While connecting the machine to the mains power, it is
raccomended to never disconnect existing ground cable.
The fact of disconnecting or modifing existing cables voids the
warranty and can cause troubles or accidents related to the
temperature control.
Connect ground cable from the system to the screw on the
metal sheet.
08
BATTERIES
- To use only high quality alkaline batteries
- To replace them within the expiry date
- to replace them every 12 month anyway
- When Fast 02 / Fast 03 report the signal of battery low (paragraph 14 and 16)
- Test the battery case during every maintenance (paragraph 16)
The batteries are intended to maintain the efficiency of the electronic card, allowing the fog emission even in absence of
power supply from the electricity grid, until the heating system has a sufficient temperature. The batteries also have the
purpose of activating the motors that lift up the plates holding the cylinders, even when the main power supply or 12V from
the alarm system is available. Without batteries, with dead batteries, rechargeable or poor quality ones, the motors do not lift
up the plates that push the cylinders.
For this reason it is important:
09
DESCRIPTION OF INPUT AND OUTPUT CONNECTIONS
After inserting the batteries, it is important to check that they are in good contact with the battery case to
guarantee the proper functioning. Description of how to make tests is in paragraph 16.
INPUTS
1 + 12V Power input
2 GND Power input - In these inputs is necessary to provide a stable supply, between
11V and 14V DC from the alarm control panel or from an external 12V power supply.
This power is necessary to the operation of the LED and for the logic of operation.
In the absence of voltage on this input, the logic part will continue to operate, but not
the heater. For about 2 hours and 30 minutes, or until the temperature of the heat
exchanger (heating system) allows, Fast 02 or Fast03 may produce fog.
The maximum current drawn from UR Fog on this input is 230 mA.
3 ARM Arming input - By connecting this input to positive, Fast 02 or 03 is armed, blue frontal led is switched on and
when the machine reaches proper temperature it means that it is ready for shooting. In case of alarm, opening ARM input,
the fog emission stops immediately, even if the time set wasn’t reached.
4 SHOOTS shooting input - By connecting this input to positive, Fast 02 or 03 is armed, blue frontal led is switched on
and when the machine reaches proper temperature it means that it is ready for shooting. In case of alarm, opening ARM
input, the fog emission stops immediately, even if the time set wasn’t reached.
5 GND - Negative reference connected to terminal 1
SET
RESET TAMPER
P3
1
2
3
4
5
6
7
8
9
+12V
GND
In ARM
In SHOOTS
GND
EMPTY
FAULT
TAMPER
GND
BATTERY CONNECTOR
7