INSTALLATION AND USE MANUAL FAST FAST 03 1C FAST 03 2C FAST 02 2C ENGLISH MANUAL Installation and use manual models FAST 02 and FAST 03 120 v/230 v rev.
WARNING! All UR FOG fogging systems should only be used with UR FOG-branded fluids. It is strictly forbidden to use any fluid not previously authorized in writing by UR FOG srl.
02 INTRODUCTION OF THE PRODUCT Thank you for purchasing UR Fog product. The great patented technological innovations such as the liquid injection system, the disposable cylinders, the fact that they don’t need to be refilled, the ecological and economic system for the complete emptying of the cylinders, together with the heating system, all of them make the FAST fog generators the best fog devices with the best performance in the security market.
04 INSTALLATION TIPS FOR FOGGING SYSTEMS Please observe the following instructions for mounting UR Fog: 1. The machine must be installed avoiding to obstruct escape routes. 2. Verify the fog does not limit the visibility near: stairs, landings, moving objects that may cause: falls down, injuries or any damage to persons. 3. Do not look directly into the nozzle. Do not add any other substance into the cylinders. 4. The nozzle may reach high temperatures, touch it may cause burns. 5.
05 HOW TO ACTIVATE THE SYSTEM It is always recommended to affix the Fast 02 or Fast 03 on a wall even when is placed on a flat surface. Always verify that the bracket or the support surface are suitable for the weight of the machine. It is suggested not to install the machine behind walls in a limited close area without a specific ventilation to prevent a possible overheating. After removing the machine from the package, unscrew the two screws that stop the right side panel and remove it.
06 TECHNICAL SPECIFICATIONS * Industrial standard as from other manufacturers FAST 03 1C FAST 03 2C FAST 02 2C Weight without cylinders and battery 10 Kg 11 Kg 14,7 Kg Fog emission in a single shoot (max density) 3 200 m 3 3 400/1200 m3 200 m 3 Total emission capacity 800 m 1600 m 1500/4500 m3 Cyliders capacity 1 x 400 ml 2 x 400 ml 2 x 500 ml Work time without main power about 2 hours about 2 hours 2 hours 30 minutes Average Consumption 250 W 250 W 250 W Max power on heati
While connecting the machine to the mains power, it is raccomended to never disconnect existing ground cable. The fact of disconnecting or modifing existing cables voids the warranty and can cause troubles or accidents related to the temperature control. Connect ground cable from the system to the screw on the metal sheet.
OUTPUTS 6 EMPTY Output empty cylinder This output (NPN Open Collector) closes towards negative direction when at least one of the two cylinders is empty. 7 FAULT Fault output This output (NPN Open Collector) closes towards negative when there is a serious malfunction ( such as batteries expired, fault of power supply or temperature control fault), which compromises the functioning of the device and which requires a technical action. Fault signal due to supply absence has a delay of 20 minutes.
B - Esempio di collegamento di UR FOG con alimentatore esterno per uso Antirapina +12V + 12 V GND GND ARM 230V A.C. SHOOT GND Stabilized power supply IN 230V A.C. OUT 12V D.C. EMPTY ARM KEY FAULT TAMPER GND SHOT BUTTON In the diagram above Ur Fog is powered by an external power supply. When Fast 02 or 03 is used with an external power supply in case of power failure, the machine will not be able to shoot.
In case of an empty cylinder, the DL EMPTY led will switch on In case of a fault, DL FAULT will switch on By opening the cylinders doors, in addition to the DL TAMPER led switching on, the relay will switch Maximum applicable power on the outputs is 100mA D - Example of connection FAST 02-03 outputs with inputs of an antitheft normally opened with diods (1N4148) needed only with some equipments.
F - Example of connection FAST 02-03 outputs with relay board. 11 MEANING OF FRONT LEDS LED BLUE When on it means the machine is armed, hot and ready to shoot. When flashing means something is wrong. ARM FAULT EMPTY RESERVE LED RED When on when at least one cylinder is empty or it is in reserve (only FAST 03 1C) LED GREEN When on means Fast 02 o Fast 03 is hot and ready for the fog emission.
SHOOTING TIME SETTING AND FOG FLOW DIRECTION To set the shooting time, after opening the cylinders compartment door, at the top of the PCB, facing the board you must move the jumper P3 in “setting” position. SET TIME SHOOTS SET P3 RESET TAMPER Then, holding down the button S1 “SET”, 6 leds on the front will flash and each flash is equivalent to one second. If you press the button again, the shooting time is not added to the one previously set, but will restart from zero. N.B.
N.B. To correctly dimension the machines it is needed to verify that the saturation of the area occurs in faster time than the one supposed for the theft.
13 INSTALLATION, EXCHANGE AND CYLINDERS RESET RESET SET P3 RESET TAMPER ARM FAULT EMPTY RESERVE HEATING FIRST ENGIME SECOND ENGIME The cylinders for fog cannons Fast 02 and Fast 03 are guaranteed to work for 3 years from production date. The expiry date is printed on the top of them. After that date, cylinders should be changed even if they have not been used. It is recommend to return them to the same to the dealer, who will take care of disposal.
14 MAINTENANCE UR Fog generators do not require special care, however, it is recommended the support of qualified and authorized personnel for periodic annual monitoring, taking into account the following: 1- Verify the good working condition of alcaline batteries 2- It is advisable to replace the cylinders after 2 years from the installation 3- Verify the lock of the nozzle ferrule 4- Verify the entirety of the nozzle sphere 5- Check the air tightness of the circuit and the switch functioning 6- Interven
15 FAULTS AND POSSIBLE SOLUTIONS DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION The three front LEDs flash and the buzzer emits 1 beep / minute The +12 V input voltage is too low or too high Check the external power supply or the alarm unit The buzzer emits 2 beeps / minute Low battery but still can shoot Replace batteries - See paragraph 14 The buzzer emits 3 beeps / minute Low battery power can not shoot Replace batteries - See paragraph 14 Batteries absent Insert batteries False contact ba
16 RESET FROM FAULT CONDITION This process is useful to discriminate false interpretations of faults caused by electrical shocks or serious problems on power supply from thermal loop problems.
17 WARRANTY The warranty of UR Fog is two years and is handled directly from the dealer or authorized installer, so please contact your supplier to take advantage of warranty with the copy of the purchase document that contains the serial number of the machine. Not included in the warranty: moving parts and/or damages depending on the incorrect use unless it is found a manufacturing defect in origin. Liquid and cylinders are not covered by warranty.
DATE BATTERY EXCHANGE CYLINDER EXCHANGE YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n. NO YES NO n.
N.B. Ask for the PDF module writing to: support@urfog.com UR Fog S.r.l. Via Toscana 38 - 10099 San Mauro T.