Europe 0682
Declaration of conformity:
We hereby declare under our own
responsibility that products dealt with by
these instructions satisfy all essential
demands linked to the R&TTE 1999/5/CE
Directive dated March 1999.