User Manual

A Example of connection FAST 02-03 inputs with outputs of a central anti-theft standard
B Example of connection FAST 02-03 for anti-robbery use with external power supply
C Example of connection FAST 02-03 outputs to drive LEDs and / or relays
D Example of connection FAST 02-03 outputs with inputs of an antitheft normally opened with diods (1N4148)
needed only with some equipments.
E Example of connection FAST 02-03 outputs with balanced inputs of an antitheft
F Example of connection FAST 02-03 outputs with relay board
10
CONNECTION EXAMPLES
Remember, it is necessary to connect all three outputs to an alarm central or an electronic panel that can see
all those information in real time and take proper action.
In order to avoid accidental activation with subsequent fog emission, the inputs are in “negative security”, for
this reason the disconnection of a wire does not cause activation.
So it is necessary to check carefully the reliability of connections and protect the cables to the control panel to
avoid the risk of accidental damages.
OUTPUTS
6 EMPTY Output empty cylinder
This output (NPN Open Collector) closes towards negative direction when at least one of the two cylinders is empty.
7 FAULT Fault output
This output (NPN Open Collector) closes towards negative when there is a serious malfunction ( such as batteries
expired, fault of power supply or temperature control fault), which compromises the functioning of the device and
which requires a technical action. Fault signal due to supply absence has a delay of 20 minutes.
8 TAMPER Tamper output
This output (NPN Open Collector) closes towards negative direction when you open the door cylinders or when the
accelerometer detects a sudden movement (such as the detachment from the wall)
9 GND Negative reference
It’s recommended not to use the space close to the
valves/junction for the cables.
The diagrams and examples below are intended only for a “better
understanding” of the operation of the inputs / outputs. None of
the diagrams below represents the “single scheme to perform”
as, in respect of the reference standard EN50131-8, there are
precise indications and only using all inputs and outputs on the
PCB it is possible to abide by the standard.
A - Example of connection FAST 02-03 inputs with outputs of a central anti-theft standard
In the diagram above the control panel, as example, provides
to UR Fog power supply between 11 and 14V DC 250 mA
max. The ON/OFF output of this power plant is an Open
Collector NPN opened when the system is off and it is stably
closed to negative for all the time in which the system still lit.
The alarm output of the plant is normally open and becomes
positive during the alarm time
+ 12V
GND
ARM
SHOOT
GND
CENTRAL ALARM
OC NPN OUT ON/OFF
+ INTERNAL SIREN
+
+ 12V OUT