Instructions / Assembly
Fasteners should be placed in the
grout lines of the TEXTURE PAN-
EL or in an inconspicuous place. All
screw heads should be counter sunk
about 1/8” into the stone.
See 4.2 for caulking screws section.
For exterior applications the panel must be fastened a
minimum of every 2 . It is important in high wind
regions and on the sun side of the building to add some
additional screws around the perimeter. See the chart for
the recommended number of screws required.
No. of Screws
3.3Amount Of Screws Required:
When applying the URESTONE panels, the use of screws is recommended as the
primary method of attaching panels to walls and columns. In some applications, a
combination of screws and adhesive is recommended.
3.0 SCREW RECOMMENDATIONS
3.1 Screw Recommendations
e URESTONE Panel
can be fastened over
wood substrates using
coarse thread exterior
deck screws, masonry
substrates require concrete
“TAPCON” type screws
(pre-drilling with ham-
mer drill will be required),
and steel substrates using
self tapping metal screws. e screws must
be exterior grade for outside applications
(Painted, Galvanization or Stainless) and
must penetrate the substrate a minimum of
3/4 ”. Typically 2 1/2”-3” will work for most
applications but depends on thickness of
the panel.Use No. 8 or No 10 size with Phil-
lips head type screw
Colored deck screws can be used for most
applications. Use a color that is closest to
the stone panel color. However, caulk will
be applied over the screw.
3.2 Placement Of Screws
Interior Exterior
2 x 4 ~6 ~10
4 x 8 ~10 ~18
Wainscot ~8 ~15
Wainscot
It is also recommended to glue the keys together
on exterior applications. (see Adhesive Recom-
mendation section)
2’ x 4’ Panels
recess screw
below surface
Apply
screw at
an angle
below
a large
stone
Apply screw in
mortar joint
4’ x 8’ Panels