User Manual

The cylinders for fog cannons Fast 02 and Fast 03 are guaranteed to work for 3
years from production date.
The expiry date is printed on the top of them.
After that date, cylinders should be changed even if they have not been used.
It is recommend to return them to the same to the dealer, who will take care of
disposal.
For Model Fast 03 1C, with one cylinder, the “reserve” signal occurs when the
machine has shot at least 50% of the expected duration of the cylinder, calculated in
seconds and not in quantity of fluid shot.
For this reason it is recommended to use only new cylinders, and reset only when
you actually inserts a new cylinder. After removing the screws from the door, take
away the cylinders and reset the warning light for empty cylinder. After this
operation, insert the new cylinder until you hear the “click” of the plastic support at
its top that goes into the slot, then close the door of the cylinder.
If the cylinder seemed “stuck” in the upper part DO NOT pull with force,
make a pressure with two fingers on top of the cylinder, such as to lower it.
Then try again to remove it. If the cylinder does not enter, check if the
cylinder plate of the motor remains lifted. If so see paragraph 14
In case of an empty cylinder to be replaced, it is recommended to replace it with the
second cylinder still full present in the machine, and a new cylinder will replace this
last one.
13
INSTALLATION, EXCHANGE AND CYLINDERS RESET
The cylinders supplied with the equipment are intended to be used only for a vertical (standard)
installation. In case of horizontal installation, please refer to your authorized reseller/distributor
to get the appropriate cylinders. I’s necessary to insert the cylinders with the black plastic plug.
SET
RESET TAMPER
P3
RESET
ARM FAULT
EMPTY
RESERVE
HEATING
FIRST ENGIME
SECOND ENGIME
14