The Uponor Climate Controller C-46 Supply water controller for radiant heating and cooling – easy to install – providing system efficiency 1
Product Climate Controller C-46 – convincing with advantages Easy installing & smooth running Supply water temperature control: Weather compensator: 80 Heating Cooling Heating & cooling Snow & ice melting Pump management: With internal fuse By zone Saves energy Pump exerercise Matches perfectly with Uponor Control System DEM C-56: C-56 thermostat can be shared Compensation of supply water temperature based on both indoor and outdoor temperatures H/C-state and ECOmode can be shared 2 70 0.8 60 1.
Product This is where safe and efficient heating and cooling starts Put the Climate Controller C-46 in charge – and the whole heating and cooling set-up will run smoothly The Uponor Climate Controller C-46 is a supply water controller for heating, cooling and snow and ice melting systems, applicable to Uponor radiant heating and cooling systems. Its main function is to regulate supply water temperature by controlling a mixing valve actuator in a very intelligent way.
Product Heart of the system – the C-46 Product Facts 1047844 UPONOR Climate Controller C-46 1047845 UPONOR Climate Controller C-46 extended In the basic version the weather compensator controls supply water in heating. It can be integrated in the C-56 room control via bus connection.
Product Modular design principle – right for every site Accessories and extensions for any need The Uponor C-46 is available with complemantary equipment – to make the most of any application. 1047846 UPONOR Humidity Sensor H-56 This wireless RH sensor with battery alarm comes with batteries and mounting kit. Up to six of these sensors can be connected to C-46 with antenna or via C-56. 1000513 UPONOR Antenna (white) 1046116 UPONOR Antenna (gray) Antenna wired to the C-46 to connect the H-56.
Combinations of Products C-46 works as stand-alone or team player System integration with C-56 Radio enhances capabilities The Uponor Climate Controller C-46 is a smart device by itself. It works as stand-alone or integrated in pump and shunt groups. Either way, its value is multiplied in combination with the Uponor Control System DEM.
Combinations of Products C-46 works as stand-alone or team player C-46 C-46 C-35 230 V AC 230 V AC H-56 24 V DC M M M 230 V AC Climate Controller C-46 as stand-alone – with Uponor wired indoor/ outdoor sensors as typical Supply Water Control combinable with all kinds of heatsources.
Application Radiant heating/cooling system examples: Underfloor heating in residential and office buildings powered by a boiler 2 x 0,5 mm2 max. 20 m C-56 C-56 T-75 T-75 I-76 C-56 T-75 2 x 0,5 mm2 max. 20 m 230 V AC C-46 2 x 0,4 mm2 max. 50 m 230 V 24 V M Underfloor heating and cooling in residential and office buildings powered by a boiler and a chiller 2 x 0,5 mm2 max. 20 m C-56 C-56 T-75 T-75 I-76 C-56 T-75 2 x 0,5 mm2 max. 20 m H-56 230 V AC T-54 C-46 alternative 2 x 0,4 mm2 max.
Application Radiant heating/cooling system examples: 2 x 0,5 mm2 max. 20 m C-56 C-56 T-75 T-75 H-56 Underfloor heating and cooling in residential and office buildings powered by a air to water or ground source heat pump H-56 I-76 C-56 T-75 2 x 0,5 mm2 max. 20 m H-56 T-54 230 V AC alternative 230 V 24 V C-46 2 x 0,4 mm2 max.
Application Radiant heating/cooling system examples: Ceiling heating and cooling in residential and office buildings using manifold distribution powered by a chiller and a boiler C-35 alternative T-75 T-54 H-56 230 V AC T-54 2 x 0,4 mm2 max. 50 m I-76 230 V 24 V C-46 alternative M 2 x 0,5 mm2 max. 20 m T-75 C-56 2 x 0,4 mm2 max. 50 m C-46 PuSh I-76 2 x 0,5 mm2 max. 20 m T-75 C-56 2 x 0,4 mm2 max.
Application Radiant heating/cooling system examples: I-76 Underfloor heating powered by a boiler and ceiling cooling powered by a chiller in residential and office buildings C-56 I-76 H-56 T-75 C-56 C-46 C-46 M T-54 M 24 V 230 V 24 V 230 V 230 V AC 230 V AC Underfloor heating and cooling and ceiling heating and cooling in residential and office buildings, powered by a boiler and a chiller 2 x 0,5 mm2 max. 20 m C-56 I-76 C-56 T-75 2 x 0,5 mm2 max.
Application Radiant heating/cooling system examples: Snow & Ice melting C-46 230 V AC 230 V 24 V M Your Application: Scribble how you could apply the C-46 on your site! 12
Operation modes Three basic modes of operation,various diversifications The table below shows which sensors are used in which operating mode.
Interfaces Wizard and Quick menu: secure an efficient setup In terms of setting up and handling the Climate Controller C-46 leaves the competition far behind. In contrast to just one main menu tree it comes with three elaborate interface menus: Wizard – great installation guide When the C-46 is started the very first time, it guides the installer to make the necessary primary settings of the system. Wizard helps you step-by-step through the installation process.
Special knowledge Efficient temperature setting: less energy, more comfort Adjusting the heat curve Economy and comfort modes The two parameters T-slope and T-adjustment are used to adjust the heat curve: The economy mode (ECO) is used to save energy. In heating mode, the economy mode reduces room temperatures with a given setback temperature. In cooling mode, the temperature is increased. Different economy profiles may be applied for the days of the week.
Special knowledge Cooling and dew point Emitter surface and humidity Design temperatures for cooling systems are specified according to the dew point. The dew point is defined by the room temperature and the relative humidity. The cooling capacity of the system is defined by the difference between the room temperature and mean water temperature.
Special knowledge Paremeters and settings Cooling – indoor compensated supply with dew point control In the operation mode cooling – indoor compensated supply with dew point control, will help you to prevent condensation problems if the actual condition in the room/zone is different from the design criteria. The functions require humidity sensor H-56 and can handle up to 6 sensors, placed in different room/zones.
Special knowledge Using the Indoor sensor influence When the C-46 is used without the Controller C-56 controlling single or multiple zones it works as a full flow system in cooling mode. The indoor influence is a supply temperature adjustment that is depending on the difference of the indoor temperature and the indoor set point. This means that the supply will be increased if the indoor temperature is to low and it will be decreased if the indoor temperature is too high.
Special knowledge Technical data Climate Controller C-46 Antenna CE marking Measures Width 106 mm, height 174 mm, total depth 84,5 mm (button depth 4 mm) IP IP30 (IP: degree of inaccessibility to active parts of the product and degree of water) Degree of protection IK04 Low voltage tests EN 60730-1* and EN 60730-2-1** EMC (electromagnetic compatibility) tests EN 60730-1 and EN 301-489-3 ERM tests (electromagnetic compatibility and radio spectrum matters) EN 300 220-3 Home and building electr
It makes sense to install the Uponor Climate Controller C-46. For safe and efficient heating & cooling, management of the system has to be intelligent and reactive. The C-46 provides continuous control and comfort. It is so easy to install, with the installation wizard as a perfect guide On the display you can read all about the set-up and what to do next – allowing fast and tailormade installation.