User Manual

The three front LEDs flash and the
buzzer emits 1 beep / minute
Error reading thermocouples
Check the external power supply or the alarm unit
CAUTION
the shooting time has been reset
Reset cylinders - Paragraph 13
Set shooting time - Paragraph 12
Disconnect electrical power from the machine for a few
minutes. If this happens again contact technical
support. Not try to repair
The Jumper P3 is in the
“SET” position
The buzzer sounds continuously
and the LED flashes blue
The +12 V input voltage is too
low or too high
Pressure down and then pull
The plate is raised
The cylinder is stuck in the valvebody
Wiring error
Test the terminal that there is a minimum voltage
of between 11V - GND (5) + ARM (3),
when the anti-theft system is activated
Cannot arm,
BLUE LED doesn not become
on
When you press the reset
cylinder button can not hear
the sound of the buzzer, the
all front leds flash but the
red LED does not reset
The cylinder does not enter
The cylinder does not exit
The buzzer emits 2 beeps / minute
Replace batteries - See paragraph 14
Low battery but still can shoot
The buzzer emits 3 beeps / minute
Replace batteries - See paragraph 14
Low battery power can not shoot
The buzzer emits 10 consecutive
beeps every minute
Insert batteries
Batteries absent
Move the batteries, turn them
False contact battery case
Remove and reinsert the connector
Connector not correct inserted
In any case it is useful to use a tester to verify the presence of voltage on the battery case
Has not been made the reset of the cylinders
Reset as described in paragraph 13
The front red LED is on
The cylinders are empty – Change the cylinders
as described in paragraph 13
The heat exchanger has not yet reached the minimum
temperature of shooting, wait for stop flashing
(standard time of heating 60 min)
The front green LED flashes
The machine is armed
(BLUE LED ON)
but does not shoot
For security reasons and to avoid false fog emissions in
power, when the machine is armed, it becomes operative
only after 20”.
After this time, the emission is instantaneous
The machine does not shoot
immediately after arming
Verify that the alarm once activated has a tension on
connectors of at least 12V
Wiring error
Pressure down and then pull
See the setting mode of the shooting
time at paragraph 12
The jumper P3 stands in
the “RESET” position
Setting the shooting time, the
buzzer does not sound and the
LEDs do not flash
DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION
15
FAULTS AND POSSIBLE SOLUTIONS
16