Product data
USRobotics 
Command Reference
Fax Class 1 and Fax Class 1.0 Commands - 116
OK If the modem's transmit buffer becomes empty and the last 
transmitted character is was not NUL, the modem will turn off the 
transmit carrier, return to the command state, and report the OK 
result code. 
Reporting Current or Selected Values 
Command: +FTM?
Response: +FTM: <mod> 
Example:  +FTM: 98 For V.17 9600 bps. 
Reporting Supported Range of Parameter Values 
Command: +FTM=?
Response: +FTM: (<mod> range) 
Example: +FTM: 3,24,48,72,73,74,96,97,98,121,122,145,146 
+FRM - Receive Facsimile 
This command causes the modem to enter the receiver mode using the 
modulation defined below. 
Syntax 
+FRM=<mod> 
Defined Values 
<mod> Decimal number corresponding to the selected modulation mode 
and data rates shown in Table 4-2. 
Reporting Current or Selected Values 
Command: +FRM?
Response: +FRM: <mod>
Example:  +FRM: 98 For V.17 9600 bps. 
Reporting Supported Range of Parameter Values 
Command: +FRM=?
Response: +FRM: (<mod> range) 
Example: +FRM: 3,24,48,72,73,74,96,97,98,121,122,145,146 
Result Codes 
CONNECT Reported when the selected carrier is detected. 