User Manual

For safety reasons and to avoid false fog emissions in power,
when Fast02 or Fast 03 is armed, it becomes operative only after 20”.
After this time, the fog emission is instantaneous.
In the diagram above Ur Fog is powered by an external power supply.
When Fast 02 or 03 is used with an external power supply in case of power failure, the machine will not be able to shoot.
For this reason, when the anti-robbery function must be guaranteed in the absence of power, it is needed to add a rechargeable
battery with a capacity of 1.2 Ah 12V in parallel to the output of power supply.
The arming key is important, as required by law, to allow you to disarm the device when not in use and during maintenance.
The shooting button, when the machine is armed, starts the fog emission immediately after pushing the button with the shooting
time already set in advance.
To stop the fog emission before the set time, turn the key to disarm the machine.
B - Esempio di collegamento di UR FOG con alimentatore esterno per uso Antirapina
+12V
GND
ARM
SHOOT
GND
EMPTY
FAULT
TAMPER
GND
+ 12 V
GND
ARM KEY
SHOT BUTTON
Stabilized power supply
IN 230V A.C.
OUT 12V D.C.
230V A.C.
C - Example of connections FAST 02-03 of outputs to drive LEDs and/or RELAY
In case of an empty cylinder, the DL EMPTY led will
switch on.
In case of a fault, the DL FAULT led will switch on.
By opening the cylinders door, in addition to the
DL TAMPER led switching on the relay will switch.
Max power applicable on the outputs is
100mA
9