EUROSTEAM/US STEAM TRAINING MANUAL MODELS ES1900, ES2100, ES4500, ES6100 EUROSTEAM/US STEAM 110 South Hampton Crowley, TX 76036 800-613-3874 EUROSTEAM.
EUROSTEAM/US STEAM SANITIZED FOR HEALTH - REDEFINED PRECAUTIONS KEEP THESE INSTRUCTIONS Read these instructions carefully before using the appliance and make sure that anyone using the machine is familiar with these instructions and warnings. KEEP FOR YOUR RECORDS. THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. PLEASE READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL BEFORE USING THIS VAPOR STEAM CLEANER.
EUROSTEAM SANITIZED FOR HEALTH - REDEFINED EUROSTEAM/US STEAM TRAINING MANUAL TABLE OF CONTENTS CONTENT PAGE SECTION I: UNIT INFORMATION….. ………………………………………….……. 4 TOOL USE GUIDE …………………………………………………………………….. 6 SECTION II: APPLICATION TIPS & PRECAUTIONS ……………………………... 9 SECTION III: THE ES4500 OPERATION & MAINTENANCE ……………….…… 13 ES2100 OPERATION…………………………………………………………………. 15 ES1900 OPERATION…………………………………………………………………. 16 ES6100 OPERATION………………………………………………………………….
EUROSTEAM/US STEAM SANITIZED FOR HEALTH - REDEFINED SECTION I: THE EUROSTEAM UNIT I. HOW TO START UP THE EUROSTEAM a) b) c) d) e) f) g) h) i) j) Make sure the unit is unplugged, plus the POWER switch is off. Remove the top cap. Fill unit with water using the filler bottle. Press gently down the bottle to release water through the spill proof cap or use funnel. Fill until ½‖ – 1‖ below top of tank. Hand-tighten the top cap (hand-tighten ONLY). Plug the unit into a grounded 120V outlet.
EUROSTEAM SANITIZED FOR HEALTH - REDEFINED V. WORK TECHNIQUES Work from the top down on any project so dirt will not fall on cleaned surfaces. Start with cleaning corners and other tight areas first with the nozzle and small brushes, working your way up to larger surfaces and brushes. PRE-STEAM Get in a habit of pre-steaming a surface if it is heavily soiled. At a 5‖ distance, shoot steam on surface from all directions for 10 seconds on HIGH PRESSURE.
EUROSTEAM/US STEAM SANITIZED FOR HEALTH - REDEFINED TOOL USE GUIDE TOOL APPLICATIONS 1 HOLE NOZZLE Use with Medium or High pressure where focused cleaning is needed. Tile grout, refrigerator, dishwasher, toilet bowls, corners, and crevices. Spray area with Vapormate use on Medium or High heat. 1 Hole Nozzle is also used with 1 inch brushes see 1 inch nylon and brass brushes. 1 INCH NYLON BRUSH Attach the 1 hole nozzle to the hose handle and then the brush to the nozzle.
EUROSTEAM SANITIZED FOR HEALTH - REDEFINED TOOL APPLICATIONS SMALL TRIANGULAR BRUSH: Use to get into corners. Attach the 3 hole nozzle to the hose handle and then the brush to the nozzle. Set the steam dial to medium pressure. Stovetops, kitchen countertops, kitchen or bathroom sinks, dishwasher interior, refrigerators, fiberglass or porcelain bathtubs, and glass shower doors: Use Vapormate on surface as you clean. Using med/high steam move across surface to be cleaned making sure to cover all areas.
EUROSTEAM/US STEAM SANITIZED FOR HEALTH - REDEFINED SECTION II: APPLICATION TIPS & PRECAUTIONS IX. DISTILLED WATER We recommend using de-mineralized or distilled water. This eliminates the possibility of creating hard water stains while you are cleaning and prevents excessive build-up of mineral deposits around the heating element in the tank. If you use tap water, get into the habit of flushing the tank every second week. (See water conditioning) X.
EUROSTEAM SANITIZED FOR HEALTH - REDEFINED Mist area with EUROSTEAM VAPORMATE Clean door molding with single-hole nozzle. Add 1-inch round nylon for light scrubbing. Starting from top of refrigerator, use a 3-hole nozzle with 3-inch round or 3-inch triangle. Clean all areas. Wipe cleaned area with cotton towel as you go. BATHROOM FAUCET AND FIXTURES Using the 1-hole nozzle, blow out around faucet and fixture detail areas.
EUROSTEAM/US STEAM SANITIZED FOR HEALTH - REDEFINED CARPETS Always VACUUM carpet first! Always TEST an area for discoloring before cleaning! Some carpets are made with vegetable dyes, which are not ―set‖ by heat — the color can bleed from heat and moisture. Man made carpet fibers melt at temperatures 300˚ and above. The heat from the vapor system does not melt the fibers, but it can change their shape at temperatures 185˚F-250˚F.
EUROSTEAM SANITIZED FOR HEALTH - REDEFINED Use large rectangular brush with diapered towel. Preheat towels and wipe with no steam. Wait a few minutes. To dry, use the triangle brush with 1 towel, without steam, and wipe with vertical and diagonal strokes. WALLS & CEILINGS NEVER USE BRUSHES WITHOUT A TOWEL ON PAINTED SURFACES! ALWAYS USE 2 TOWELS ON THE RECTANGULAR BRUSHES! WALLPAPER WASHABLE: Use rectangular or triangle brush with one towel. Preheat towels and wipe with no steam or low pressure.
EUROSTEAM/US STEAM SANITIZED FOR HEALTH - REDEFINED ALUMINUM: Use brass brush directly on the surface to remove dirt and to polish. Wipe with towel. BLINDS CAUTION! NOT RECOMMENDED FOR CLOTH BLINDS - DO NOT USE EXCESSIVE HEAT ON VINYL BLINDS! SLATS DUSTING: Open blinds and use 1-hole nozzle on medium to high pressure to blow dust onto a wipe cloth or on the window and wipe clean. DEEP CLEANING: Close blinds with top of slats facing you. Use triangle brush with one towel on low or medium pressure.
EUROSTEAM SANITIZED FOR HEALTH - REDEFINED SECTION III: THE ES4500 - CLEANING AND MAINTENANCE DRY VAPOR CLEANER, SANITIZER AND ADDITIVE APPLICATION STEAMER The ES4500 delivers the ―next generation‖ cleaning and sanitation solution. It utilizes ―Dry Steam‖ [only 6% water vapor] to efficiently clean and sanitize. The ES4500’s patent pending technology can apply cleaners, antimicrobial coatings and eco-friendly sanitation products with steam, enhancing their effectiveness.
EUROSTEAM/US STEAM SANITIZED FOR HEALTH - REDEFINED f) Turn Switch 2 - Steam Release to ―ON‖ [yellow light will be displayed when switch is in the ―on‖ position] g) ―Bleed‖ the system by using high pressure; [ES1900 & ES2100: press both switches on the hose handle: ES4500 turn Pressure Control knob to HIGH - all the way to the right] h) Press the trigger to remove water residue from the hose into towel for about 5 seconds. i) Wait until MAXIUM PRESSURE lights again before starting to clean.
EUROSTEAM SANITIZED FOR HEALTH - REDEFINED ES2100 Controls There are two sets of operator controls, the first set of three buttons are located on the front of the unit. 1. First button (1) heats the element in the pressure vessel. (Heating element button) 2. Second button (2) allows the steam to reach the hose. (Steam button) 3. Third button (3) is for water and steam combination. (Hot water button) 4. Green light illuminates when pressure is correct and machine is ready to use. 5.
EUROSTEAM/US STEAM SANITIZED FOR HEALTH - REDEFINED ES1900 Controls There are two sets of operator controls, the first set of two buttons are located on the front of the unit. 6. First button (1) heats the element in the pressure vessel. (Heating element button) 7. Second button (2) allows the steam to reach the hose. (Steam button) 8. Green light (4) illuminates when pressure is correct and machine is ready to use. 9.
EUROSTEAM SANITIZED FOR HEALTH - REDEFINED ES6100 Controls There are two sets of operator controls, the first set of two buttons are located on the front of the unit. 10.First button (1) heats the element in the pressure vessel. (Heating element button) 11.Second button (2) allows the steam to reach the hose. (Steam button) 12.Green light (4) illuminates when pressure is correct and machine is ready to use. 13.
EUROSTEAM/US STEAM SANITIZED FOR HEALTH - REDEFINED The ES6100, ES1900, and ES2100 are designed for minimum maintenance, and no user adjustments should be necessary. Certain parts may need replacement after prolonged use. If there is a need for service, only Eurosteam service personnel or authorized Eurosteam service agents should perform the work. Always use water with a low mineral count that meets the standards outlined in the Water Conditioning section of this manual.
EUROSTEAM SANITIZED FOR HEALTH - REDEFINED US Steam Maintenance And Water Recommendations Water Conditioning: It is essential to supply US Steam Systems with clean low mineral content water to help prevent scale build-up. Even though US Steam Systems are engineered to minimize scale formation, scale development depends on the hardness of your water and the number of hours the equipment operates. Most tap water sources are full of minerals, which form scale during operation.
EUROSTEAM/US STEAM SANITIZED FOR HEALTH - REDEFINED EUROSTEAM/US STEAM PRODUCT WARRANTY STANDARD TERMS AND CONDITIONS TWELVE MONTHS LIMITED WARRANTY Austin K Inc DBA Eurosteam, US Steam (EUS) warrants that the EUROSTEAM/US STEAM Vapor Steam Systems and Cart (“System”) sold by the seller (“Seller”) will be free from defects in materials and workmanship for a period of eighteen (12) months from the date EUS receives the product warranty card, not to exceed Twenty (18) months from the date of sale.