User Manual

In case of an empty cylinder, the DL EMPTY led will switch on
In case of a fault, DL FAULT will switch on
By opening the cylinders doors, in addition to the DL TAMPER led switching on, the relay will switch
Maximum applicable power on the outputs is 100mA
D - Example of connection FAST 02-03 outputs with inputs of an antitheft normally opened with diods (1N4148)
needed only with some equipments.
The UR Fog outputs are normally
opened and connected with input zones
of the alarm control panel opened.
According to the diagram above:
when there is an empty cylinder the
entrance area L3 will detect an alarm;
if a failure occurs or the batteries run
down, L2 detects an alarm;
when you open the door of the
cylinders, L1 detects an alarm.
E - Examples of connections FAST 02-03 outputs with balanced inputs of an antitheft
In this diagram, putting the resistance value required by the alarm control panel used in the terminal UR Fog, with
not used outputs the central will see the correct resistance, while following the activation of an output, you will
have a pull-down causing the alarm of the corresponding zone.
+12V INPUT
GND INPUT
ARM INPUT
SHOOT INPUT
GND
EMPTY OUT
FAULT OUT
TAMPER OUT
GND OUT
CENTRAL ALARM
+
L1
L2
L3
+12V INPUT
GND INPUT
ARM INPUT
SHOOT INPUT
GND
EMPTY OUT
FAULT OUT
TAMPER OUT
GND OUT
10