Residential and Commercial HVACR Standard Motor Catalog HEATING VENTILATION AIR CONDITIONING REFRIGERATION AGRICULTURE
Rely on US ™ TRAINING TR R AINING TECHNOLOGY TECHN NOLOGY SUCCESS D EDICATION DEDICATION PERFORM MANCE MANCE PERFORMANCE You can rely on the U.S. MOTORS ® brand to offer Pool and Spa Motors that are highly respected products in the industry. Every day we strive to be a better partner with you and answer your needs through our responsive, knowledgeable and collaborative team. We understand the needs and goals of the industry and innovate products to meet those ever changing demands.
Customer Service Quick. Accurate. Responsive.
Quick Summary HVACR Motor Cross Reference Motor Description Model +LJK (I¿FLHQF\ Model Model Model Model AOS/Century Fasco Genteq Magnetek U.S.
Table of Contents INTRODUCTION Customer Service Centers Quick Summary HVACR Motor Cross Reference How To Use Motor Listings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i Catalog Numbering System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii Model Number Explanation (FHP) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Suitability of Integral Horsepower (IHP)* Motors on Variable Frequency Drives .
Table of Contents GENERAL PURPOSE SINGLE PHASE MOTORS General Purpose Single Phase Motors Overview . . . . . . . . . . . . . . . . . . . . . .85 General Purpose Single Phase Open Drip-Proof (ODP), Split Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 General Purpose Single Phase Totally Enclosed, Fan Cooled (TEFC) Split Phase . . . . . . . . . . . . . . . . . . .87 General Purpose Single Phase Open Drip-Proof (ODP), Resilient Base, Capacitor Start . . . . . . . . . . . . . .
How To Use Motor Listings Select the Application: Air Conditioner, Fan, Pump, etc. Select the Motor Type: Capacitor Start, Split Phase, Shaded Pole, Permanent Split Capacitor, Or Three Phase Select the Enclosure: Open Drip-Proof, Totally Enclosed, etc. Select the Mounting Type: Resilient Base, Rigid Base, Stud, etc. Select Other Parameters: Horsepower, Voltage, Speeds, Service Factors, Bearing type, etc. Permanent Split Capacitor Condenser Fan 5.
Catalog Numbering System (IHP) CORRO-DUTY® C 25 HP 25 (QHUJ\ (I¿FLHQW Three Phase E ( ) 1 2 3 4 1 PRODUCT FAMILY 8P A AB B BD BF BM BMU BR C CA CJ CO D DC DD DH DJ E EE ELT EZ FD FDU FF FP H HC HJ HO HS HT HVW HW J JD JT KT LD LT M NO NT PD PF PT PW S T TA TN U UI UJ UN UV VB VN WD WDP WDS WI WII X XA XC XJ XS Y YC YS 841 PLUS AUTOMOTIVE DUTY AUTO DUTY BRKLESS BRKMTR INVERTER DUTY BLOWER COOLED BELT DRIVE FAN BRAKE MOTOR-FAST BRAKE MOTOR UNIMOUNT® BRAKE MOTOR BRAKE MOTOR-FCR CORRO-DUTY® CORRO-DU
Model Number Explanation (FHP) K55HXRWS-8158 U.S. MOTORS® Type of Electrical Motor K 55 HX RWS - 8158 Diameter of Stator (e.g. 5.5") Thermal Protector Model Code beginning with A&S thru Z are catalog motors. All others are OEM specific )LUVW OHWWHU GHVFULEHV WKH W\SH RI PRWRU K55HXRWS-8158 ) 6KDGHG 3ROH . .$ 3HUPDQHQW 6SOLW &DSDFLWRU & &$ RU .6 &DSDFLWRU 6WDUW 3 3RO\ 3KDVH 5 RU 5.
Suitability of Integral Horsepower (IHP)* Motors on Variable Frequency Drives Applying motors that do not have INVERTER GRADE® insulation on Variable Frequency Drives (2, 4, 6 pole) Cable Distances Maximum Cable Distance VFD to Motor ®† Meet NEMA A MG-1, Section IV, Part 31.4.4.2. They can be used with adjustable frequency drives under the following parameters: On NEMA A®† frame motors, 10:1 speed rating on variable torque loads & 4:1 speed range on constant torque loads.
Motor / Inverter Compatibility Thermal Overloads and Single Phase Motors Multiple Motors on a Single VFD Motors with thermal overloads installed may not operate properly on a VFD. The current carrying thermal overload is designed for sine wave power. Operation on a VFD may cause nuisance tripping or potentially not protect the motor as would be expected on line power.
Limited Warranty Refer to usmotors.com website for the most up-to-date warranty information. All Nidec Motor Corporation products shall carry the limited warranty of 12 months from the date of installation, not to exceed 18 months from date of manufacture except those specifically listed below, or noted within individual product family pages within this catalog.
Heating & Air Conditioning For use in condensing units, furnaces, evaporative coolers, commercial package equipment and conditioned air systems. Horsepower: 1/10 – 2 HP Phase: Single and Three Phase RPM: 825, 1075, 1625 or 3450 RPM Voltage: 115, 208-230, 460 or 575 Volts, 60 Hz; some motors are rated 50/60 Hz (I¿FLHQF\ Standard and Premium HEATING & AIR CONDITIONING (HVACR) Enclosure: Open Drip-Proof (ODP) Totally Enclosed, Air Over (TEAO) Mounting: Extended Stud or Resilient Rings.
HVACR HVACR RESCUE RESCUE HVACR OEM RESCUE® PSC Direct Drive Fan 3.3" Diameter, Open Air Over APPLICATIONS: +LJK (I¿FLHQF\ 36& PRWRUV IRU UHIULJHUDWLRQ HYDSRUDWRU DQG JHQHUDO SXUSRVH 5HYHUVLEOH 5RWDWLRQ 36& 'HVLJQ ZLWK &DSDFLWRU ,QFOXGHG /HDGV )RXU [ 6WXG ([WHQVLRQV $W (DFK (QG %DOO %HDULQJV +DYH $OO $QJOH 7KUXVW 6\VWHP $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU DQG IHDWXUH GXDO SOXJ FRUG IRU ÀH[LELOLW\ CLOSE COUPLED PUMP COMMERCIAL DUTY PUMP RESIDENTIAL WATER SYSTEM PUM
HVACR HVACR RESCUE RESCUE RESCUE® ECM Walk-in Evaporator Motors HVACR OEM APPLICATIONS: +LJK (I¿FLHQW (& 5HIULJHUDWLRQ 0RWRU GHVLJQHG IRU :DON ,Q &RROHUV )UHH]HU $SSOLFDWLRQV FEATURES: RPM/Spds 1550-1625 1550-1625 1550-1625 Voltage 115-230 115-230 115-230 Catalog Number EC5404D EC5405D EC5406D 'XDO 9ROWDJH 1R &RQQHFWLRQ &KDQJH 5HTXLUHG %RG\ 6W\OH /RZ 3UR¿OH 6WDQGDUG 7KUHDG 0RXQWLQJ 6WXGV /\DOO 3OXJ 7KHUPDOO\ 3URWHFWHG 5REXVW %DOO %HDULng System Meets ATEX Directive 94/9/EC *Amps .60-.
HVACR HVACR RESCUE RESCUE HVACR OEM RESCUE® Motors Permanent Split Capacitor Condenser Fan 5.0" Diameter, Totally Enclosed, Air Over (TEAO) APPLICATIONS: Commercial and Residential Condensing Units. Can replace a range of horsepower application and a variety of mounting styles. XI (= ),7 7® mounting system to cover 4.3", 4.4" or 4.
HVACR HVACR RESCUE RESCUE RESCUE® Motors Permanent Split Capacitor Condenser Fan 5.6" Diameter, Totally Enclosed, Air Over (TEAO) Commercial and Residential Condensing Units. Can replace a range of horsepower application and a variety of mounting styles.
HVACR HVACR RESCUE RESCUE HVACR OEM RESCUE® Motors Permanent Split Capacitor Direct Drive Fan & Blower, 5.6" Diameter, Open, Air Over APPLICATIONS: Commercial and Residential Air Handlers and Furnaces. Can replace a range of horsepower applications and a variety of mounting styles. C HVACR FEATURES: XD ([WHQGHG 0RXQWLQJ 6WXGV 'HVLJQHG )RU 8VH :LWK 9 &DSDFLWRUV &ODVV % ,QVXODWLRQ /HDGV +LJK (I¿FLHQF\ 'HVLJQ ® ,QFOXGHV 6LGH 6KHOO +ROHV )RU RHEEM ®† Units &RQWLQXRXV 'XW\ $LU
HVACR HVACR RESCUE RESCUE RESCUE® Liberty™ Condenser Fan and Direct Drive Blower HVACR OEM APPLICATIONS: PSC motors for condensing unit and blower applications. Built in Princeton, Indiana. FEATURES: RESCUE Liberty Furnace and Air Handler Direct Drive Blower Multi-Horsepower Motors Horsepower: í +3 Enclosure: Totally Enclosed Air Over (TEAO) Speed: See Below Rated Voltages: í 9ROWV Ambient Rating: 70˚C (158˚F) Capacitor: 5.0 or 7.
HVACR HVACR RESCUE RESCUE HVACR OEM RESCUE ECOTECH® +LJK (I¿FLHQF\ Direct Drive Blower Motor APPLICATIONS: Drop-in replacement for PSC Direct Drive Commercial and Residential Air Handlers and Furnaces. (OHFWURQLFDOO\ &RQWUROOHG Brushless Permanent Magnet Motor & $PELHQW 5DWHG 5HYHUVLEOH 5RWDWLRQ )UDPH 'LDPHWHU 1R &DSDFLWRU 5HTXLUHG
HVACR HVACR RESCUE RESCUE RESCUE® SelectTM OEM Replacement ECM Blower Motor 6651RS 8QLYHUVDO KLJK HI¿FLHQW (&0 GHVLJQHG DV D GURS LQ UHSODFHPHQW IRU 2(0 FRQVWDQW WRUTXH PRWRUV HVACR Replaces X13 ®† and SeleTech® constant torque ECM motors Programmed Torque Values set to match OEM performance* Uses Equipment's existing connections, for ease of installation +LJK (I¿FLHQF\ 'HVLJQ 6mooth, Quiet Start-Up and speed changes Potted Electric Module for Superior Moisture Protection 6000V Surge Protec
HVACR HVACR RESCUE RESCUE HVACR OEM RESCUE PERFECTSPEED® ECM Ventilation Motor ZLWK 8VHU ,QWHUIDFH IRU 6SHHG &RQWURO +LJK (I¿FLHQF\ APPLICATIONS: Commercial Ventilation and other air moving applications User Interface: 0 VDC, remote or on-board potentiometer /(' GLVSOD\ LQGLFDWHV 530 DQG SHUFHQW RI GHPDQG Powered off any line voltage from 115V-277V no separate transformer required 530 PLQLPXP VSHHG 2SWLRQDO UHPRWH SRWHQWLRPHWHU FXVWRPHU VXSSOLHG allows control from up to 50' away Motor:
HVACR RESCUE Permanent Split Capacitor PEP® +LJK (I¿FLHQF\ &RQGHQVHU )DQ 5.6" Diameter, Totally Enclosed, Air Over (TEAO) HVACR OEM APPLICATIONS: +LJK HI¿FLHQF\ 36& PRWRUV IRU FRQGHQVHU IDQV FEATURES: (I¿FLHQF\ 'HVLJQ ) & $PELHQW 'HVLJQ %DOO %HDULQJV +DYH $OO $QJOH 7KUXVW 6\VWHP &ODVV ) ,QVXODWLRQ 'HVLJQHG )RU 8VH :LWK 9 &DSDFLWRUV %DOO %HDULQJ /HDGV +XEOHVV /HDG (QG 'UDLQ +ROHV %RWK (QGV 5HYHUVLEOH 5RWDWLRQ $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU &RQWLQXRXV 'XW\ HVACR HVACR HVA
HVACR RESCUE HVACR OEM Permanent Split Capacitor MOJAVE® Series Condenser Fan 5.6" Diameter, Totally Enclosed, Air Over (TEAO) APPLICATIONS: Residential and commercial condensing unit fan motors in extreme temperature locations. ) & $PELHQW 'HVLJQ %DOO %HDULQJV +DYH $OO $QJOH 7KUXVW 6\VWHP &ODVV ) ,QVXODWLRQ 'HVLJQHG )RU 8VH :LWK 9 &DSDFLWRUV ([WHQGHG 6WXGV /HDGV +XEOHVV /HDG (QG 'UDLQ +ROHV %RWK (QGV 5HYHUVLEOH 5RWDWLRQ $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU &
HVACR RESCUE OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Type Dia. HP Volts RPM Speed Amps Rotation Bearing Enclosure Cross Reference Notes Fig HVACR HVACR OEM OEM Catalog Number AAON $SSOLFDWLRQ &RPPHUFLDO &RQGHQVHU )DQ PSC 5.6" 3/4 460 1075 1 2.7 REV ENCL. SHFT END K55HXTSD9941, F4837A27, F48SPP6V9, OAN1076, R1747B, R17470 98"Leads A TEAO C61148-2, KA55HXDNN-577, 5KCP39CGD588BS 35" Leads B ENCL END SHIELD L/E K33HXCDR-934, 10292803 BALL 1954 PSC 5.
HVACR RESCUE HVACR HVACR OEM OEM OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Catalog Number Type Dia. HP Volts RPM Speed Amps Cross Reference Rotation Bearing Enclosure Notes Fig HVACR CARRIER $SSOLFDWLRQ &RPPHUFLDO &RQGHQVHU )DQ 1816 Polyphase 6.3" 1 200-230/460 1140 1 6.0/3.0 REV BALL ODP HD52VE214, 5K49N6084S Rain Shield D CA3407 PSC 5.6" 1/15 208-230 800 1 0.7 CWLE SAB TEAO 5KCP39BGZ038S, K55HXKNR-0234 37" Leads E CA3411 PSC 5.6" 1/15 208-230 1125 1 0.
HVACR RESCUE OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Type Dia. HP Volts RPM Speed Amps Rotation Bearing Enclosure Cross Reference Notes Fig HVACR HVACR OEM OEM Catalog Number CARRIER $SSOLFDWLRQ )DQ &RLO 5.6" 1/3 208-230 1600 1 2 CCWLE SAB OAO 5KCP39FGZ041S, K55HXKMW-0212 CA3414 PSC 5.6" 1/2 115 1075 4 7.9 CCWLE SAB OPEN 5KCP39FGZ041S, K55HXKNH-0226 15" LeadsDouble Shaft N CA3415 PSC 5.6" 3/4 115 1075 4 10.
HVACR RESCUE HVACR HVACR OEM OEM OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Catalog Number Type Dia. HP Volts RPM Speed Amps Cross Reference Rotation Bearing Enclosure Notes Fig 1391 PSC 5.0" 1/4 208-230 1050 3 1.5 REV SAB OPEN 391, D151, A6262, 5002-M, 3400A312 33" Leads Q 1390 PSC 5.0" 1/4 115 1050 3 2.
HVACR RESCUE OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Type Dia. HP Volts RPM Speed Amps Cross Reference Rotation Bearing Enclosure Notes Fig HVACR HVACR OEM OEM Catalog Number DUNHAM BUSH $SSOLFDWLRQ &RPPHUFLDO &RQGHQVHU )DQ 1 200-230/460 1140 1 3.5-3.3/1.7 REV OPEN P55SYTLN1326, MM-2860-305 OAO OFC1024, 747, 326P451, K48HXCCA-1279, D258, M10 SAB ODP BALL W Double Shaft X HVACR KITS Polyphase 5.
HVACR RESCUE HVACR HVACR OEM OEM OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Catalog Number Type Dia. HP Volts RPM Speed Amps Cross Reference Rotation Bearing Enclosure Notes Fig OAO K55HXHN4370, KCP39KG1369S, 3001, 82001, M-Z-008, F112, D801 32" Leads C1 36" Leads F1 7232 PSC 5.6" 1/3 208-230 1625 1 COOLING TOWER DUTY GENERAL PURPOSE SINGLE PHASE AGRICULTURE REV SAB 1645 PSC 5.6" 1/6 208-230 1550 1 1.
HVACR RESCUE OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Type Dia. HP Volts RPM Speed Amps Cross Reference Rotation Bearing Enclosure Notes Fig HVACR HVACR OEM OEM Catalog Number IEC $SSOLFDWLRQ 3DFNDJH 7HUPLQDO $LU &RQGLWLRQHU 5.0" 1/30 115 1100 3 0.73 CCWLE BALL OAO 70556301 Terminal Block K1 4125 PSC 5.0" 1/30 115-127 1100 3 0.53 CCWLE SAB OAO 5KCP29BK5875S, 70021692 48" Leads L1 1269 PSC 5.0" 1/30 115-127 1600 3 0.
HVACR RESCUE HVACR HVACR OEM OEM OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Catalog Number Type Dia. HP Volts RPM Speed Amps Rotation Bearing Enclosure Cross Reference Notes Fig 1725 1 5.0/2.5 REV BALL ODP 23G3901, P63PYCJD2723 56HZ Frame S1 200-230/460 1725 1 7.6-7.8/3.9 REV BALL ODP 23G4001, P63TYCJE2724 56HZ Frame Q1 3 200-230/460 1725 1 9.0-9.2/4.6 REV BALL ODP 23G4101, P63MZCJF2725 56HZ Frame Q1 D5PA2A Polyphase 9.0" 5 208-230/460 1760 1 13.812.6/6.
HVACR RESCUE OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Dia. HP Volts RPM Speed Amps Rotation Bearing Cross Reference Encl Notes Fig HVACR HVACR OEM OEM Catalog Number Type LENNOX $SSOLFDWLRQ &RQGHQVHU )DQ PSC 5.6" 1/6 208-230 825 1 1.1 CCWLE BALL TEAO 65G6001, K55HXDUY1263, K55HXGCE8094 1901 PSC 5.0" 1/6 208-230 1075 1 1 REV SAB TEAO K48HXEMG3494, 31L1901 LX7925 PSC 5.
HVACR RESCUE HVACR HVACR OEM OEM OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Catalog Number Type Dia. HP Volts RPM Speed Amps Rotation Bearing Enclosure Cross Reference Notes Fig 8052 PSC 5.6" 1/3 230 825 3 1.9 CCWLE SAB OAO 65G5901, KA55XJAK2549, 5KCP39NGM981AS LX7920 PSC 5.6" 1/2 115 1075 5 8 CCWLE SAB OAO 60L2201, K55HXHGB-8639, K55HXDUD-1245 43" Leads D2 LX7921 PSC 5.
HVACR RESCUE OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Type Dia. HP Volts RPM Speed Amps Rotation Bearing Enclosure Cross Reference Notes Fig HVACR HVACR OEM OEM Catalog Number MCQUAY $SSOLFDWLRQ %ORZHU 0RWRU PSC 5.6" 1/4 115 1020 1 4.5 CWLE BALL ODP K55HXMDP4133, 057076501 F2 HVACR 4153 MILLER $SSOLFDWLRQ 'LUHFW 'ULYH %ORZHU 5.0" 1/6 115 1050 1 2.6 CCWLE SAB OAO D156, 326, 301543, 305313 24" Cord and Plug G2 2867P PSC 5.
HVACR RESCUE HVACR HVACR OEM OEM OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Catalog Number Type Dia. HP Volts RPM Speed Amps Rotation Bearing Enclosure Cross Reference Notes Fig 51-20761-91 41" Leads J2 K2 J2 5456 PSC 5.6" 1/8 208-230 825 1 1.2 REV SAB TEAO 9735 PSC 5.6" 1/8 208-230 825 2 2.8 CCWLE SAB OAO 51-21276-01, 51-2127602, 51-20763-01, 51-2076091, 14" Leads, K55MFG6350, K55PAK7253, K55DNW9833 5457 PSC 5.6" 1/6 208-230 825 1 1.
HVACR RESCUE OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Type Dia. HP Volts RPM Speed Amps Rotation Bearing Enclosure Cross Reference Notes Fig 50/60 HZ R2 HVACR HVACR OEM OEM Catalog Number TECUMSEH $SSOLFDWLRQ &RPPHUFLDO &RQGHQVHU )DQ Polyphase 5.6" 1/3 380/460 1400/1600 1 1 REV BALL OAO P55SYNP-387, 810E249A88 HVACR 2387 TECUMSEH $SSOLFDWLRQ &RQGHQVHU )DQ 5.0" 1/20 230 1300/1500 1 0.
HVACR RESCUE HVACR HVACR OEM OEM OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Catalog Number Type Dia. HP Volts RPM Speed Amps Rotation Bearing Enclosure Cross Reference Notes Fig K48HXBHZ-955, K48HXSTY-3509, Trane 44" Leads X70500149-02 1676 PSC 5.0" 1/20 115 1100 3 0.55 CWLE SAB OAO 1105 PSC 5.0" 1/16 115 850 3 1.1 CWLE SAB OAO K48HXCFC1327, X70500264-01 U2 1678 PSC 5.0" 1/16 277 850 3 0.5 CWLE SAB OAO K48HXCNN1468, X70500269-01, MOT2852 Y2 1090 PSC 5.
HVACR RESCUE OEM Replacement for 6SHFL¿F 0DQXIDFWXUHUV Type Dia. HP Volts RPM Speed Amps Rotation Bearing Enclosure Cross Reference Notes Fig HVACR HVACR OEM OEM Catalog Number YORK $SSOLFDWLRQ &RQGHQVHU )DQ 1/5 208-230 1075 1 1.3 CWLE SAB OAO F47BGM927, D1041, S2091 1743 PSC 5.6" 1/4 208-230 850 1 1.5 CWLE SAB TEAO 17435, 024-27596-00, K55HXKWA-9803 2553 PSC 5.6" 1 460 1100 3 3.
HVACR RESCUE HVACR HVACR OEM OEM Shaded Pole Unit Bearing Fan Totally Enclosed APPLICATIONS: Evaporator or condenser fan motors to meet manufacturer’s requirements for refrigerated display cases and vending machines. 3HUPDQHQWO\ OXEULFDWHG EHDULQJV ,QGLYLGXDOO\ ER[HG ,PSHGDQFH SURWHFWHG : 8QGHU $UH +HUW] 5DWHG 6XLWDEOH )RU $OO $QJOH 2SHUDWLRQ &RUG :LWK 0ROGHG 6WUDLQ 5HOLHI &DVW ,URQ +RXVLQJ ,QFOXGHV YLEUDWLRQ GDPSHQHU KXE ZDVKHU VSHHG QXW 4 mounting screws (2 to 35 watt)
HVACR RESCUE Shaded Pole & PSC Direct Drive Fan 3.3" Diameter, Open and Totally Enclosed Designs HVACR HVACR OEM OEM APPLICATIONS: +LJK HI¿FLHQF\ 36& PRWRUV IRU UHIULJHUDWLRQ HYDSRUDWRU DQG JHQHUDO SXUSRVH 9662 9657 FEATURES: )RXU [ 6WXG ([WHQVLRQV $W (DFK (QG %DOO %HDULQJV +DYH $OO $QJOH 7KUXVW 6\VWHP $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU DQG IHDWXUH GXDO SOXJ FRUG IRU ÀH[LELOLW\ 'XDO 6WXGV 36& 'HVLJQ ZLWK &DSDFLWRU ,QFOXGHG /HDGV HVACR HVACR KITS Open
Condenser Fan Offering Overview Motor Types Offered: 42 Frame (5" diameter) Clam Shell RESCUE EZ-FIT® Refrigeration OEM replacements U.S. MOTORS Brand Condenser Fans ® Built to the most exacting standards in the industry. More importantly to not create a call back and start up after the off season. 48 Frame (5.6" diameter) PEP® HI¿FLHQW MOJAVE® (70°C/158°F rated ambient) RESCUE® (The Ultimate Truck Stock Motorr™) 56 Frame (6.
HVACR RESCUE Permanent Split Capacitor Condenser Fan 5.0" Diameter, Totally Enclosed, Air Over (TEAO) HVACR OEM APPLICATIONS: Residential condensing unit fan motor.
HVACR RESCUE HVACR OEM Refrigeration Condenser Fan 5.0" and 5.6" Diameter Open Drip-Proof, Totally Enclosed, Air Over and Open Air Over APPLICATIONS: Condenser cooling fan motors to meet manufacturer’s requirements for commercial refrigeration units. 2(0 'LUHFW 5HSODFHPHQWV 6LQJOH 6SHHG $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU 'HVLJQHG IRU XVH ZLWK 9 &DSDFLWRUV HVACR KITS HVACR HVACR FEATURES: AGRICULTURE GENERAL PURPOSE SINGLE PHASE COOLING TOWER DUTY Figure A 5.
HVACR RESCUE Permanent Split Capacitor Condenser Fan 5.6" Diameter, Open Drip-Proof, Air Over HVACR OEM APPLICATIONS: Designed to meet manufacturer’s requirements for condenser cooling fans. FEATURES: +LJK (I¿FLHQF\ (CONOMIZER® Rated (except as noted) +] & DSDFLWRU 0RXQWLQJ +ROHV LQ )UDPH %DQG &RQWLQXRXV 'XW\ $LU 2YHU :DWHU 6OLQJHU 'HVLJQHG IRU XVH ZLWK 9 &DSDFLWRUV $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU %HDULQJV KDYH $OO $QJOH 7KUXVW 6\VWHP *UHHQ *URXQG /HDG 5HYHUVLEOH 5RWDWLRQ &ODVV % ,QV
HVACR RESCUE HVACR OEM Permanent Split Capacitor Condenser Fan 5.6" Diameter, Totally Enclosed, Air Over (TEAO) APPLICATIONS: Residential and commercial condensing unit fan motors to meet manufacturer’s requirements. ) & $PELHQW 'HVLJQ %HDULQJV KDYH $OO $QJOH 7KUXVW 6\VWHP &ODVV % ,QVXODWLRQ 'HVLJQHG IRU XVH ZLWK 9 &DSDFLWRUV ([WHQGHG 6WXGV /HDGV +XEOHVV /HDG (QG 'UDLQ +ROHV %RWK (QGV 5HYHUVLEOH 5RWDWLRQ $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU &RQWLQXRXV 'XW\ Stu
HVACR RESCUE Permanent Split Capacitor Condenser Fan 5.6" Diameter, Totally Enclosed, Air Over (TEAO) (continued) HVACR OEM Amps 2.4-1.4 2.0 1.0 1.1 2.0 2.0 2.0 1.3 2.2 1.6 1.9 / 1.2 1.8 2.0 2.6 / 1.8 2.8 1.6 3.1 3.1 1.5 1.3 1.0 2.9 3.0 1.0 3.0 / 1.3 4.7 4.7 2.0 1.8 1.25 Shaft N 6.0 6.0 6.0 5.0 5.0 3.7 5.0 6.0 6.0 5.0 5.0 5.0 5.0 5.0 6.0 6.0 6.0 6.0 6.0 5 5.0 6.0 5.0 6.5 5.0 5.0 5.0 6.0 5.0 5.0 Shell XI 5.1 5.4 5.6 5.3 4.6 4.1 4.6 5.4 4.8 4.6 5.3 4.6 4.1 4.6 6.4 6.3 5.3 5.3 5.9 6.4 6.4 4.3 5.1 5.3 5.
HVACR RESCUE HVACR OEM Permanent Split Capacitor Condenser Fan 5.6" Diameter, Open Drip-Proof, Air Over APPLICATIONS: For use on condenser cooling fans. AGRICULTURE GENERAL PURPOSE SINGLE PHASE COOLING TOWER DUTY HVACR KITS HVACR HVACR FEATURES: +LJK (I¿FLHQF\ (FRQRPL]HUU® Rated (except as noted) RU /HDGV XQOHVV RWKHUZLVH QRWHG 'RXEOH )ODWV RQ 6KDIW²(FRQRPL]HUU® Models &DSDFLWRU 0RXQWLQJ +ROHV LQ )UDPH %DQG 'HVLJQHG IRU XVH ZLWK 9 &DSDFLWRUV $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3U
HVACR RESCUE Permanent Split Capacitor Commercial Condenser Fan Open Drip-Proof & Totally Enclosed, Air Over HVACR OEM APPLICATIONS: For use on condenser cooling fans in commercial air conditioning applications. FEATURES: & $PELHQW 'XDO 9ROWDJH &ODVV % ,QVXODWLRQ & DSDFLWRU DQG 2XWOHW %R[ ,QFOXGHG XQOHVV QRWHG 5HYHUVLEOH 5RWDWLRQ 'RXEOH 6HDOHG %DOO %HDULQJV &RQWLQXRXV 'XW\ $LU 2YHU $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU HVACR HVACR Figure A Figure B HP 1/3 1/2 Catalog
HVACR RESCUE HVACR OEM Three Phase Commercial Condenser Fan Open Drip-Proof, Air Over APPLICATIONS: Designed to meet manufacturer’s requirements for condenser cooling fans in commercial air conditioning applications where 3 phase power is required. $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU 5HYHUVLEOH 5RWDWLRQ &RQWLQXRXV 'XW\ $LU 2YHU 'RXEOH 6HDOHG %DOO %HDULQJV 'XDO 9ROWDJH &ODVV % ,QVXODWLRQ ) & $PELHQW 5DWHG 6KDIW XS 0RXQWLQJ Belly Band Mount, Flat and Keyway on Shaft HP 1/2
HVACR RESCUE Three Phase MOJAVE® Series Commercial Condenser Fan Open Drip-Proof, Air Over HVACR OEM APPLICATIONS: Designed to meet manufacturer's requirements for condenser cooling fans in commercial air conditioning applications where 3 phase power id required.
HVACR RESCUE HVACR OEM Three Phase VariTough® Inverter Duty Commercial Condenser Fan, Open Air Over APPLICATIONS: For use on condenser cooling fans in commercial refrigeration applications, where 3 phase power and variable frequency drives (VFD’s) are required. C ,QYHUWHU 'XW\ 'HVLJQHG WR 1(0$ 0* 3DUW 2SHQ 'ULS 3URRI 6KDIW XS 'HVLJQ & $PELHQW &RQWLQXRXV 'XW\ $LU 2YHU 'RXEOH 6HDOHG %DOO %HDULQJV Includes Shaft Ground Ring 3DWHQWHG 9ROWDJH &KDQJH 'HYLFH /RFN %HDULQJ 6\VW
HVACR RESCUE 21/29 Frame Replacement Motor 5.0" Diameter, Open Drip-Proof, Air Over HVACR OEM APPLICATIONS: Designed to replace most original 21 and 29 frame GE®† motors.
HVACR RESCUE HVACR OEM Direct Drive Fan Single & Double Shaft 5.0" Diameter, Open, Air Over O APPLICATIONS: Designed to meet manufacturer’s requirements for direct drive fans & blowers. %HDULQJV +DYH $OO $QJOH 7KUXVW 6\VWHP &RQWLQXRXV 'XW\ $LU 2YHU " Line Leads Unless Otherwise Noted $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU &RQQHFWLRQ ,QIRUPDWLRQ )XUQLVKHG LQ WKH 1DPHSODWH 'DWD 6KDGHG 3ROH 'HVLJQ ([FHSW :KHUH 1RWHG AGRICULTURE GENERAL PURPOSE SINGLE PHASE COOLING TOWER DUTY HVACR KIT
HVACR RESCUE Permanent Split Capacitor Direct Drive Fan Single Shaft 5.0" Diameter, Open, Air Over HVACR OEM APPLICATIONS: Designed to meet manufacturer’s requirements for use on direct drive fan & blowers. FEATURES: 5HYHUVLEOH 8QOHVV 1RWHG %HDULQJV +DYH $OO $QJOH 7KUXVW 6\VWHP 'HVLJQHG IRU 8VH ZLWK 9 &DSDFLWRUV &RQWLQXRXV 'XW\ $LU 2YHU " Line Leads Unless Otherwise Noted $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU &RQQHFWLRQ DQG &DSDFLWRU ,QIRUPDWLRQ )XUQLVKHG in the Nameplate Data HVACR HVACR
HVACR RESCUE HVACR OEM Permanent Split Capacitor Packaged Terminal A/C – Heat Pump Open, Air Over APPLICATIONS: Designed to meet manufacturer's requirements for use in package terminal air conditioners or heat pump units. %HDULQJV +DYH $OO $QJOH 7KUXVW 6\VWHP 'HVLJQHG IRU XVH ZLWK 9 &DSDFLWRUV &RQWLQXRXV 'XW\ $LU 2YHU $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU A B 1/16 1/15 1/12 1/5 1/4 TR = Trane COMMERCIAL DUTY PUMP RESIDENTIAL WATER SYSTEM PUMP AGRICULTURE HP 1/15 1/30 1/20
HVACR RESCUE C–H Permanent Split Capacitor Packaged Terminal A/C Heat Pump Open, Air Over (continued) HVACR OEM E F HVACR HVACR Dual Shaft, Direct Drive Blower - 5.0" Diameter TR = Trane IE = IEC Catalog Number 1090 1256 1960 1964 8525 1210 1257 1192 1353 1279 Cap MFD 5.0 6.0 5.0 4.0 5.0 5.0 7.5 7.5 5.0 5.0 Amps 0.80 1.40 0.69 0.80 2.20 1.80 2.50 2.30 1.2 1.40 Shaft N 9.7 8.3 8.3 8.3 9.4 8.3 8.3 10.0 9.2 9.0 Shaft XN 10.8 8.3 7.6 7.8 9.4 8.0 8.3 10.0 9.2 9.0 Total Length 25.4 21.9 21.2 21.
HVACR RESCUE HVACR OEM Permanent Split Capacitor Packag Packaged Terminal A/C-Heat Pump 5.6" Diameter, Op Open, Air Over (continu nued) K HVACR HVACR J HVACR KITS Dual Shaft, Direct Drive Blower - 5.6" Diameter HP 1/8 1/5 RPM / Spds. 1075/3 1040/3 Voltage 277 277/265 Catalog Number 1042 3360 Cap MFD 5 3 Amps 0.76 1.30 Shaft N 88.44 7.0 Shaft XN 8.4 3.0 Total Length 21.7 13.8 Mount Hub Ring Lug Fig. J K Rotation CCWLE CWLE Ship Wt. 9 14 OEM CA U.S.
HVACR RESCUE Permanent Split Capacitor Double Shaft Fan & Blower 5.
HVACR RESCUE HVACR OEM Permanent Split Capacitor Direct Drive Fan & Blower 5.6" Diameter, Open, Air Over APPLICATIONS: Residential and commercial direct drive fans and blowers. 6WXG ([WHQVLRQV 2Q 3RSXODU 0RGHOV 'HVLJQHG IRU XVH ZLWK 9 &DSDFLWRUV &ODVV % ,QVXODWLRQ " Leads &RQWLQXRXV 'XW\ $LU 2YHU %HDULQJV +DYH $OO $QJOH 7KUXVW 6\VWHP 5HYHUVLEOH 5RWDWLRQ )RU )OH[ 0RXQW 2UGHU &DWDORJ 6HH 3DJH 63 $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU &RQQHFWLRQ DQG &DSDFLWRU ,QIRUPDWLR
HVACR RESCUE Permanent Split Capacitor Direct Drive Fan & Blower 'LDPHWHU 2SHQ $LU 2YHU +LJK (I¿FLHQF\ HVACR OEM APPLICATIONS: Designed to meet manufacturer’s requirements for use on direct drive fans & blowers. FEATURES: $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU &RQQHFWLRQ DQG &DSDFLWRU ,QIRUPDWLRQ )XUQLVKHG in the Nameplate Data :KHQ )XUQLVKHG WKH &DSDFLWRU DQG ,WV 0RXQWLQJ Hardware is Supplied Detached " Dia.
HVACR RESCUE HVACR OEM Permanent Split Capacitor Flex Mount Direct Drive Fan & Blower 5.0" & 5.6" Diameter, Open, Air Over APPLICATIONS: 'HVLJQHG WR PHHW PDQXIDFWXUHU¶V UHTXLUHPHQWV IRU XVH RQ GLUHFW GULYH IDQ EORZHUV ZLWK ÀH[LEOH HDU PRXQWV &ODVV % ,QVXODWLRQ 8QOHVV 1RWHG " Diameter Motors CWLE Rotation " Diameter Motors Reversible Rotation %HDULQJV $OO $QJOH 7KUXVW 6\VWHP &RQWLQXRXV 'XW\ $LU 2YHU " Leads $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU 36& 0RWRUV 'HVLJQHG )RU
HVACR RESCUE Permanent Split Capacitor Unit Heater Fan 5.6" & 6.3" Diameter, Totally Enclosed, Air Over HVACR OEM APPLICATIONS: Designed to meet manufacturer’s requirements for use on unit heaters. FEATURES: HVACR HVACR &RQWLQXRXV 'XW\ $LU 2YHU 5HYHUVLEOH 0RWRUV $UH (DVLO\ 5HYHUVHG With Quick Connects " Diameter Hub Rings When Furnished $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU *UHHQ *URXQG /HDG )UDPH +DV 1) $ 7KUHDG 56 Frame Has 10-32 NF-2A Thread 9 &DSDFLWRU ,V )XUQ
HVACR RESCUE HVACR OEM Split Phase Belted Fan & Blower NEMA A®† 48 Frame, Single & Two Speed APPLICATIONS: Designed to meet manufacturer’s requirements for belted fans and blowers.
HVACR RESCUE Split Phase Belted Fan & Blower Open Drip-Proof, NEMA A®† 56 Frame, Single & Two Speed HVACR OEM APPLICATIONS: Designed to meet manufacturer’s requirements for belted fans and blowers.
HVACR RESCUE HVACR OEM Capacitor Start Belted Fan & Blower Open Drip-Proof, Resilient Base APPLICATIONS: Designed to meet manufacturer’s requirements for belted fans and blowers.
HVACR RESCUE Three Phase Commercial Belt-Drive Blower Motor Open Drip-Proof, Air Over Not Required HVACR OEM APPLICATIONS: Designed to meet manufacturer’s requirements for belt-drive blowers in commercial air conditioning applications where 3 phase power is required. FEATURES: $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU 5HYHUVLEOH 5RWDWLRQ &RQWLQXRXV 'XW\ 'RXEOH &RQWDFW 6HDOHG %DOO %HDULQJV 'XDO 9ROWDJH &ODVV % ,QVXODWLRQ ) & $PELHQW HVACR HVACR HVACR KITS HP 1 Bearings Bal
HVACR RESCUE HVACR OEM Split Phase Evaporative Cooler 6.3" Diameter, Open Drip-Proof APPLICATIONS: Designed to meet manufacturer’s requirements for belt driven evaporative cooling units. Ball Bearings &ODVV B Insulation &: 5RWDWLRQ 6KDIW (QG &RUURVLRQ 5HVLVWDQW 5RWRU &RUH $QG $FWXDWRU $VVHPEO\ ,QGXVWU\ 6WDQGDUG +XE 7R +XE 'LPHQVLRQ $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU CLOSE COUPLED PUMP COMMERCIAL DUTY PUMP RESIDENTIAL WATER SYSTEM PUMP GENERAL PURPOSE THREE PHASE AGRICULTURE GENE
HVACR RESCUE Split Phase and Capacitor Start Oil Burner Totally Enclosed When Mounted HVACR OEM APPLICATIONS: Designed to meet manufacturer’s requirements for oil burners. FEATURES: 1 )UDPH +DV +ROHV $QG 6FUHZV For Mounting Outlet Box 1 )ODQJH ,V (QFORVHG 0 $QG 1 Flange Are Ventilated %HDULQJV +DYH $OO $QJOH 7KUXVW 6\VWHP HVACR HVACR & $PELHQW " Leads, Located At 3 O’clock Viewed From End Opposite Shaft 6HUYLFH )DFWRU 5HYHUVLEOH 5RWDWLRQ ([FHSW $V 1RWHG 0DQXDO 5HVH
HVACR RESCUE HVACR OEM Permanent Split Capacitor Ventilation Direct Drive Blower 5.0" & 5.6" Diameter, Open, Air Over APPLICATIONS: Designed to meet manufacturer’s requirements for direct drive ventilation units. &DSDFLWRU ,QFOXGHG $QG 0RXQWHG 2Q 36& 0RGHOV $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU &RQWLQXRXV 'XW\ %DOO %HDULQJV 8QOHVV 1RWHG & $PELHQW 5DWHG 6HUYLFH )DFWRU GENERAL PURPOSE SINGLE PHASE COOLING TOWER DUTY HVACR KITS HVACR HVACR FEATURES: HP 1/12 1/6 1/3 3/4 Voltag
HVACR RESCUE Permanent Split Capacitor Ventilation Direct Drive Blower 5.0" & 5.6" Diameter, Open, Air Over (continued) HVACR OEM APPLICATIONS: Designed to meet manufacturer’s requirements for direct drive ventilation units. FEATURES: HVACR HVACR %DOO %HDULQJV 8QOHVV 1RWHG & $PELHQW 5DWHG 6HUYLFH )DFWRU &DSDFLWRU ,QFOXGHG $QG 0RXQWHG 2Q 36& 0RGHOV $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU &RQWLQXRXV 'XW\ HVACR KITS 1/3 1/2 RPM/ Spd.
HVACR RESCUE HVACR OEM Split Phase Ventilation Direct Drive Blower 5.6" or 6.3" Diameter, Open Drip-Proof, Air Over APPLICATIONS: Design to meet manufacturer’s requirements for direct drive ventilation units with a C-Face mount. &RQWLQXRXV 'XW\ 5HYHUVLEOH 5RWDWLRQ &ODVV % ,QVXODWLRQ 7KUHDGHG &RQGXLW +ROH ,QWHUQDO &RQGXLW %R[ 2SSRVLWH 6KDIW (QG .H\ZD\ 2Q 6KDIW 'LDPHWHU 8QOHVV 1RWHG HVACR KITS HVACR HVACR FEATURES: HP 1/3 RPM 850 Voltage 115 Catalog Number 1208 NEMA Frame 56CZ
HVACR RESCUE Ventilation Circulator Motor Yoke Mount Fan Motors HVACR OEM APPLICATIONS: Designed to meet manufacturer’s requirements for air circulators where motor is mounted directly to fan column. FEATURES: &RQWLQXRXV 'XW\ 36& 0RGHOV ,QFOXGH &DSDFLWRU 0RXQWHG :LWK &RYHU &ORFNZLVH 'ULYH (QG 5RWDWLRQ $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWLRQ 6WXGV )RU 0RXQWLQJ )DQ *XDUG 6HUYLFH )DFWRU ([FHSW :KHUH 1RWHG 7HUPLQDO %RDUG :LWK 6LGH &RQGXLW 3OXJ 8QOHVV 1RWHG HVACR HVACR Yoke Mount, W
HVACR RESCUE Accessories Kit Number Description Quantity Per Kit 1 Shaft Conversion Set. Each set includes 1 shaft adapter and 1 key (converts 1/2" shaft to 5/8" key) 10 sets 9 Steel Banded Hub ring set — 2 1/4" diameter (2 per set) 1 set 10 Steel Banded Hub ring set — 2 1/2" diameter (2 per set) 1 set 13 Belly Band Mount adjustable ear mount for 5.0" and 5.
HVACR RESCUE Accessories 3URYLGH PD[LPXP ÀH[LELOLW\ LQ DSSO\LQJ VWDQGDUG UHSODFHPHQW PRWRUV WR YDULRXV DSSOLFDWLRQV Quantity Per Kit Description 1 set 28 Drip shield for condenser fan motors — 6 3/8" dia. with 5/8" diameter shaft hole for NEMA 42, 48 or 56Z frame motors 1 shield 29 Direct drive blower mounting ring set - double wire type Each set includes motor support ring - 4 rubber mounting bushings with sleeves and mounting screws For 5.6" diameter motor - 16" B.C.
® RESCUE ECOTECH Motors 8S WR (I¿FLHQW ± ± 25% increase LQ SHDN HI¿FLHQF\ FRPSDUHG WR PSC blower motors Exclusive Speed-Sensing Technology – Connects just like a traditional PSC motor ® RESCUE ECOTECH Blower & Fan Motors RESCUE ECOTECH ® motors drop into existing permanent split capacitor blower applications without FRPSOH[ ZLULQJ PRGL¿FDWLRQV RU WLPH FRQVXPLQJ changes to the system controls. Utilizing our exclusive speed-sensing technology, RESCUE ECOTECH® motors can boost your energy HI¿FLHQF\
Cooling Tower Duty Motors For use in Cooling Tower, Evaporative Condenser, and other commercial and industrial applications requiring protection from harsh operating conditions with high humidity. Need something special? Customization is standard with ReadyLine Assembly! ® )HDWXUHV %HQH¿WV $OO VLQJOH VSHHG 3UHPLXP (I¿FLHQW PRGHOV meet NEMA A®† 3UHPLXP HI¿FLHQF\ OHYHOV 7KRXVDQGV RI FRQ¿JXUDWLRQV WR FKRRVH IURP VBXX seal installed on “wet” end for 3UHPLXP (I¿FLHQW PRWRUV Rotor balance better tha
HVACR RESCUE HVACR OEM Stock Cooling Tower Duty Three Phase, TEAO & TEFC 3UHPLXP (I¿FLHQW ,QYHUWHU 'XW\ +] 6SHHG 5DQJH 9DULDEOH 7RUTXH APPLICATIONS: For use in Cooling Tower, Evaporative Condenser and other commercial and industrial applications requiring protection from harsh operating conditions with high humidity. HVACR KITS HVACR FEATURES: ,19(57(5 *5$'(® Motors with Insulation that Exceeds the NEMA®† MG-1 Part 31 Standard 'RXEOH 'LS %DNH 6ROLGV 3RO\HVWHU ,QVXODWLRQ RQ :LQG
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Fan Cooled (7()& 3UHPLXP (I¿FLHQW ,QYHUWHU 'XW\ +] 9DULDEOH 7RUTXe) CTI For use in Cooling Tower, Evaporative Condenser and other commercial and industrial applications requiring protection from harsh operating conditions with high humidity.
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Fan Cooled (7()& 3UHPLXP (I¿FLHQW ,QYHUWHU 'XW\ +] 9DULDEOH 7RUTXe) (continued) HVACR HVACR OEM CTI List A: For mounting positions F1, F2, C1, C2, W1, W2, W3. List B: For mounting positions W5 & W8.
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Fan Cooled (7()& 3UHPLXP (I¿FLHQW ,QYHUWHU 'XW\ +] 9DULDEOH 7RUTXe) (continued) HP 60 Catalog Number HW60V2H HW60V2E HW60V2G HW60V3H HW60V3E HW60V3G HW75V2H HW75V2E HW75V2G HW75V3H HW75V3E HW75V3G HW100V2H HW100V2E HW100V2G HW100V3H HW100V3E HW100V3G List A $8,961 $8,297 $9,541 $16,577 $15,349 $17,652 $10,399 $9,628 $11,073 $19,238 $17,813 $20,485 $15,550 $14,399 $16,559 $28,769 $26,639 $30,634 List B $9,271 $8,607
HVACR RESCUE HVACR OEM ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed )DQ &RROHG 7()& 3UHPLXP (I¿FLent, 2 Speed, 1 Winding APPLICATIONS: CTE For use in Cooling Tower, Evaporative Condenser and other commercial and industrial applications requiring protection from harsh operating conditions with high humidity. 'RXEOH 'LS %DNH 6ROLGV 3RO\HVWHU ,QVXODWLRQ 2Q :LQGLQJV &ODVV ) ,QVXODWLRQ & $PELHQW &DVW ,URQ )UDPH %HDULQJ ,VRODWRUV RQ ZHW HQG IRU YHU
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed )DQ &RROHG 7()& 3UHPLXP (I¿FLent, 2 Speed, 1 Winding (continued) HVACR OEM CTE List A: For mounting positions F1, F2, C1, C2, W1, W2, W3, W4. List B: For mounting positions W5 & W8. * CLOSE COUPLED PUMP Full Load Amps Notes 10.8/28.4 4.8/12.5 3.8/9.9 14.5/40.0 5.8/14.8 4.5/11.5 16.8/43.0 7.7/19.3 6.2/15.4 21.8/43.0 7.6/18.9 10.0/16.0 19.9/56.0 9.1/24.1 7.2/19.2 20.6/55.0 9.1/24.1 7.2/19.5 25.5/68.0 11.1/29.6 9.0/23.8 34.0/70.
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed )DQ &RROHG 7()& 3UHPLXP (I¿FLent, 2 Speed, 1 Winding (continued) HVACR OEM CTE HP HP (Low) 75 / 18 3/4 100 / 25 RPM/RPM Low (# Windings) Voltage 1800/900(1) 200 1800/900(1) 460 1800/900(1) 575 1200/600(1) 200 1200/600(1) 460 1200/600(1) 575 1800/900(1) 200 1800/900(1) 460 1800/900(1) 575 1200/600(1) 200 1200/600(1) 460 1200/600(1) 575 Frame 405T 405T 405T 444T 444T 444T 444T 444T 444T 445T 445T 445T Catalog Number HW75PL9H
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Fan Cooled (7()& 3UHPLXP (I¿FLHQW 2 Speed, 2 Winding 2-100 HP CTE For use in Cooling Tower, Evaporative Condenser and other commercial and industrial applications requiring protection from harsh operating conditions with high humidity. HVACR OEM APPLICATIONS: FEATURES: 'RXEOH 'LS %DNH 6ROLGV 3RO\HVWHU ,QVXODWLRQ 2Q :LQGLQJV &ODVV ) ,QVXODWLRQ & $PELHQW &DVW ,URQ )UDPH %HDULQJ ,VRODWRUV RQ ZHW HQG IR
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Fan Cooled (7()& 3UHPLXP (I¿FLHQW 2 Speed, 2 Winding 2-100 HP (continued) HVACR HVACR OEM CTE List A: For mounting positions F1, F2, C1, C2, W1, W2, W3, W4. List B: For mounting positions W5 & W8.
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Fan Cooled (7()& 3UHPLXP (I¿FLHQW 2 Speed, 2 Winding 2-100 HP (continued) HVACR List A: For mounting positions F1, F2, C1, C2, W1, W2, W3, W4. List B: For mounting positions W5 & W8.
HVACR RESCUE HVACR OEM HVACR HVACR KITS ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Air Over (TEAO) 3UHPLXP (I¿FLHQW Inverter Duty 10:1 (6-60 Hz) Speed Range Variable Torque APPLICATIONS: CTNI For use directly in the airstream in Cooling Tower, Evaporative Condenser and other commercial and industrial applications requiring protection from harsh operating conditions with high humidity. Air velocities per page. FEATURES: 'RXEOH 'LS %DNH 6ROLGV 3RO\H
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Air Over (TEAO) 3UHPLXP (I¿FLHQW Inverter Duty 10:1 (6-60 Hz) Speed Range Variable Torque (continued) HVACR OEM CTNI HVACR List A: For mounting positions F1, F2, C1, C2, W1, W2, W3, W4. List B: For mounting positions W5, W6, W7, W8. * "C" Dim. Ship Wt. Full Load (inches) (lbs) Eff. 16.3 175 91.7 16.3 175 91.7 16.3 175 91.7 22.1 340 91.0 22.1 340 91.7 22.1 340 91.0 22.1 300 92.4 22.1 300 92.4 22.1 300 92.4 24.8 380 91.7 24.
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Air Over (TEAO) 3UHPLXP (I¿FLHQW Inverter Duty 10:1 (6-60 Hz) Speed Range Variable Torque (continued) HVACR HVACR OEM CTNI HP 60 RPM 1800 1800 1800 1200 1200 1200 1800 1800 1800 1200 1200 1200 1800 1800 1800 1200 1200 1200 75 100 AGRICULTURE GENERAL PURPOSE SINGLE PHASE COOLING TOWER COOLING DUTY TOWER DUTY HVACR KITS List A: For mounting positions F1, F2, C1, C2, W1, W2, W3, W4.
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Air Over (TEAO) 3UHPLXP (I¿FLHQW 6SHHG :LQGLQJ CTEN For use directly in the airstream in Cooling Tower, Evaporative Condenser and other commercial and industrial applications requiring protection from harsh operating conditions with high humidity. HVACR OEM APPLICATIONS: FEATURES: 'RXEOH 'LS %DNH 6ROLGV 3RO\HVWHU ,QVXODWLRQ 2Q :LQGLQJV &ODVV ) ,QVXODWLRQ & $PELHQW &DVW ,URQ )UDPH %HDULQJ ,VRODWRUV
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Air Over (TEAO) 3UHPLXP (I¿FLHQW 6SHHG :LQGLQJ (continued) HVACR OEM CTEN CLOSE COUPLED PUMP COMMERCIAL DUTY PUMP RESIDENTIAL WATER SYSTEM PUMP GENERAL PURPOSE THREE PHASE AGRICULTURE GENERAL PURPOSE SINGLE PHASE COOLING TOWER COOLING DUTY TOWER DUTY HVACR KITS HVACR List A: For mounting positions F1, F2, C1, C2, W1, W2, W3, W4. List B: For mounting positions W5, W6, W7, W8.
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Air Over (TEAO) 3UHPLXP (I¿FLHQW 6SHHG :LQGLQJ (continued) HVACR OEM CTEN List A: For mounting positions F1, F2, C1, C2, W1, W2, W3, W4. List B: For mounting positions W5, W6, W7, W8.
HVACR RESCUE HVACR OEM ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Air Over (TEAO) PUHPLXP (I¿FLHQW 2 Speed, 2 Winding 2-100 HP APPLICATIONS: CTEN For use in Cooling Tower, Evaporative Condenser and other commercial and industrial applications requiring protection from harsh operating conditions with high humidity. 'RXEOH 'LS %DNH 6ROLGV 3RO\HVWHU ,QVXODWLRQ 2Q :LQGLQJV &ODVV ) ,QVXODWLRQ & $PELHQW &DVW ,URQ )UDPH %HDULQJ ,VRODWRUV RQ ZHW HQG I
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Air Over (TEAO) PUHPLXP (I¿FLHQW 2 Speed, 2 Winding 2-100 HP (continued) HP HP (Low) 10 (2-1/2) CLOSE COUPLED PUMP Full Load Amps Notes 12.0/27.5 5.2/12.0 4.1/9.8 12.6/29.9 7.2/15.0 5.5/11.3 16.1/44.0 8.9/24.3 5.6/14.8 17.3/43.0 7.5/18.8 5.9/15.0 20.4/56.0 8.9/24.3 7.7/20.4 24.2/62.0 10.9/26.1 8.3/20.2 28.0/71.0 11.2/31.0 8.2/24.0 31.0/73.0 13.0/35.0 11.0/26.7 30.0/81.0 15.2/36.0 11.4/29.3 32.0/86.0 14.4/38.0 11.7/32.0 38.0/118.
HVACR RESCUE ® ReadyLine Cooling Tower Duty Three Phase, Totally Enclosed Air Over (TEAO) PUHPLXP (I¿FLHQW 2 Speed, 2 Winding 2-100 HP (continued) HVACR HVACR OEM CTEN List A: For mounting positions F1, F2, C1, C2, W1, W2, W3, W4. List B: For mounting positions W5, W6, W7, W8.
General Purpose Single Phase For commercial and industrial applications such as pumps, fans, blowers, conveyors and tools.
HVACR RESCUE HVACR OEM General Purpose Single Phase Open Drip-Proof (ODP), Split Phase APPLICATIONS: For commercial and industrial ventilation systems. HVACR FEATURES: & $PELHQW +] 5HYHUVLEOH 5RWDWLRQ &RQWLQXRXV 'XW\ &ODVV $ RU % ,QVXODWLRQ %DOO %HDULQJ GENERAL PURPOSE GEN.
HVACR RESCUE General Purpose Single Phase Totally Enclosed, Fan Cooled (TEFC) Split Phase For commercial fans and blowers, tools, conveyors, pumps and general industrial equipment requiring moderate starting torque. RIGID G BASE S HVACR OEM APPLICATIONS: FEATURES: &ODVV $ RU % ,QVXODWLRQ %DOO %HDULQJ HVACR & $PELHQW +] &RQWLQXRXV 'XW\ Single Speed, Resilient Base Voltage 115 115 115/230 115 115 115 Catalog Number T16B2N49 T14B2N49 T14B3P9 D13B2N4Z 2911 D12B2N4 SF 1.00 1.00 1.00 1.
HVACR RESCUE HVACR OEM General Purpose Single Phase Open Drip-Proof (ODP), Resilient Base, Capacitor Start APPLICATIONS: For air compressors, pumps, conveyors, blowers and general industrial equipment. HVACR FEATURES: &ODVV $ RU % ,QVXODWLRQ 5HYHUVLEOH 5RWDWLRQ & $PELHQW +] &RQWLQXRXV 'XW\ HP 1/6 1/4 1/3 GENERAL PURPOSE GEN.
HVACR RESCUE General Purpose Single Phase Open Drip-Proof (ODP) Rigid Base, Capacitor Start HVACR OEM APPLICATIONS: For air compressors, pumps, conveyors, blowers and general industrial equipment. FEATURES: 'RXEOH 6KLHOGHG %DOO %HDULQJV 5LJLG %DVH 6WDQGDUG &ODVV % ,QVXODWLRQ &RQWLQXRXV 'XW\ 1 Ship Wt. 14.74 16 22 20 24 27 29 20 20 27 23 27 25 24 38 31 31 32 30 35 28 28 31 69 44 31 31 32 39 39 37 40 37 71 36 35 Full Load Amps 3.1/1.5 6 .8/3 .4 8 .8/3 .8-4 .3 6 .5/3 .3 & 7 .3/3 .6 10 .3/4 .8-5 .3 9 .
HP RPM Voltage Frame Catalog Number SF Total Length Ship Wt.
HVACR RESCUE General Purpose Single Phase Open Drip-Proof (ODP), C-Face, Capacitor Start HVACR OEM APPLICATIONS: For air compressors, commercial duty pumps, conveyors, blowers and general industrial equipment. FEATURES: 'RXEOH 6KLHOGHG %DOO %HDULQJV ± /RFNHG 'ULYH (QG %HDULQJV +] 0RWRUV +DYH 6) RQ +] &ODVV % ,QVXODWLRQ &RQWLQXRXV 'XW\ & $PELHQW ) $VVHPEO\ 5HYHUVLEOH 5RWDWLRQ HVACR HVACR KITS Footed Voltage Frame Catalog Number SF Total Length Ship Wt.
HVACR RESCUE HVACR OEM APPLICATIONS: For air compressors, pumps, conveyors, blowers and general industrial equipment. FEATURES: 'RXEOH 6KLHOGHG %DOO %HDULQJV &ODVV % ,QVXODWLRQ &RQWLQXRXV 'XW\ & $PELHQW &DSDFLWRU 6WDUW ,QGXFWLRQ 5XQ ) $VVHPEO\ 5HYHUVLEOH 5RWDWLRQ HP RPM Voltage Frame Catalog Number SF Total Length Ship Wt.
HVACR RESCUE General Purpose Single Phase Totally Enclosed, Fan Cooled (TEFC) Rigid Base, Capacitor Start (continued) HVACR OEM Total Length Ship Wt.
HVACR RESCUE HVACR OEM General Purpose Single Phase Totally Enclosed, Fan Cooled (TEFC) C-Face, Capacitor Start APPLICATIONS: For use on air compressors, commercial duty pumps, conveyors, blowers and general industrial equipment. 'RXEOH 6KLHOGHG %DOO %HDULQJV &ODVV % ,QVXODWLRQ &RQWLQXRXV 'XW\ & $PELHQW &DSDFLWRU 6WDUW ,QGXFWLRQ 5XQ ) $VVHPEO\ 5HYHUVLEOH 5RWDWLRQ +] 0RWRUV +DYH 6 ) RQ +] Footed HP RPM Voltage Frame Catalog Number SF Total Length Ship Wt.
HVACR RESCUE General Purpose Single Phase Totally Enclosed, Fan Cooled (TEFC) C-Face, Capacitor Start (continued) HVACR OEM Footless Ship Wt.
RESCUE Motors ® Multi-Horsepower Rated All Angle Mounting There are many imitations but only ONE RESCUE. Flex Mounting with Kit 44 Belly Band Mounting with Kit 17 ™ Ask for RESCUE,® the EASILY installed, PERMANENT replacement motor that helps YOU save more money. Resilient Mount utilizing 2.5" Hub Rings Exclusive Rheem®† and Ruud®† Side Shell Holes Extended Studs Quiet Bearing System Reversible For more information about the U.S. MOTORS® brand, visit www.usmotors.
Agriculture For use in farm & agriculture duty applications.
HVACR RESCUE HVACR OEM Special Application Agriculture Single Phase, Totally Enclosed, Fan Cooled (TEFC), Ultra High Torque, Capacitor Start APPLICATIONS: For powering agitators, augers, compressors, conveyors, feeders and hay hoists. High torque motors are used on barn cleaners, manure pumps and silo unloaders. GENERAL PURPOSE SINGLE PHASE 3ODVWLF )DQ )DQ &RYHU 'RXEOH 6KLHOGHG %HDULQJV Z /RZ 7HPS *UHDVH 5HJUHDVDEOH 6KDIW (QG 5HPRYDEOH &RQGHQVDWLRQ 'UDLQV )RU 9HUWLFDO 0RXQWLQJ )XOO\ *DVNH
HVACR RESCUE Special Application Agriculture Single Phase, Totally Enclosed, Fan Cooled (TEFC) Agri Duty High Torque, Capacitor Start HVACR OEM APPLICATIONS: For powering agitators, augers, compressors, conveyors, feeders and hay hoists. High torque motors are used on barn cleaners, manure pumps and silo unloaders. FEATURES: &ODVV ) ,QVXODWLRQ )UDPH & $PELHQW &RQWLQXRXV 'XW\ 5HYHUVLEOH 5RWDWLRQ ) $VVHPEO\ 6WHHO )UDPHV 6WHHO :HOGHG %DVH )UDPH 'LH &DVW $OXPLQXP %UDFNHWV :LWK 6WHHO
HVACR RESCUE HVACR OEM Special Application Agriculture Single Phase Aeration Fan & Crop Dryer APPLICATIONS: )RU DLU RYHU DSSOLFDWLRQV RU IDQV PRXQWHG GLUHFWO\ RQ WKH PRWRU VKDIW 6SHFL¿FDOO\ GHVLJQHG IRU XVH RQ YDQH D[LDO FURS GU\HUV DQG DHUDWLRQ IDQV Aeration Fan 7RWDOO\ (QFORVHG $LU 2YHU &ODVV % ,QVXODWLRQ 2Q )UDPH &ODVV ) ,QVXODWLRQ 2Q )UDPH .H\HG 6KDIW 'ULOOHG 2Q &HQWHU 'HHS 7DSSHG 81& = )UDPH 0RWRUV +DYH 'LD ; /RQJ 6KDIW ) $VVHPEO\ 3RVLWLRQ HVACR KITS
HVACR RESCUE Special Application Farm Single & Three Phase Direct Drive Poultry Fan HVACR OEM APPLICATIONS: For direct drive exhaust and vent fans in poultry and livestock houses. FEATURES: &RQWLQXRXV 'XW\ 36& 0RGHOV ,QFOXGH &DSDFLWRU 0RXQWHG :LWK &RYHU &ORFNZLVH 'ULYH (QG 5RWDWLRQ $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWLRQ 6WXGV )RU 0RXQWLQJ )DQ *XDUG 6HUYLFH )DFWRU ([FHSW :KHUH 1RWHG 7HUPLQDO %RDUG :LWK 6LGH &RQGXLW 3OXJ 8QOHVV 1RWHG HVACR HP 1/4 1/2 Frame Catalog Number Amp
HVACR RESCUE HVACR OEM Special Application Farm Single & Three Phase Direct Drive Poultry Fan APPLICATIONS: For direct drive exhaust and vent fans in poultry and livestock houses. %DOO %HDULQJV & $PELHQW 7($2 (QFORVXUH H[FHSW ZKHUH QRWHG &ODVV % ,QVXODWLRQ &RQWLQXRXV $LU 2YHU 'XW\ Single Phase, Permanent Split Capacitor, Resilient Mount HP RPM Voltage Frame Catalog Number Mounting SF Total Length Ship Wt. Full Load Amps Shaft Dim.
HVACR RESCUE Special Application Agriculture Auger Duty Motors For use on augers. HVACR OEM APPLICATIONS: Capacitor Start FEATURES: 7RWDOO\ (QFORVHG )DQ &RROHG H[FHSW ZKHUH QRWHG &ODVV % ,QVXODWLRQ 0DQXDO 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU +3 $ERYH +DYH 2'( 6KDIW ([WHQVLRQ IRU +DQG &UDQN %DOO %HDULQJV < DUH .H\HG <= DUH )ODW 6KDIW 5HYHUVLEOH 5RWDWLRQ )RRWHG H[FHSW ZKHUH QRWHG HVACR HVACR KITS Capacitor Start RPM Voltage Frame Catalog Number SF Total Length Ship
HVACR RESCUE HVACR OEM Special Application Agriculture Agri Duty Fan and Hatcher/Setter Motors APPLICATIONS: Agri duty fans designed for direct drive and vent fans in poultry and livestock houses. Hatcher and setter motors are used in hatchers and setters. Agri Duty Fan Hatcher & Setter AGRICULTURE AGRICULTURE GENERAL PURPOSE SINGLE PHASE COOLING TOWER DUTY HVACR KITS HVACR FEATURES: Agri Duty Fan Motors %DOO %HDULQJV & $PELHQW &RQWLQXRXV 'XW\ 7RWDOO\ (QFORVHG $LU 2YHU 7($2 (QFORVXUH
General Purpose Motors Horsepower: 1 – 500 HP Frame Sizes: 143 through 5811 Phase: Three Phase RPM: 3600, 1800, 1200 or 900 RPM GENERAL PURPOSE MOTORS Voltage: 200 208-230/460 230/460 460 575 Volts Enclosure: Open Drip-Proof (ODP) Totally Enclosed, Fan Cooled (TEFC) Service Factor: 1.15 SF or greater Insulation: Class B or F Insulation (I¿FLHQF\ 3UHPLXP (I¿FLHQW NEMA Premium®† (I¿FLHQW RU (3$FW Nameplate: CE Mark on nameplate (180 Frame or larger) Agency: UL®† Recognized and CSA A®† &HUWL
HVACR RESCUE HVACR OEM General Purpose Three Phase, Open Drip-Proof (ODP) NEMA Premium®† (I¿FLHQW ± ,( APPLICATIONS: For use in pumps, fans, compressors, material handling and other general purpose applications where contaminants are minimal.
HVACR RESCUE General Purpose Three Phase, Open Drip-Proof (ODP) NEMA Premium®† (I¿FLHQW ± ,( (continued) HVACR OEM Full Load Amps 2 1800 1800 1800 1800 1800 1200 1200 1200 900 900 3600 3600 3600 1800 1800 1800 1800 1200 1200 1200 900 900 3600 3600 3600 1800 1800 1800 1200 1200 1200 900 900 3600 3600 3600 1800 1800 1800 1200 1200 1200 208-230/460 230/460 575 208-230/460 208-230/460 200 208-230/460 575 208-230/460 575 200 208-230/460 575 200 208-230/460 575 208-230/460 200 208-230/460 575 208-230/460 5
HP RPM Voltage Frame Catalog Number Total Length Ship Wt. Full Load Eff.
HVACR RESCUE General Purpose Three Phase, Open Drip-Proof (ODP) NEMA Premium®† (I¿FLHQW ± ,( (continued) HVACR OEM Full Load Amps 25 1800 1800 1200 1200 1200 900 900 3600 3600 3600 1800 1800 1800 1800 1800 1800 1200 1200 1200 900 3600 3600 3600 1800 1800 1800 1800 1800 1800 1200 1200 900 900 3600 3600 3600 1800 1800 1800 1800 1800 1800 1800 1200 1200 460 575 200 208-230/460 575 208-230/460 575 200 208-230/460 575 200 208-230/460 575 200 208-230/460 575 200 208-230/460 575 575 200 208-230/460 575 200
HP RPM Voltage Frame Catalog Number Total Length Ship Wt. Full Load Eff.
HVACR RESCUE General Purpose Three Phase, Open Drip-Proof (ODP) NEMA Premium®† (I¿FLHQW ± ,( (continued) HVACR OEM Full Load Eff.
HVACR RESCUE HVACR OEM General Purpose Three Phase, 2SHQ 'ULS 3URRI 2'3 (QHUJ\ (I¿FLHQW 5HVLOLHQW %DVH APPLICATIONS: For use on pumps, fans, compressors, material handling and other general purpose applications where contaminants are minimal. 5ROOHG 6WHHO )UDPH $OXPLQXP (QG 6KLHOGV & $PELHQW RPM Voltage Frame Catalog Number SF Total Length Ship Wt.
HVACR RESCUE General Purpose Three Phase, Totally Enclosed, Fan Cooled (TEFC) UNIMOUNT T® NEMA Premium®† (I¿FLHQW ± ,( HVACR OEM APPLICATIONS: For general industrial equipment including fans, blowers, compressors, pumps and direct connected equipment. FEATURES: & $PELHQW 1(0$ ®† 'HVLJQ % 3HUIRUPDQFH 2Q +HUW] 6LQH :DYH 3RZHU 5HJUHDVDEOH 6KDIW (QG %HDULQJV )UDPH 8S 6HDOHG %HDULQJV )UDPH 'RXEOH 6KLHOGHG )UDPH 6XLWDEOH IRU :\H 'HOWD 6WDUW )UDPH /DUJHU 'XD
HVACR RESCUE General Purpose Three Phase, Totally Enclosed, Fan Cooled (TEFC) UNIMOUNT T® NEMA Premium®† (I¿FLHQW ± ,( HP RPM Voltage Frame Catalog Number SF Total Length Ship Wt. Full Load Eff.
HVACR RESCUE General Purpose Three Phase, Totally Enclosed, Fan Cooled (TEFC) UNIMOUNT T® NEMA Premium®† (I¿FLHQW ± ,( (continued) HVACR OEM Full Load Eff.
HVACR RESCUE General Purpose Three Phase, Totally Enclosed, Fan Cooled (TEFC) UNIMOUNT T® NEMA Premium®† (I¿FLHQW ± ,( HVACR OEM (continued) RPM Voltage Frame Catalog Number SF Total Length Ship Wt. Full Load Eff.
HVACR RESCUE General Purpose Three Phase, Totally Enclosed Fan Cooled (TEFC) UNIMOUNT T NEMA 3UHPLXP (I¿FLHQW – IE3, C-Face Footed ® ®† UT,FUT UTE For use on pumps, fans, compressors, material handling, and other general purpose applications in damp, dusty or dirty environments. HVACR OEM APPLICATIONS: FEATURES: 20 30 SF 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.15 1.15 1.
HVACR RESCUE HVACR OEM 'H¿QLWH 3XUSRVH 7KUHH 3KDVH 81,02817 Totally Enclosed Fan Cooled (TEFC) Multi-Speed ® APPLICATIONS: UT For applications requiring more than one standard speed.
HVACR RESCUE General Purpose Three Phase, Totally Enclosed Fan Cooled (TEFC) Hostile Duty NEMA A 3UHPLXP (I¿FLHQW – IE3 ®† CTE For pulp & paper plants, saw mills, mines, foundries, chemical plants, waste management facilities, and other process-related industries requiring protection within harsh operating conditions. HVACR OEM APPLICATIONS: FEATURES: Ship Wt. Full Load (lbs) Eff. 45 85.5 45 85.5 47 86.5 52 82.5 100 74.0 45 84.0 47 84.0 50 86.5 52 86.5 52 86.5 85 87.5 138 87.5 110 78.5 50 86.
HVACR RESCUE General Purpose Three Phase, Totally Enclosed Fan Cooled (TEFC) Hostile Duty NEMA A 3UHPLXP (I¿FLHQW – IE3 (continued) ® ®† (continued) HVACR OEM CTE HVACR KITS HVACR HP 5 10 15 CLOSE COUPLED PUMP COMMERCIAL DUTY PUMP RESIDENTIAL WATER SYSTEM PUMP GENERAL PURPOSE GEN.
HVACR RESCUE General Purpose Three Phase, Totally Enclosed Fan Cooled (TEFC) Hostile Duty NEMA A 3UHPLXP (I¿FLHQW – IE3 (continued) ® ®† (continued) HP 20 Ship Wt. Full Load (lbs) Eff. 340 91.0 340 91.0 340 91.0 340 93.0 340 93.0 340 93.0 286 91.7 400 91.7 400 91.7 510 89.5 510 89.5 355 91.7 355 91.7 355 91.7 355 91.7 355 93.6 355 93.6 355 93.6 355 93.6 355 93.6 355 93.6 510 93.0 510 93.0 510 93.0 590 89.5 590 89.5 400 91.7 400 91.7 400 91.7 400 91.7 415 93.6 415 93.6 415 93.6 415 93.6 415 93.
HVACR RESCUE General Purpose Three Phase, Totally Enclosed Fan Cooled (TEFC) Hostile Duty NEMA A 3UHPLXP (I¿FLHQW – IE3 (continued) ® ®† (continued) HVACR OEM CTE 50 60 75 CLOSE COUPLED PUMP COMMERCIAL DUTY PUMP RESIDENTIAL WATER SYSTEM PUMP GENERAL PURPOSE GEN.
HVACR RESCUE General Purpose Three Phase, Totally Enclosed Fan Cooled (TEFC) Hostile Duty NEMA A 3UHPLXP (I¿FLHQW – IE3 (continued) ® ®† (continued) HP 75 100 Full Load Amps 174/87 193/97 224/112 90 260 260 225/113 225/113 225/113 90 90 90 248/124 248/124 99 99 262/131 142 114 144 144 144 116 116 151 151 123 123 155 171 137 171 171 171 137 137 181 181 145 145 217 173 224 224 224 181 181 Notes 02,03,09 02,03,NNP 02,03 09 02 02,09 02,03 02,03,09 02,09 02,03,NNP 03 02,03 02,03,09 02 02 02 02,03 02,09 0
HVACR RESCUE 'H¿QLWH 3XUSRVH 7KUHH 3KDVH 7RWDOO\ (QFORVHG )DQ &RROHG 7()& UNIMOUNT , Inverter Duty 10:1 (6-60 Hertz) Speed Range Variable Torque COMMERCIAL DUTY PUMP RESIDENTIAL WATER SYSTEM PUMP GENERAL PURPOSE GEN.
HVACR RESCUE 'H¿QLWH 3XUSRVH 7KUHH 3KDVH 7RWDOO\ (QFORVHG )DQ &RROHG 7()& Hostile Duty, Inverter Duty 10:1 (6-60 Hertz) Speed Range Variable Torque CTI For use on pumps, fans, blowers or other inverter powered applications having variable torque requirements. HVACR FEATURES: ,19(57(5 *5$'(® Insulation System (Meets NEMA®† MG-1 Part 31) &ODVV ) 7KHUPRVWDWV 2QH 3HU 3KDVH &DVW ,URQ )UDPH 5ROOHG 6WHHO &DVW ,URQ (QG %UDFNHWV &RUURVLRQ 5HVLVWDQW 0LOO &KHPLFDO 'XW\ 3DLQW 6WDLQOHVV 6WHHO
HVACR RESCUE 'H¿QLWH 3XUSRVH 7KUHH 3KDVH 7RWDOO\ (QFORVHG )DQ &RROHG 7()& Hostile Duty, Inverter Duty 10:1 (6-60 Hertz) Speed Range Variable Torque (continued) HVACR HVACR OEM CTI 50 60 75 100 125 150 200 RPM (Max Speed) 3600(5400) 1800(2700) 1200(2400) 3600(5400) 1800(2700) 1200(2400) 3600(5400) 1800(2700) 1200(2400) 3600(4500) 1800(3600) 1200(2400) 3600(4500) 1800(3600) 1200(2400) 3600(4500) 1800(3600) 1200(2400) 3600(4500) 1800(3600) 1200(2400) 3600(4500) 1800(3600) Voltage 230/460 230/460
HVACR RESCUE 'H¿QLWH 3XUSRVH 7KUHH 3KDVH 7RWDOO\ (QFORVHG )DQ &RROHG 7()& Hostile Duty, Inverter Duty 10:1 (6-60 Hertz) Speed Range Constant Torque CTI For pumps, fans, blowers or other inverter powered applications having constant torque requirements. All items on this page are assembled to order. Contact your Customer Service representative for lead times.
HVACR RESCUE HVACR OEM 'H¿QLWH 3XUSRVH 7KUHH 3KDVH 2SHQ 'ULSSURRI 2'3 Inverter Duty 10:1 (6-60 Hertz) Speed Range Variable Torque APPLICATIONS: DI, RI For use on pumps, fans, blowers or other inverter powered applications. HVACR KITS HVACR FEATURES: 5HJUHDVDEOH %HDULQJV )UDPH 8S /LIWLQJ 3URYLVLRQV )UDPH 8S 'RXEOH 6KLHOGHG %HDULQJV 2SHQ 2Q )UDPH 'RXEOH 'LS %DNH :LWK ([WUD %UDFLQJ 3UHPLXP (I¿FLHQW 'HVLJQ 6SHFLDO %DODQFH ) $VVHPEO\ 3RVLWLRQ &ODVV ) ,QVXODWLRQ
HVACR RESCUE 'H¿QLWH 3XUSRVH 7KUHH 3KDVH 2SHQ 'ULSSURRI 2'3 Inverter Duty 10:1 (6-60 HZ) Speed Range Variable Torque (continued) HP 75 125 Catalog Number D75V1BS D75V2B D75V3B D100V1BS D100V2B D100V3C D125V1CS D125V2C D150V1BS D150V2C D150V3C D200V2C D250V2C List $8,660 $8,011 $13,029 $11,372 $9,991 $16,135 $14,150 $12,231 $17,212 $17,276 $21,964 $22,322 $32,263 Discount Symbol DS-VFM DS-VFM DS-VFM DS-VFM DS-VFM DS-VFM DS-VFM DS-VFM DS-VFM DS-VFM DS-VFM DS-VFM DS-VFM "C" Dim. (inches) 26.6 29.7 34.
Residential Water System Pump Motors For use on jet pumps, booster pumps, lawn sprinkler pumps, and other centrifugal pump applications.
HVACR RESCUE HVACR OEM Special Application Single Phase, Open Drip-Proof (ODP) Jet Pump, Square Flange & C-Face, Capacitor Start APPLICATIONS: For jet pumps, booster pumps, centrifugal pumps, lawn sprinkler pumps. 6WDLQOHVV 6WHHO 6KDIW & )DFH 81) $ WKUHDG 6TXDUH )ODQJH 81& $ WKUHDG %DOO %HDULQJV /RFNHG 'ULYH (QG %HDULQJ &RQWLQXRXV 'XW\ +] ( = $FFHVV™ Motor Cover & $PELHQW $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU 5RXQG )UDPH :LWKRXW %DVH 1(0$ ®†
Commercial Duty Pump Motors For use on chiller, condensate and other HVACR duty pumps, booster, irrigation, dishwasher and parts washer pumps, along with many other commercial duty applications. Horsepower: 1/4 – 60 HP Phase: Single and Three Phase RPM: 3600, 1800 or 1200 RPM Voltage: Single Phase: 208-230/115 Volts, 50/60 Hz options Three Phase: 208-230/460 and 190/380-415 Volts, 60/50 Hz (575 Volts available) COMMERCIAL DUTY PUMP MOTORS (I¿FLHQF\ 6WDQGDUG (QHUJ\ (I¿FLHQW and Extreme-E® Bolt-On Ba
HVACR RESCUE HVACR OEM Special Application Commercial Pump Single Phase Totally Enclosed, Fan Cooled (TEFC) C-Face APPLICATIONS: For use on chiller, condensate, and other HVACR duty pumps, booster and irrigation pumps, dishwasher and part washer pumps, watering and de-watering pumps, and other commercial duty pumping applications.
HVACR RESCUE Special Application Commercial Pump Single Phase Open Drip-Proof (ODP) C-Face HVACR OEM APPLICATIONS: For use on chiller, condensate, and other HVACR duty pumps, booster and irrigation pumps, dishwasher and part washer pumps, watering and de-watering pumps, and other commercial duty pumping applications. FEATURES: 'RXEOH 6HDOHG %DOO %HDULQJV /RFNHG 'ULYH (QG %HDULQJ +] 0RWRUV KDYH 6 ) RQ +] &ODVV % ,QVXODWLRQ &RQWLQXRXV 'XW\ & $PELHQW ) $VVHPEO\ 5HYHUVLEOH 5RWD
HVACR RESCUE HVACR OEM Special Application Carbonator Pump Single Phase, Open Drip-Proof (ODP) Split Phase APPLICATIONS: Designed end shield with extended hub and short slotted shaft for close coupling carbonator pump to motor. )RU &DUERQDWRU 'XW\ 2QO\ 5HYHUVLEOH 5RWDWLRQ $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU 7KUHDGHG &RQGXLW +XE $OO %DOO %HDULQJ &RQVWUXFWLRQ *UHHQ *URXQG /HDG 6SHFLDO 6ORWWHG 6KDIW Resilient Base HP RPM Voltage Frame Catalog Number SF Total Length Ship Wt.
HVACR RESCUE Split Phase Hot Water Circulating Pump Open Drip-Proof (ODP) HVACR OEM APPLICATIONS: Designed to meet manufacturer’s requirements for use on hot water circulating pumps. FEATURES: 3DLQWHG 5HG 7R ,QGLFDWH +RW :DWHU 8VDJH & $PELHQW 5HYHUVLEOH 5RWDWLRQ 5HVLOLHQW +XE 5LQJV 6SHFLDO %DODQFH )RU 4XLHW 2SHUDWLRQ &ODVV % ,QVXODWLRQ 530 $XWRPDWLF 5HVHW 7KHUPDO 2YHUORDG 3URWHFWRU 6OHHYH %HDULQJV +DYH $OO $QJOH 7KUXVW 6\VWHP 8QLWV 0DWFK 2(0 3HUIRUPDQFH $QG 0HFKDQLFDO )HDWXUHV 6OHHYH
HVACR RESCUE HVACR OEM Special Application Commercial Pump Three Phase Totally Enclosed, Fan Cooled (TEFC) C-Face APPLICATIONS: For use on chiller, condensate, and other HVACR duty pumps, booster and irrigation pumps, dishwasher and part washer pumps, watering and de-watering pumps, and other commercial duty pumping applications. 7RWDOO\ (QFORVHG 'RXEOH VHDOHG EDOO EHDULQJV RQ DOO )UDPH FRPPHUFLDO GXW\ SXPS PRWRUV Double shielded ball bearings on all other motors. &RQWLQXRXV 'XW\ +]
HVACR RESCUE Special Application Commercial Pump Three Phase Totally Enclosed, Fan Cooled (TEFC) C-Face (continued) HVACR OEM Ship Wt. Full Load Eff. Max.
HVACR RESCUE HVACR OEM Special Application Commercial Pump Three Phase Totally Enclosed, Fan Cooled (TEFC) C-Face (continued) RPM Voltage Frame Catalog Number Base (Feet) SF Total Length Ship Wt. Full Load Eff. Max.
HVACR RESCUE Special Application Commercial Pump Three Phase Open Drip-Proof (ODP) C-Face HVACR OEM APPLICATIONS: For use on chiller, condensate, and other HVACR duty pumps, booster and irrigation pumps, dishwasher and part washer pumps, watering and de-watering pumps, and other commercial duty pumping applications. FEATURES: & $PELHQW 6XLWDEOH IRU :\H 'HOWD VWDUW )UDPH DQG ODUJHU 1(0$ ®† ³&´ )ODQJH 0RXQWLQJ 6KDIW 7KUHDGV IRU - 0RXQW 81& $ 3UHPLXP 6 6 RQ - 0RXQW &
HVACR RESCUE HVACR HVACR OEM Special Application Commercial Pump Three Phase Open Drip-Proof (ODP) C-Face (continued) HP RPM Voltage Frame Catalog Number Base (Feet) SF Total Length Ship Wt. Dripcover Kit Max.
Close Coupled Pump Motors )RU VSHFL¿F UHTXLUHPHQWV RI FHQWULIXJDO SXPSV ZKHUH the pump impeller is mounted directly on the motor shaft. Horsepower: 1 – 60 HP Phase: Single and Three Phase RPM: 1800 and 3600 RPM (I¿FLHQF\ Standard, Energy DQG 3UHPLXP (I¿FLHQW Enclosure: Open Drip-Proof (ODP) Totally Enclosed, Fan Cooled (TEFC) Hazardous Location Mounting: Footed and Footless Shaft Types: JM JP Westcoast ® U.S.
HVACR RESCUE Special Application Close Coupled Pump Three Phase Totally Enclosed Fan Cooled (TEFC) NEMA A 3UHPLXP (I¿FLHQt HVACR OEM ®† APPLICATIONS: UTE4 )RU WKH VSHFL¿F UHTXLUHPHQWV RI FHQWULIXJDO SXPSV ZKHUH WKH SXPS LPSHOOHU LV PRXQWHG GLUHFWO\ RQ WKH PRWRU VKDIW 8VHG LQ GDPS GXVW\ RU GLUW\ HQYLURQPHQWV HVACR FEATURES: &ODVV ) ,QVXODWLRQ &ODVV % 5LVH $W )XOO /RDG 2Q +HUW] 6LQH :DYH 3RZHU &DVW ,URQ )UDPH 8S $OXPLQXP Rolled Steel 140 &DVW ,URQ (QG %UDFNHWV 8S $
HVACR RESCUE Special Application Close Coupled Pump Three Phase 7RWDOO\ (QFORVHG )DQ &RROHG 7()& (QHUJ\ (I¿FLHQW UT4 )RU WKH VSHFL¿F UHTXLUHPHQWV RI FHQWULIXJDO SXPSV ZKHUH WKH SXPS LPSHOOHU LV PRXQWHG GLUHFWO\ RQ WKH PRWRU VKDIW Used in damp, dusty or dirty environments.
HVACR RESCUE HVACR OEM Special Application Close Coupled Pump Three Phase 7RWDOO\ (QFORVHG )DQ &RROHG 7()& (QHUJ\ (I¿FLHQW APPLICATIONS: UT4 )RU WKH VSHFL¿F UHTXLUHPHQWV RI FHQWULIXJDO SXPSV ZKHUH WKH SXPS LPSHOOHU LV PRXQWHG GLUHFWO\ RQ WKH PRWRU VKDIW Used in damp, dusty or dirty environments.
HVACR RESCUE Special Application Close Coupled Pump Three Phase Open Dripproof (ODP) NEMA A 3UHPLXP (I¿FLHQW ®† DE1 )RU WKH VSHFL¿F UHTXLUHPHQWV RI FHQWULIXJDO SXPSV ZKHUH WKH SXPS LPSHOOHU LV PRXQWHG GLUHFWO\ RQ WKH PRWRU VKDIW Used where dirt and moisture are minimal. HVACR OEM APPLICATIONS: FEATURES: 2 5 25 Note 06 Note 14 "C" Dim. (inches) 14.8 14.8 14.8 19.1 14.8 14.8 17.4 14.8 14.8 20.5 14.8 17.4 17.4 17.8 16.1 16.1 20.5 20.5 19.3 17.4 17.8 17.8 27.4 17.8 17.8 19.3 19.3 28.1 23.1 23.
HVACR RESCUE HVACR OEM Special Application Close Coupled Pump Three Phase 2SHQ 'ULSSURRI 2'3 (QHUJ\ (I¿FLHQW APPLICATIONS: FD4 )RU WKH VSHFL¿F UHTXLUHPHQWV RI FHQWULIXJDO SXPSV ZKHUH WKH SXPS LPSHOOHU LV PRXQWHG GLUHFWO\ RQ WKH PRWRU VKDIW Used where dirt and moisture are minimal.
HVACR RESCUE Special Application Close Coupled Pump Three Phase 2SHQ 'ULSSURRI 2'3 (QHUJ\ (I¿FLHQW (continued) HVACR OEM FD4 JP Shaft - Footed 10 20 30 50 SF 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.25 "C" Dim. (inches) 17.8 18.5 18.5 20.5 20.5 20.5 20.5 21.6 21.6 23.1 23.1 27.6 27.4 27.4 27.4 28.1 28.1 28.6 28.6 28.6 28.6 28.6 28.6 30.4 30.4 30.4 30.4 Ship Wt. Full Load Full Load (lbs) Eff. Amps 32 82.
HVACR RESCUE HVACR OEM Special Application Close Coupled Pump Single Phase, Totally Enclosed Fan Cooled (TEFC) APPLICATIONS: UTM4, UTM1 )RU WKH VSHFL¿F UHTXLUHPHQWV RI FHQWULIXJDO SXPSV ZKHUH WKH SXPS LPSHOOHU LV PRXQWHG GLUHFWO\ RQ WKH PRWRU VKDIW Used where dirt and moisture are minimal. &ODVV ) ,QVXODWLRQ ([WUXGHG $OXPLQXP )UDPH 2YHUVL]HG %DOO %HDULQJV Z /RFNHG 6KDIW (QG &RQVWUXFWLRQ 5HYHUVLEOH 5RWDWLRQ ) $VVHPEO\ 3RVLWLRQ $OXPLQXP (QG 6KLHOGV ZLWK 6WHHO %HDULQJ ,QVHUWV 6KDIW
HVACR RESCUE Special Application Close Coupled Pump Single Phase Open Dripproof (ODP) HVACR OEM APPLICATIONS: )RU WKH VSHFL¿F UHTXLUHPHQWV RI FHQWULIXJDO SXPSV ZKHUH WKH SXPS LPSHOOHU LV PRXQWHG GLUHFWO\ RQ WKH PRWRU VKDIW Used where dirt and moisture are minimal. FEATURES: &ODVV ) ,QVXODWLRQ 5ROOHG 6WHHO )UDPH 2YHUVL]HG %DOO %HDULQJV Z /RFNHG 6KDIW (QG &RQVWUXFWLRQ 5HYHUVLEOH ) $VVHPEO\ 3RVLWLRQ 6KDIW 6OLQJHU 2Q 3XOOH\ (QG /LIWLQJ 3URYLVLRQV )UDPH 8S -0 6KDIW )RU 0HFKDQLFDO 6HDO
HVACR RESCUE APPLICATIONS: Kit designed for conversion of off-the-shelf motors to accommodate a C-Flange Mount.
HVACR RESCUE C-Face Kits HVACR OEM APPLICATIONS: Kit designed for conversion of off-the-shelf motors to accommodate a C-Flange Mount.
HVACR RESCUE HVACR OEM D-Flange Kits APPLICATIONS: Kit designed for conversion of off-the-shelf motor to accommodate a D-Flange Mount.
HVACR RESCUE Dripcover Kits HVACR OEM APPLICATIONS: Provides protection to the motor in a vertical shaft down position.
HVACR RESCUE HVACR OEM Cast Iron Conversion Kits APPLICATIONS: For severe environments where all Cast Iron construction is required.
HVACR RESCUE Brake Kits HVACR OEM APPLICATIONS: Adjustable Motor Bases and Slide Rails Kits.
TERMS && TERMS CONDITIONS CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION GUIDE INDEX Terms & Conditions of Sale 1LGHF 0RWRU &RUSRUDWLRQ UHIHUUHG WR KHUHLQ DV WKH ³6HOOHU´ DQG WKH FXVWRPHU RU SHUVRQ RU HQWLW\ SXUFKDVLQJ JRRGV ³*RRGV´ IURP 6HOOHU LV UHIHUUHG WR DV WKH ³%X\HU ´ 7KHVH 7HUPV DQG &RQGLWLRQV DQ\ SULFH OLVW RU VFKHGXOH TXRWDWLRQ DFNQRZOHGJPHQW RU LQYRLFH IURP 6HOOHU UHOHYDQW WR WKH VDOH RI WKH *RRGV DQG DOO GRFXPHQWV LQFRUSRUDWHG E\ VSHFL¿F UHIHUHQFH KHUHLQ RU WKHUHLQ FRQVWLWXWH WKH FRPSOHWH
TERMS & CONDITIONS Motor Terminology Guide It is important to select the motor that will help assure optimum performance of the appliance or equipment to be driven. To do this, a motor must be selected that is capable of starting the equipment, bringing it up to operating speed, and driving it at the necessary loading speed as long as required without excessive heating.
TERMS & CONDITIONS TERMINOLOGY TERMINOLOGY GUIDE GUIDE MOTOR SELECTION GUIDE INDEX Motor Terminology Guide Enclosure (Encl). The motor’s housing. Types: Motor Speeds Open. Ventilation openings in the shell and/or end shields which permit passage of external air over and around the windings of the motor. Used indoors, in fairly clean locations. Synchronous. The theoretical maximum speed at which an induction-type motor can operate.
TERMS & CONDITIONS Motor Terminology Guide Mounting (MTG) )DFH RU ÀDQJH 6KDIW HQG HQG FRYHU KDV D ÀDW PRXQWLQJ surface, machined to NEMA standard dimensions with holes to allow easy, secure mounting to the housing of the unit or appliance. Commonly used on jet pumps, oil burners and gear reducers. Stud. Motor has bolts extending from front or rear, by which it is mounted. Often used on small, direct drive fans and blowers. Yoke.
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION SELECTION GUIDE GUIDE INDEX Motor Selection Guide Instructions How to Use this Selection Guide: 1. Measure the diameter of the motor if not known. 2. Check the RPM of the motors; (7200 divided by the number of poles or coil windings for 60 Hz Applications) 3ROHV 3ROHV 3ROHV 3ROHV WR 530 WR 530 WR 530 WR 530 3. Measure the length of the stack of the stator to determine horsepower.
TERMS & CONDITIONS Motor Selection Guide 3.3" Diameter HP Amps Iron Stack Speed Shaft Type Motor Type Enclosure Catalog Number 4 1550 2W 0.2 0.500 1 0.250 Shd Pl Unit Bearing TEAO 2102 4 1550 4W 0.5 0.500 1 0.250 Shd Pl Unit Bearing TEAO 2103 4 1550 4W 0.5 0.500 1 0.250 Shd Pl Unit Bearing TEAO 2115 4 1550 5W 0.6 0.500 1 0.250 Shd Pl Unit Bearing TEAO 2119 4 1550 5W 0.6 0.500 1 0.250 Shd Pl Unit Bearing TEAO 2120 4 1550 6W 0.6 0.
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION SELECTION GUIDE GUIDE INDEX Motor Selection Guide 5.0" Diameter 115 Volts Iron Stack Speed Shaft Type Motor Type Enclosure Catalog Number 1.8 0.750 3 0.500-DBL PSC Room A/C OAO 3996 2.3 1.000 2 0.500-DBL PSC Room A/C OAO 1238 1.2 1.250 3 0.500 PSC Direct Drive Fan/Blower OAO 8956 1/10 5.2 1.500 1 0.500 Shd Pl Condenser Fan ODPAO 721P 1/6 5.4 1.500 1 0.500 Shd Pl Condenser Fan ODPAO 722P 1550 1/10 3.8 1.
TERMS & CONDITIONS Motor Selection Guide 5.0" Diameter Speed Shaft Type Motor Type Enclosure 1/20 1.1 1.000 1 0.375 PSC Condenser Fan ODPAO 1775P 1/15 1.9 1.250 1 0.375 PSC Condenser Fan ODPAO 1779P 1550 1/10 2.6 1.000 1 0.500 Shd Pl Condenser Fan ODPAO 721P 1550 1/8 0.8 1.000 1 0.500 PSC Condenser Fan OAO 1675 4 1625 1/4 1.4 1.000 1 0.500 PSC Condenser Fan ODP 3042 4 1625 1/4 1.9 1.000 1 0.500 PSC Condenser Fan ODP 8330 4 1550 1/20 1.
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION SELECTION GUIDE GUIDE INDEX Motor Selection Guide 5.6" Diameter 115 Volts Iron Stack 0.750 Speed 1 Shaft 0.500 Type Spl Phs Motor Type Oil Burner Enclosure TENV 2.4 0.750 1 0.500 Spl Phs Oil Burner TENV 2097 2.4 1.000 1 0.500 Spl Phs Oil Burner TENV 3083 1/3 4.8 1.500 1 0.500 Spl Phs Oil Burner TENV 2319 3450 1/2 8.6/4.3 1.500 1 0.500 CS/CR Belted Fan/Blower ODP 298 3450 1/4 3.7 2.000 1 0.
TERMS & CONDITIONS Motor Selection Guide 5.6" Diameterr (continued) Poles RPM HP Amps Iron Stack Speed Shaft Type Motor Type Enclosure Catalog Number 1/3 5.3 2.000 4 0.500 PSC Direct Drive Fan/Blower OAO 1410 1075 3/4 11.7 2.250 4 0.500 PSC Direct Drive Fan/Blower OAO 3340 6 1075 1/2 6.5 2.500 3 0.500 PSC Direct Drive Fan/Blower OAO 1865 6 1075 3/4 9.5 2.500 3 0.500 PSC Direct Drive Blower OAO 8904 6 1075 3/4 10.6 2.750 4 0.
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION SELECTION GUIDE GUIDE INDEX Motor Selection Guide 5.6" Diameterr (continued) 208-230 Volts Poles RPM HP Amps Iron Stack Speed Shaft Type Motor Type Enclosure Catalog Number 4 1500 1/6 0.8 0.750 1 0.500 PSC Condenser Fan TEAO 3405 4 1550 1/6 1.1 0.750 1 0.500 PSC Condenser Fan TEAO 6128 4 1550 1/6 1.4 1.000 1 0.500 PSC Condenser Fan ODPAO 1645 4 1625 1/4 1.4 1.250 1 0.
TERMS & CONDITIONS Motor Selection Guide 5.6" Diameterr (continued) HP Amps Iron Stack Speed Shaft Type Motor Type Enclosure Catalog Number 6 1075 1/4 1.5 1.250 1 0.500 PSC Condenser Fan TEAO 1876 6 1075 1/4 1.5 1.250 1 0.500 PSC Condenser Fan TEAO 1860 6 1100 1/4 1.7 1.250 1 0.500 PSC Condenser Fan TEAO 3404 6 1075 1/4 1.9 1.250 3 0.500 - DBL PSC Room A/C ODPAO 3134 6 1075 1/4 1.5 1.250 3 0.
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION SELECTION GUIDE GUIDE INDEX Motor Selection Guide 5.6" Diameterr (continued) 208-230 Volts (continued) HP Amps Iron Stack Speed Shaft Type Motor Type Enclosure Catalog Number 1075 1/2 2.9 3.000 2 0.500 PSC Condenser Fan TEAO 8671 1075 3/4 4.7 3.000 2 0.500 PSC Condenser Fan TEAO 1879 6 1075 1 5.6 3.000 3 0.500 PSC Direct Drive Fan/Blower OAO 8907 6 1100 1 6.0 3.000 4 0.
TERMS & CONDITIONS Motor Selection Guide 5.6" Diameterr (continued) HP Amps Iron Stack Speed Shaft Type Motor Type Enclosure Catalog Number 6 1075 1/3 2.4/1.2 2.000 1 0.500 PSC Comm Cond Fan TEAO 6727 6 1075 1/2 2.8/1.4 2.500 1 0.500 PSC Comm Cond Fan TEAO 7475 6 1075 1/2 3.2/1.6 2.500 1 0.500 PSC Condenser Fan TEAO 2201 6 1140 1 3.5/1.7 2.750 1 0.500 3 Phs Comm Cond Fan OPDAO 1326 6 1075 3/4 4.6/2.3 3.000 1 0.
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION SELECTION GUIDE GUIDE INDEX Motor Selection Guide 6.3" Diameter 115 Volts Amps Iron Stack Speed Shaft Type Motor Type Enclosure Catalog Number 1/3 5.6 1.000 1 0.500 Spl Phs Evap Cooler ODP 6764 1/2 8.2 1.125 1 0.500 Spl Phs Evap Cooler ODP 6768 1725 1/3 5.8 1.125 1 0.500 Spl Phs Belted Fan/Blower ODP 4253 4 1725 1/4 5.0 1.125 1 0.500 Spl Phs Direct Drive Fan/Blower TEAO 6326 4 1725 1/2 7.9 1.375 1 0.
TERMS & CONDITIONS Motor Selection Guide 6.3" Diameterr (continued) Speed Shaft Type Motor Type Enclosure Catalog Number 1/2 7.4/3.7 1.500 1 1/2 8.0/4.0 1.625 1 0.625 Cap St Belted Fan/Blower ODP 1790 0.625 Spl Phs Belted Fan/Blower ODP 1725 1/2 8.0/4.0 1.625 4114 1 0.625 Cap St General Purpose TEFC T12C2J 1725 3/4 11.4/5.7 2.000 1 0.625 Cap St Belted Fan/Blower ODP 1893 4 1725 3/4 4 1725 3/4 11.2/5.6 2.000 1 0.
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION SELECTION GUIDE GUIDE INDEX Motor Selection Guide 6.3" Diameterr (continued) 208-230/460 Volts HP Amps Iron Stack Speed Shaft Type Motor Type Enclosure Catalog Number 1725 1/2 4.5 1.500 2 0.500 Spl Phs Evap Cooler ODP 6795 1725 1/2 4.8 1.750 1 0.500 Spl Phs Evap Cooler ODP 6766 4 1725 3/4 5.4 1.750 1 0.500 Spl Phs Evap Cooler ODP 6771 4 1725 1/2 4.6 1.750 2 0.
TERMS & CONDITIONS Index Sorted by Catalog Number PAGE# CATALOG# PAGE# CATALOG# 1042 1057 1089 1090 1093 1098 1099 1100 1105 1124 1125 1128 1129 1139 1140 1145 1146 1152 1158 1161 1173 1177 1180 1182 1184 1186 1187 1191 1192 1195 1197 1198 1208 1209 1210 1211 1213 1218 1219 1238 1240 1242 1243 1244 1247 1254 1255 1256 1257 1258 46 136 55 26,45 32 35 35 17 26 27,42 18,49 21 56 17 38 58 58 17,47 38 26,49 37 37 41,42 42 38 47 47 59 18,45 59 55 35 60 88 19,45 19,44 47 19,44 38 42 47 47 47 47 47 23,37 59 1
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION GUIDE INDEX INDEX Index Sorted by Catalog Number CATALOG# 1899 1900 1901 1902 1903 1917 1924 1928 1931 1933 1935 1937 1940 1954 1960 1961 1962 1964 1971 1972 1973 2097 2102 2103 2108 2109 2110 2111 2112 2113 2114 2115 2116 2117 2118 2119 2120 2122 2123 2124 2125 2126 2127 2128 2129 2130 2131 2132 2133 2134 PAGE# 59 59 21,31 25,34 25,34 61,101 61,101 61,101 61,101 61,101 61,101 61,101 61,101 13,45 19,45 19,44 44 19,45 48 48 48 57 28 28 28 28 28 28 28
TERMS & CONDITIONS Index Sorted by Catalog Number PAGE# CATALOG# PAGE# CATALOG# 8200 8230 8233 8330 8331 8431 8438 8461 8488 8489 8490 8491 8493 8498 8525 8537 8665 8666 8667 8670 8671 8673 8674 8675 8725 8726 8868 8904 8905 8906 8907 8944 8945 8947 8952 8955 9034 9035 9036 9377 9624 9628 9632 9641 9648 9654 9656 9657 9662 9664 52 33 13,37 25,32 25,32 37 53 55 55 55 55 55 55 55 45 36 33 33 33 35 35 34 34 35 47 47 37 48 48 48 48 49 49 49 43 43 51 51 51 50 29 29 29 29 29 29 2,29 29 2,29 2,29 9735 9993
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION GUIDE INDEX INDEX Index Sorted by Catalog Number CATALOG# PAGE# CATALOG# PAGE# CATALOG# PAGE# CATALOG# PAGE# 958192 958193 958194 958195 964220 964221 964222 964223 964224 964225 964226 964227 964252 967059 967060 967061 967062 967063 967064 967065 967066 967067 969573 969574 969575 969578 969579 1004H 1127P 1139VG 1221P 1278H 1295H 1338P 1468P 1469P 1470P 1471P 1542C 1775P 1779P 1817H 1818H 1818VG 1819H 1819VG 1820H 1820VG 1821H 1821VG 157 157
TERMS & CONDITIONS Index Sorted by Catalog Number D15P2H D15P3D D15P3G D15P3H D15V1B D15V2B D15V3B D16B3N4Z9 D1C1J D1C1J9 D1C2J14 D1C2JCR D1C2JH D1C2JH9 D1C2P18Z D1C3JH D1CA1J9 D1CA2J14 D1CA2JH D1CA2JH9 D1CA3JH9 D1CM1J D1CM2J14 D1CM2JH D1E2DHZ D1E4D D1P2D D1P2G D1P2H D1P3D D1P3G D1P3H D1S1A D1S2AH D1S2AH9 D1S2AHC D1V2B D1V3B D200E4F D200P1FS D200P1GS D200P2F D200P2FS D200P2G D200P2GS D200P3F D200P3G D200V2C D20E4D D20E4G PAGE# 108 108 108 108 128 128 128 86 89 88 89 91 89 88 89 89 88 89 89 88 88 89 89 8
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION GUIDE INDEX INDEX Index Sorted by Catalog Number CATALOG# D32C1JHC D32C2J14 D32C2J149 D32C2J14C D32C2JCR D32C2JH D32C2P18Z D32CA1JH9 D32CA2JCR D32CA2JH D32CA2JH9 D32CM1JH D32CM2J14 D32CM2JH D32E4G D32P1D D32P1G D32P2B2 D32P2D D32P2G D32P2H D32P3D D32P3G D32S1AHC D32S2ACR D32S2AH9 D32SA1AH9 D32V2B D32V3B D34B2N9 D34C1J D34C2J D34C2J9 D34C2JC D34C3JH D34CA1J9 D34CA2J D34CA2JCR D34CA2JH9 D34CA3J9 D34CM1J D34CM2J D34S1B D34S2A D34S2A9 D34S2ACR D34S3AH D34S
TERMS & CONDITIONS Index Sorted by Catalog Number PAGE# CATALOG# DJ3E2DM DJ3E2DP DJ3P1DM DJ3P2DM DJ3P2HM DJ3P3DM DJ40E1DM DJ40E1DP DJ40E1GM DJ40E1GP DJ40E2DP DJ40E2EM DJ50E1EM DJ50E1EP DJ50E2EM DJ50E2EP DJ5C1K18M DJ5C1K18P DJ5C2K18M DJ5C2K18P DJ5C2K21M DJ5E1DM DJ5E1DP DJ5E1GM DJ5E1HM DJ5E2DM DJ5E2DP DJ5E2GM DJ5P1DM DJ5P1HM DJ5P2DM DJ5P2HM DJ5P3DM DJ60E1EM DJ60E1EP DJ7C1K18M DJ7C1K21M DJ7C1K21P DJ7C2K21M DJ7C2K21P DJ7E1DM DJ7E1DP DJ7E1GM DJ7E2DJ DJ7E2DM DJ7E2DP DJ7E2GM DJ7P1DM DJ7P2DM DJ7P2HM PAGE# CATA
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION GUIDE INDEX INDEX Index Sorted by Catalog Number CATALOG# FD13BM2PZYR FD13CM2P FD13CM2PCR FD13SM2DZYR FD1AA4KCR FD1CA1PZ FD1CA2J FD1CA2J9 FD1CM2P14 FD1CM2PCR FD1CM2PZ FD1SM2DZYR FD2CA1P14 FD2CM2P18 FD2CM2PHZ FD32CA1P14 FD32CA2P FD32CM2P14 FD32CM2PCR FD32CM2PHZY FD32SM2DZYR FD34BA2P FD34CA1PZ FD34CM2P FD34CM2PCR FD34CM2PZY FD34CM2PZYR FD34SM2DZYR FD3CA1K14 FD3CM2K18 FD5CM1K18Z FD5CM2K18 FD5CM2K21 FD7CM1K18Z FD7CM2K21 FDU10CM2K21 FDU10CM2K21C FDU2CM2P18Z
TERMS & CONDITIONS Index Sorted by Catalog Number PAGE# CATALOG# H40P3E H40P3G H40P3H H40T2B H40V1BS H40V2B H40V3B H50P1ES H50P1GS H50P1HS H50P2E H50P2ES H50P2G H50P2GS H50P2H H50P2HS H50P3E H50P3G H50P3H H50T2B H50V1BS H50V2B H50V3B H5E4D H5P1D H5P1G H5P1H H5P2D H5P2G H5P2H H5P3D H5P3G H5P3H H5T2B H5V1BC H5V2BC H5V3BC H60P1ES H60P1GS H60P1HS H60P2E H60P2ES H60P2G H60P2GS H60P2H H60P2HS H60P3E H60T2B H60V1BS H60V2B PAGE# 122 122 122 127 126 126 126 122 122 122 122 122 122 122 122 122 122 122 122 127 12
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION GUIDE INDEX INDEX Index Sorted by Catalog Number CATALOG# HVW20PK9G HVW20PK9H HVW20PL36C HVW20PL36G HVW20PL36H HVW20PL9C HVW20PL9G HVW20PL9H HVW20V2E HVW20V2E8 HVW20V2G HVW20V2H HVW20V3E HVW20V3G HVW20V3H HVW25PK36C HVW25PK36G HVW25PK36H HVW25PK9C HVW25PK9G HVW25PK9H HVW25PL36C HVW25PL36G HVW25PL36H HVW25PL9C HVW25PL9G HVW25PL9H HVW25V2E HVW25V2E8 HVW25V2G HVW25V2H HVW25V3E HVW25V3G HVW25V3H HVW2PK36C HVW2PK36G HVW2PK36H HVW2PK9C HVW2PK9G HVW2PK9H HVW2
TERMS & CONDITIONS Index Sorted by Catalog Number PAGE# CATALOG# HW15V2E HW15V2E2 HW15V2G HW15V2H HW15V3E HW15V3G HW15V3H HW20PK36C HW20PK36G HW20PK36H HW20PK9C HW20PK9G HW20PK9H HW20PL36C HW20PL36G HW20PL36H HW20PL9C HW20PL9G HW20PL9H HW20V2E HW20V2E2 HW20V2G HW20V2H HW20V3E HW20V3G HW20V3H HW25PK36C HW25PK36G HW25PK36H HW25PK9C HW25PK9G HW25PK9H HW25PL36C HW25PL36G HW25PL36H HW25PL9C HW25PL9G HW25PL9H HW25V2E HW25V2E2 HW25V2G HW25V2H HW25V3E HW25V3G HW25V3H HW2PK36C HW2PK36G HW2PK36H HW2PK9C HW2PK9G P
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION GUIDE INDEX INDEX Index Sorted by Catalog Number CATALOG# HW5V2E HW5V2E2 HW5V2G HW5V2H HW5V3E HW5V3G HW5V3H HW60PK36C HW60PK36G HW60PK36H HW60PK9C HW60PK9G HW60PK9H HW60PL36C HW60PL36G HW60PL36H HW60PL9C HW60PL9G HW60PL9H HW60V2E HW60V2G HW60V2H HW60V3E HW60V3G HW60V3H HW75PK36C HW75PK36G HW75PK36H HW75PK9C HW75PK9G HW75PK9H HW75PL36C HW75PL36G HW75PL36H HW75PL9C HW75PL9G HW75PL9H HW75V2E HW75V2G HW75V2H HW75V3E HW75V3G HW75V3H HW7PK36C HW7PK36G HW7PK3
TERMS & CONDITIONS Index Sorted by Catalog Number PAGE# CATALOG# U10P1DC U10P1G U10P1GC U10P1H U10P2D U10P2DC U10P2G U10P2GC U10P2H U10P3D U10P3DC U10P3G U10P3H U10R9C U10V1B U10V2B U10V3B U12S1AC U12S2AC U12S2ACR U12S2GC U12S2GCR U12S3AC U12S3ACR U12T2BCR U13S2AC U13S2ACR U13S2GC U13S3AC U13T2BCR U14S2AC U14S2ACR U14S2GC U15D10C U15E1DCR U15E1GCR U15E2DCR U15E2GCR U15L9C U15P1AF U15P1D U15P1DC U15P1DFC U15P1G U15P1GC U15P1H U15P2D U15P2DC U15P2G U15P2H PAGE# 117,140 115 117,140 115 115 117,140 115 117
TERMS & CONDITIONS TERMINOLOGY GUIDE MOTOR SELECTION GUIDE INDEX INDEX Index Sorted by Catalog Number CATALOG# U32P1G U32P1H U32P2D U32P2DC U32P2G U32P2GC U32P2H U32P3D U32P3DC U32P3G U32P3GC U32P3H U32R9C U32S1AFC U32S2AFC U32S2AFCR U32S2GFC U32V1BC U32V2BC U32V3BC U34S1AC U34S1ACR U34S2AC U34S2ACR U34S2GC U34S2GCR U34S3AC U34S3ACR U34S3DC U34T2BCR U3D10C U3E1A14CR U3E1DCR U3E1DKR U3E2DCR U3E3DCR U3E4D U3L9C U3P1A14C U3P1D U3P1DC U3P1DF U3P1DK U3P1G U3P1GF U3P1H U3P1HF U3P2D U3P2DC U3P2DK PAGE# 113 11
TERMS & CONDITIONS Index Sorted by Catalog Number PAGE# 145 146 144 144 144 144 150 150 150 150 146 145 146 145 146 146 145 146 144 144 144 144 124 124 124 124 102 124 124 7 7 7 7 61 61 61 156 156 156 156 156 156 MOTOR SELECTION GUIDE INDEX INDEX UJ5E2DM UJ5E2DP UJ5P1BM UJ5P1GM UJ5P2BM UJ5P2GM UJ7C1K21M UJ7C1K21P UJ7C2K21M UJ7C2K21P UJ7E1BP UJ7E1DFM UJ7E1DJ UJ7E1DM UJ7E1DP UJ7E2DJ UJ7E2DM UJ7E2DP UJ7P1BM UJ7P1GM UJ7P2BM UJ7P2GM UN12V2AC UN12V3BC UN13V2BC UN1V2AFC UN32S4CKR UN34V2AC UN34V3BC US5460 US54
NEMA Dimension Guide Dimensions for AC Foot-Mounted Motors with Single Straight-Shaft Extension Frame 42 48 48H 56 56H 143T 145T 182 184 182T 184T 213 215 213T 215T 254U 256U 254T 256T 284U 286U 284T 286T 284TS 286TS 324U 326U 324US 326US 324T 326T 324TS 326TS 364U 365U 364US 365US 364T 365T 364TS 365TS 404U 405U 404US 405US 404T 405T 404TS 405TS 444U 445U 444US 445US 444T 445T 447T 449T 444TS 445TS 447TS 449TS 5004 5004G 5004S 5004SS 5006L 5006S 5006MS 5008 5008G 5008L 5008S 5008MS 5008SS A Max — — D 2.
NEMA Dimension Guide (continued) JP Shaft Frame 143 145 182 184 213 215 254 256 284 286 324 326 364 365 AH U EM EL EN AK R Keyseat ES Min. S 7.313 0.8745 1.0000 1.156 3/8-16 x .75 4.500 0.771 1.65 0.188 7.313 0.8745 1.0000 1.250 3/8-16 x .75 4.500 0.771 1.65 0.188 8.125 1.2495 1.3750 1.750 3/8-16 x .75 8.500 1.112 1.65 0.250 8.125 1.2495 1.3750 1.750 1/2-13 x 1.00 8.500 1.112 2.53 0.250 8.125 1.2495 1.3750 1.750 1/2-13 x 1.00 12.500 1.112 2.53 0.250 8.
Member of the following: Nidec Supports 1$7( &HUWL¿FDWLRQ Nidec Motor Corporation, © 2015; All Rights Reserved. U.S. MOTORS® is a registered trademark of Nidec Motor Corporation. Nidec Motor Corporation trademarks followed by the ® symbol are UHJLVWHUHG ZLWK WKH 8 6 3DWHQW DQG 7UDGHPDUN 2I¿FH HVACR400 03/15 8050 W. Florissant Avenue | St. Louis, MO 63136 Phone: 855- 487-6686 | Fax: 800-899-2887 www.usmotors.